文献速递乳腺MR

3T多参数MRI与乳腺癌分子亚型之间是否存在相关性

Is there a correlation between 3T multiparametric MRI and molecular subtypes of breast cancer?
PubMed 文献 · Eur J Radiol · 2018-09-24

本研究纳入433例患者(453个病灶),对乳腺影像报告和数据系统4-5类病灶行3T多参数MRI(动态增强、扩散加权成像和磁共振波谱),并按免疫组化定义的四种分子亚型分析MRI特征与分子亚型的相关性。结果显示部分MRI特征与分子亚型显著相关,多参数联合的ROC曲线下面积显著优于单一参数,但作者指出仅凭多参数MRI预测分子亚型仍需进一步研究。

要点

  • 三阴性肿瘤体积较其他亚型合并更大,Luminal-B肿瘤体积更小。
  • Luminal-A型ADC值更高,三阴性肿瘤总胆碱信噪比更高。
  • 多参数MRI联合特征的AUC显著优于单一参数。

核心结论

  • 部分MRI特征与乳腺肿瘤分子亚型之间存在显著相关性。
  • 多参数方法提高了MRI的诊断效能。
  • 作者指出,仅凭多参数MRI预测分子亚型仍需进一步研究。

研究设计与样本

  • 研究纳入有乳腺X线或超声发现乳腺病灶(BI-RADS 4-5类)的女性,行3T多参数MRI(动态增强、扩散加权成像和磁共振波谱)。
  • 评估乳腺癌组织学类型,并以免疫组化评估雌激素受体、孕激素受体、Ki-67状态和HER-2表达,定义Luminal-A、Luminal-B、HER2富集型和三阴性四种分子亚型。
  • 共纳入433例患者(453个病灶)。
  • 采用非参数检验(Kruskal-Wallis检验、k样本中位数相等检验和Mann-Whitney检验)、逻辑回归或方差分析及多变量分析,研究四种分子亚型与多参数MRI特征(病灶体积、边缘或分布、强化方式、ADC、动力学曲线类型和总胆碱信噪比)之间的相关性。
  • 最后行ROC分析检验多变量逻辑回归模型的诊断效能。

关键影像表现/征象

  • 与其他亚型合并相比,Luminal-B肿瘤体积更小,三阴性肿瘤体积更大。
  • 边缘与Luminal-A和Luminal-B显著相关。
  • 曲线类型与Luminal-A显著相关。
  • Luminal-A的ADC值更高。
  • 三阴性肿瘤的总胆碱信噪比更高。

诊断标准与关键数值

  • ROC分析显示,与单一参数相比,联合多个MRI特征时曲线下面积(AUC)显著提高。

局限性

  • 作者指出,仅凭多参数MRI预测分子亚型仍需进一步研究。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: To test whether 3 T multiparametric magnetic resonance imaging (mMRI) provides information related to molecular subtypes of breast cancer.

METHODS: Women with mammographic or US findings of breast lesions (BI-RADS 4-5) underwent 3 T mMRI (DCE, DWI and MR spectroscopy). The histological type of breast cancer was assessed. Estrogen-receptor (ER), progesterone-receptor (PgR), Ki-67 status and HER-2 expression, assessed by immunohistochemistry (IHC), defined four molecular subtypes: Luminal-A, Luminal-B, HER2-enriched and triple-negative. Non-parametric tests (Kruskal-Wallis, k-sample equality of medians, and Mann-Whitney), logistic regression or ANOVA, and a multivariate analysis were performed to investigate correlations between the four molecular subtypes and mMRI (lesion volume, margins or distribution, enhancement pattern, ADC, type of kinetic curve, and total choline (tCho) signal-to-noise-ratio (SNR)). A ROC analysis was finally performed to test the diagnostic power of a multivariate logistic regression model.

RESULTS: 433 patients (453 lesions) were considered. Volume was smaller in Luminal-B and larger in triple-negative tumours compared to the other subtypes combined. Margins were significantly correlated to Luminal-A and Luminal-B. The type of curve was significantly correlated to Luminal-A. ADC values were higher in Luminal-A. tCho SNR was higher in triple-negative tumours. The ROC analysis showed that the area under the curve (AUC) significantly improved when multiple MRI features were used compared to individual parameters.

CONCLUSIONS: A significant correlation was found between some MRI features and molecular subtypes of breast tumours. A multiparametric approach improved the diagnostic power of MRI. However, further research is needed in order to predict the molecular subtype on the sole basis of mMRI.

来源:Eur J Radiol,查看原文。版权归原作者所有。

引用

  1. Montemezzi S, Camera L, Giri MG, et al. Is there a correlation between 3T multiparametric MRI and molecular subtypes of breast cancer? Eur J Radiol. 2018. PMID: 30396643. doi:10.1016/j.ejrad.2018.09.024

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。