文献速递妇产影像US

四维经会阴超声容积渲染模式检测隐匿性子宫脱垂:一项回顾性观察研究

Detection of Concealed Uterine Prolapse in the Volume-Rendering Mode of 4-Dimensional Translabial Ultrasound: A Retrospective Observational Study.
PubMed 文献 · J Ultrasound Med · 2018-11-04

本研究回顾性分析233例接受国际尿控协会盆腔器官脱垂量化系统检查及经会阴超声检查的女性,在容积渲染轴平面上测量阴道管前后径。子宫脱垂者阴道管呈眼形,平均前后径17.8 mm;正常子宫下降者平均5.6 mm,第95百分位为10 mm。前后径大于10 mm预测临床子宫脱垂的比值比为82.3,该征象可能有助于检测复杂盆腔器官脱垂中的隐匿性子宫脱垂。

要点

  • 容积渲染轴平面上阴道管呈眼形且前后径大于10 mm提示子宫脱垂。
  • 子宫脱垂者阴道管平均前后径17.8 mm,正常子宫下降者为5.6 mm。
  • 超声与体格检查对子宫脱垂的评估一致性良好(κ=0.76)。

核心结论

  • 容积渲染轴平面上阴道管呈眼形且前后径大于10 mm是子宫脱垂的征象,该征象可能有助于检测复杂盆腔器官脱垂中的隐匿性子宫脱垂。

研究设计与样本

  • 回顾性观察研究,纳入253例接受国际尿控协会盆腔器官脱垂量化系统检查及经会阴超声检查的女性,最终分析233例的有效数据。

关键影像表现/征象

  • 子宫脱垂者阴道管呈眼形,平均前后径17.8 mm(范围10.7-26.8 mm);正常子宫下降者平均前后径5.6 mm(范围2.3-10.5 mm,第95百分位10 mm)。

诊断标准与关键数值

  • 阴道管增宽定义为正常子宫下降女性中前后径超过第95百分位,即大于10 mm;45例隐匿性子宫下降中32例阴道管增宽(前后径大于10 mm),27例存在临床子宫脱垂;超声预测临床子宫脱垂的比值比为82.3;体格检查与超声所见一致性κ=0.76(P<.001)。

临床应用与阅片要点

  • 在容积渲染轴平面上测量阴道管前后径,眼形且前后径大于10 mm的征象可能有助于检测复杂盆腔器官脱垂中的隐匿性子宫脱垂。

局限性

  • 原文未报告局限性

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: To assess the association between a widened vaginal canal on volume-rendered ultrasound (US) imaging with concealed uterine prolapse.

METHODS: This work was a retrospective study of 253 women who had an International Continence Society Pelvic Organ Prolapse Quantification System examination and translabial US examination. The anteroposterior diameter of the vaginal canal was measured in the rendered axial plane for all women. The widened vaginal canal was defined as an anteroposterior diameter above the 95th centile in women with normal uterine descent. The performance of the widened vaginal canal for prediction of clinical uterine prolapse was tested.

RESULTS: Valid data from 233 women were analyzed. A mean anteroposterior diameter of 5.6 mm (range, 2.3-10.5 mm; 95th percentile, 10 mm) was seen in 119 women with normal uterine descent. An eye-shaped vaginal canal with a mean anteroposterior diameter of 17.8 mm (range, 10.7-26.8 mm) was seen in 69 women with uterine prolapse. A widened vaginal canal was defined as an anteroposterior diameter of greater than 10 mm. Of 45 concealed uterine descents, 32 had a widened vaginal canal (ie, anteroposterior diameter > 10 mm), and 27 had clinical uterine prolapse. The κ test showed good agreement between physical and US findings (κ = 0.76; P < .001). Ultrasound findings had excellent predictive value (odds ratio, 82.3) for the diagnosis of clinical uterine prolapse.

CONCLUSIONS: An eye-shaped vaginal canal with an anteroposterior diameter of greater than 10 mm in the rendered axial plane was a sign of uterine prolapse. This sign may be helpful for detecting concealed uterine prolapse in complex pelvic organ prolapse.

来源:J Ultrasound Med,查看原文。版权归原作者所有。

引用

  1. Wen L, Li Y, Qing Z, et al. Detection of Concealed Uterine Prolapse in the Volume-Rendering Mode of 4-Dimensional Translabial Ultrasound: A Retrospective Observational Study. J Ultrasound Med. 2018. PMID: 30393866. doi:10.1002/jum.14855

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。