乳腺X线摄影中人工智能支持系统对乳腺癌检出效能的影响
该回顾性多阅片者多病例研究纳入240例乳腺X线摄影检查(100例癌症、40例假阳性召回、100例正常),由14名放射科医师分别在无AI支持和有AI支持条件下阅片。AI支持使AUC从0.87升至0.89(P=0.002),敏感度从83%升至86%(P=0.046),特异度有改善趋势(77% vs 79%,P=0.06),阅片时间无显著差异(146秒 vs 149秒,P=0.15)。
要点
- AI支持使放射科医师的AUC从0.87提高至0.89(P=0.002)。
- AI支持使敏感度从83%(83/100)提高至86%(86/100)(P=0.046)。
- 特异度有改善趋势(77% vs 79%,P=0.06),阅片时间无显著差异。
核心结论
- 放射科医师使用人工智能系统支持后,乳腺X线摄影的癌症检出效能提高,且未增加阅片时间。
研究设计与样本
- 回顾性、全交叉、多阅片者多病例研究(符合HIPAA),纳入240例2013至2017年间的筛查性数字乳腺X线摄影检查(中位年龄62岁,范围39-89岁),由14名符合《乳腺X线摄影质量标准法》资格的放射科医师分别在有和无AI支持条件下各阅片一次。
诊断标准与关键数值
- AI支持后AUC为0.89,无AI支持为0.87(P=0.002);敏感度AI支持86%(86/100),无AI支持83%(83/100)(P=0.046);特异度AI支持79%(111/140),无AI支持77%(108/140)(P=0.06);单用AI系统的AUC为0.89,与放射科医师平均AUC 0.87相似。
临床应用与阅片要点
- AI支持提供交互式决策支持(点击乳腺区域获得局部癌症可能性评分)、计算机检测异常的传统病灶标记以及基于检查的癌症可能性评分;放射科医师可参考这些信息进行BI-RADS评分和恶性概率判断,且不增加阅片时间。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
Purpose To compare breast cancer detection performance of radiologists reading mammographic examinations unaided versus supported by an artificial intelligence (AI) system. Materials and Methods An enriched retrospective, fully crossed, multireader, multicase, HIPAA-compliant study was performed. Screening digital mammographic examinations from 240 women (median age, 62 years; range, 39-89 years) performed between 2013 and 2017 were included. The 240 examinations (100 showing cancers, 40 leading to false-positive recalls, 100 normal) were interpreted by 14 Mammography Quality Standards Act-qualified radiologists, once with and once without AI support. The readers provided a Breast Imaging Reporting and Data System score and probability of malignancy. AI support provided radiologists with interactive decision support (clicking on a breast region yields a local cancer likelihood score), traditional lesion markers for computer-detected abnormalities, and an examination-based cancer likelihood score. The area under the receiver operating characteristic curve (AUC), specificity and sensitivity, and reading time were compared between conditions by using mixed-models analysis dof variance and generalized linear models for multiple repeated measurements. Results On average, the AUC was higher with AI support than with unaided reading (0.89 vs 0.87, respectively; P = .002). Sensitivity increased with AI support (86% [86 of 100] vs 83% [83 of 100]; P = .046), whereas specificity trended toward improvement (79% [111 of 140]) vs 77% [108 of 140]; P = .06). Reading time per case was similar (unaided, 146 seconds; supported by AI, 149 seconds; P = .15). The AUC with the AI system alone was similar to the average AUC of the radiologists (0.89 vs 0.87). Conclusion Radiologists improved their cancer detection at mammography when using an artificial intelligence system for support, without requiring additional reading time. Published under a CC BY 4.0 license. See also the editorial by Bahl in this issue.
引用
- Rodríguez-Ruiz A, Krupinski E, Mordang JJ, et al. Detection of Breast Cancer with Mammography: Effect of an Artificial Intelligence Support System. Radiology. 2018. PMID: 30457482. doi:10.1148/radiol.2018181371
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。