文献速递泌尿生殖MR

功能磁共振成像诊断局部复发前列腺癌:所有脉冲序列都有帮助吗

Functional Magnetic Resonance Imaging in the Diagnosis of Locally Recurrent Prostate Cancer: Are All Pulse Sequences Helpful?
PubMed 文献 · Korean J Radiol · 2018-10-18

该Meta分析纳入13项研究共826例根治性前列腺切除术后患者、7项研究共329例放疗后患者及11项研究共1669个六分区活检,评估功能MRI诊断局部复发前列腺癌的准确性。根治性前列腺切除术后汇总敏感度与特异度均为91%,AUC为0.96;放疗后按患者分析汇总敏感度80%、特异度81%,AUC为0.88;按六分区活检分析汇总敏感度54%、特异度91%,AUC为0.85。放疗后扩散加权MRI或1H-MRS联合T2WI较单用T2WI可提高敏感度,但根治性前列腺切除术后功能MRI数据可能并未增强T2WI的检出能力。

要点

  • 根治性前列腺切除术后功能MRI汇总敏感度91%、特异度91%,AUC 0.96。
  • 放疗后按患者分析功能MRI汇总敏感度80%、特异度81%,AUC 0.88。
  • 放疗后按六分区活检分析汇总敏感度54%、特异度91%,AUC 0.85。

核心结论

  • 功能MRI数据可能并未增强T2WI对根治性前列腺切除术后患者局部复发前列腺癌的检出能力,而扩散加权MRI和1H-MRS数据可能提高放疗后患者T2WI的敏感度。

研究设计与样本

  • Meta分析,检索PubMed、Embase、Cochrane Central Register of Controlled Trials和Cochrane Database of Systematic Reviews自1995年1月1日至2016年12月31日的文献,采用分层逻辑回归建模(包括双变量建模和分层汇总受试者工作特征曲线)定量汇总诊断准确性。

诊断标准与关键数值

  • 根治性前列腺切除术后(13项研究、826例患者)功能MRI汇总敏感度91%、特异度91%,AUC 0.96。
  • 放疗后按患者分析(7项研究、329例患者)功能MRI汇总敏感度80%、特异度81%,AUC 0.88。
  • 放疗后按六分区活检分析(11项研究、1669个六分区活检)功能MRI汇总敏感度54%、特异度91%,AUC 0.85。
  • 放疗后按患者分析,扩散加权MRI联合T2WI较单用T2WI敏感度显著提高(p=0.027)。
  • 放疗后按六分区活检分析,扩散加权MRI联合T2WI较单用T2WI敏感度显著提高(p=0.046),1H-MRS联合T2WI亦较单用T2WI敏感度显著提高(p=0.036)。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: To perform a meta-analysis to quantitatively assess functional magnetic resonance imaging (MRI) in the diagnosis of locally recurrent prostate cancer.

MATERIALS AND METHODS: A comprehensive search of the PubMed, Embase, Cochrane Central Register of Controlled Trials, and Cochrane Database of Systematic Reviews was conducted from January 1, 1995 to December 31, 2016. Diagnostic accuracy was quantitatively pooled for all studies by using hierarchical logistic regression modeling, including bivariate modeling and hierarchical summary receiver operating characteristic (HSROC) curves (AUCs). The Z test was used to determine whether adding functional MRI to T2-weighted imaging (T2WI) results in significantly increased diagnostic sensitivity and specificity.

RESULTS: Meta-analysis of 13 studies involving 826 patients who underwent radical prostatectomy showed a pooled sensitivity and specificity of 91%, and the AUC was 0.96. Meta-analysis of 7 studies involving 329 patients who underwent radiotherapy showed a pooled sensitivity of 80% and specificity of 81%, and the AUC was 0.88. Meta-analysis of 11 studies reporting 1669 sextant biopsies from patients who underwent radiotherapy showed a pooled sensitivity of 54% and specificity of 91%, and the AUC was 0.85. Sensitivity after radiotherapy was significantly higher when diffusion-weighted MRI data were combined with T2WI than when only T2WI results were used. This was true when meta-analysis was performed on a per-patient basis (p = 0.027) or per sextant biopsy (p = 0.046). A similar result was found when 1H-magnetic resonance spectroscopy (1H-MRS) data were combined with T2WI and sextant biopsy was the unit of analysis (p = 0.036).

CONCLUSION: Functional MRI data may not strengthen the ability of T2WI to detect locally recurrent prostate cancer in patients who have undergone radical prostatectomy. By contrast, diffusion-weight MRI and 1H-MRS data may improve the sensitivity of T2WI for patients who have undergone radiotherapy.

来源:Korean J Radiol,查看原文。版权归原作者所有。

引用

  1. Liao XL, Wei JB, Li YQ, et al. Functional Magnetic Resonance Imaging in the Diagnosis of Locally Recurrent Prostate Cancer: Are All Pulse Sequences Helpful? Korean J Radiol. 2018. PMID: 30386142. doi:10.3348/kjr.2018.19.6.1110

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。