文献速递技术与安全

对比剂注射前肾功能评估:基于不准确估计的正确决策

Assessment of renal function before contrast media injection: right decisions based on inaccurate estimates.
PubMed 文献 · Eur Radiol · 2018-11-09

该研究在50例患者中比较了Cockcroft-Gault方程估计的肾小球滤过率与51Cr-EDTA测定的参考肾小球滤过率及肌酐清除率,发现估计值个体预测误差大但分类诊断准确度好,认为预测方程结果应仅作为二分类变量使用,数值需求时应采用更准确的核素或实验室方法测定。

要点

  • 预测方程估计的肾小球滤过率个体数值不准确,但将患者肾小球滤过率分类为低于或高于特定水平时诊断准确度很好。
  • Cockcroft-Gault方程以二分类变量分类肾小球滤过率低于30和60 ml/min/1.73 m2时诊断准确度分别为80%和94%。
  • 作者认为预测方程结果应仅作为二分类变量使用和报告。

核心结论

  • 尽管个体肾小球滤过率估计值方差大且预测准确度差,但大多数估计值能正确将患者肾小球滤过率分类为低于特定水平;预测方程结果应仅作为二分类变量使用和报告,如需肾小球滤过率数值应采用更准确的核素或实验室方法测定。

研究设计与样本

  • 在50例患者中,以51铬标记乙二胺四乙酸血浆清除率测定的肾小球滤过率为参考,与肌酐清除率及Cockcroft-Gault预测方程估计的肾小球滤过率进行比较,并将肌酐清除率和Cockcroft-Gault方程结果分别作为连续变量、分类变量和二分类变量分析。

诊断标准与关键数值

  • Cockcroft-Gault方程作为分类变量时,将患者慢性肾脏病分期分类的诊断准确度:慢性肾脏病3期为74%,慢性肾脏病4期为62%。
  • Cockcroft-Gault方程作为二分类变量时,将患者肾小球滤过率分类为低于30和60 ml/min/1.73 m2的诊断准确度分别为80%和94%。
  • Cockcroft-Gault方程作为连续变量时,个体肾小球滤过率估计值的预测误差大,超过肌酐清除率的预测误差。
  • 其他预测方程的性能与Cockcroft-Gault方程无显著差异。

临床应用与阅片要点

  • 放射学指南要求在特定对比剂检查前估计肾小球滤过率以评估肾功能。
  • 作者认为预测方程结果应仅作为二分类变量使用和报告。
  • 作者认为如需肾小球滤过率数值,应采用更准确的核素或实验室方法测定。

局限性

  • 原文未报告局限性

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: Information on renal function required before specified radiological examinations with contrast agents is usually obtained through prediction equations using serum creatinine and anthropometric data. The aim of our study was to demonstrate discrepancy between poor prediction and good diagnostic accuracy of glomerular filtration rate (GFR) estimated by prediction equations.

METHODS: In 50 patients, reference GFR was measured as plasma clearance of 51-chromium labeled ethylene-diamine-tetraacetic-acid (51Cr-EDTA) and compared with GFR assayed by creatinine clearance (CC) and estimated by Cockcroft-Gault prediction equation (CG). For comparisons, CC and CG were considered as continuous, categorical, and binary variables. Accuracy of the reference GFR prediction was expressed in terms of prediction errors and diagnostic accuracy indices.

RESULTS: As continuous variable, CG estimated individual values of GFR with large prediction error exceeding that of CC. As categorical variable, it classified the patient stage of chronic kidney disease (CKD) with medium diagnostic accuracy of 74% (CKD 3) and 62% (CKD 4). As binary variable, CG classified individual patient's GFR below 30 and 60 ml/min/1.73 m2 with good diagnostic accuracy of 80 and 94%, respectively. Performance of other prediction equations did not significantly differ from CG.

CONCLUSIONS: Despite large variance and poor prediction accuracy of individual GFR estimates, most of them correctly classified individual patient's GFR below specified level. Results of prediction equations thus should be used and reported exclusively as binary variables, while numerical values of GFR, if required, should be measured by more accurate radionuclide or laboratory methods.

KEY POINTS: • Radiological guidelines on contrast media require estimation of glomerular filtration rate to assess kidney function before specified contrast examinations. • Estimated glomerular filtration rate is obtained through prediction equations using serum creatinine and anthropometric data as predictors. • While numerical estimates of glomerular filtration rate are inaccurate (their prediction accuracy is poor), diagnostic accuracy of binary estimates (ability to classify patient's glomerular filtration rate below or above a specified level) is very good.

来源:Eur Radiol,查看原文。版权归原作者所有。

引用

  1. Ptáčník V, Zogala D, Skibová D, et al. Assessment of renal function before contrast media injection: right decisions based on inaccurate estimates. Eur Radiol. 2018. PMID: 30413953. doi:10.1007/s00330-018-5753-z

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。