在胎儿结构筛查时使用三维超声评估胎盘脐带插入位置
本研究回顾性纳入216例单胎初产妇,于孕14至23周行三维超声测量胎盘脐带插入点距胎盘边缘的距离(PCI-D),分析其与胎盘特征及出生结局的关系。结果显示PCI-D与低置胎盘或前置胎盘相关(P=0.03),与出生体重z评分(P=0.09)和孕次(P=0.10)的关联未达统计学显著。作者认为PCI-D与孕中期胎盘位置偏低相关,仍需更多研究评估其与妊娠结局的关系。
要点
- 孕中期三维超声测量胎盘脐带插入点距胎盘边缘距离(PCI-D)可用于评估胎盘形态。
- 低置胎盘或前置胎盘与较长的PCI-D相关(P=0.03)。
- PCI-D与出生体重z评分(P=0.09)及孕次(P=0.10)的关联未达统计学显著。
核心结论
- PCI-D与孕中期胎盘位置偏低相关,可能还与出生体重和多次妊娠等因素有关,但后两者未达统计学显著;仍需更多研究评估妊娠相关因素对PCI-D的影响及PCI-D对妊娠结局的影响。
研究设计与样本
- 回顾性队列研究,纳入216例单胎初产妇,孕14至23周行产科超声且宫颈长度大于3.0 cm,于孕24至42周分娩;采用三维胎盘容积并使用Virtual Organ计算机辅助分析软件(GE Healthcare,Milwaukee,WI)获取PCI-D;拟合广义线性回归和广义相加模型分析PCI-D与人口学和临床特征的关联。
诊断标准与关键数值
- PCI-D与低置胎盘或前置胎盘相关(P=0.03),低置胎盘或前置胎盘者PCI-D更长。
- PCI-D与出生体重z评分(P=0.09)和孕次(P=0.10)的关联未达统计学显著。
- PCI-D与产妇年龄、分娩孕周、分娩方式或5分钟Apgar评分无相关性。
临床应用与阅片要点
- 在孕中期胎儿结构筛查时,可利用三维超声测量胎盘脐带插入点距胎盘边缘的距离(PCI-D)。
- 测量PCI-D时需注意胎盘位置,低置胎盘或前置胎盘者PCI-D可能更长。
局限性
- 原文结论指出仍需更多研究评估妊娠相关因素对PCI-D的影响及PCI-D对妊娠结局的影响。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: The influence of placental morphologic characteristics on pregnancy outcomes is poorly understood. Our objective was to evaluate the relationship of the distance of the placental cord insertion from the placental edge (PCI-D) with associated placental characteristics as well as birth outcomes.
METHODS: We performed a retrospective cohort study of nulliparous women with singleton gestations undergoing obstetric ultrasound examinations between 14 and 23 weeks' gestation with a cervical length of greater than 3.0 cm who delivered between 24 and 42 weeks. A 3-dimensional volume of the placenta was evaluated. The PCI-D was obtained with Virtual Organ computer-aided analysis software (GE Healthcare, Milwaukee, WI). Generalized linear regression and generalized additive models were fitted to explore the associations between the PCI-D in relation to demographic and clinical characteristics.
RESULTS: A total of 216 pregnancies were included in the analysis. The PCI-D did not correlate with maternal age, gestational age at delivery, mode of delivery, or 5-minute Apgar score. Although not statistically significant, the birth weight z score (P = .09) was associated with a longer PCI-D, and gravidity was associated with a shorter PCI-D (P = .10). A low-lying placenta or placenta previa was associated with a longer PCI-D (P = .03).
CONCLUSIONS: The PCI-D is associated with a low placental position in the second trimester. These data are helpful for understanding placental development. The PCI-D may be associated with pregnancy-related factors such as birth weight and multigravidity. More research is required to evaluate the effects of pregnancy-related factors on the PCI-D and the effect of the PCI-D on pregnancy outcomes.
引用
- Rouse C, Cantonwine DE, Shipp TD, et al. Assessment of the Placental Cord Insertion Using 3-Dimensional Ultrasound at the Time of the Structural Fetal Survey. J Ultrasound Med. 2018. PMID: 30480334. doi:10.1002/jum.14868
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。