多普勒超声设备(包括弹性成像)可准确诊断严重肝纤维化

Doppler ultrasonography devices, including elastography, allow for accurate diagnosis of severe liver fibrosis.
PubMed 文献 · Eur J Radiol · 2018-09-19

研究纳入514例慢性肝病患者,在同一天进行多普勒超声检查和肝活检,评估在简单多普勒超声征象阳性后使用弹性成像能否提高严重肝纤维化(Metavir F≥3)的检出。结果显示,至少一项简单征象阳性诊断严重纤维化的敏感度为85.6%、特异度为36.1%;加做VTQ(≥1.59 m/s)后特异度升至80.8%、敏感度降至73.7%,SSI(≥9.5 kPa)结果为特异度73.3%、敏感度81.5%。结论认为弹性成像提高了多普勒超声检出严重纤维化的准确性。

要点

  • 简单多普勒超声征象(肝表面不规则、脾大≥110 mm、肝静脉解调)任一阳性对严重纤维化敏感度85.6%、特异度36.1%。
  • 多普勒征象阳性者加做VTQ(≥1.59 m/s)后特异度升至80.8%、敏感度降至73.7%。
  • 加做SSI(≥9.5 kPa)后特异度73.3%、敏感度81.5%。

核心结论

  • 弹性成像提高了多普勒超声检出严重肝纤维化的准确性;这一两步流程有助于放射科医生在常规多普勒超声检查中准确识别需要转诊至肝病专科医生的患者。

研究设计与样本

  • 单中心研究,连续纳入514例接受经皮肝活检的慢性肝病患者,所有患者在同一天进行多普勒超声检查和Virtual Touch Quantification(VTQ)肝硬度测量,其中326例还进行了2D剪切波弹性成像(SSI)肝硬度测量,以肝活检Metavir F≥3作为严重纤维化的参考标准。

关键影像表现/征象

  • 三个简单多普勒超声征象为肝表面不规则、脾大≥110 mm和肝静脉解调,多因素分析证实其与严重纤维化独立相关。
  • 至少一项简单多普勒超声征象阳性对严重肝纤维化的敏感度为85.6%、特异度为36.1%。

诊断标准与关键数值

  • 至少一项简单多普勒超声征象阳性诊断严重肝纤维化(Metavir F≥3):敏感度85.6%、特异度36.1%。
  • 多普勒超声征象阳性者加做VTQ(阈值≥1.59 m/s):特异度80.8%、敏感度73.7%。
  • 多普勒超声征象阳性者加做SSI(阈值≥9.5 kPa):特异度73.3%、敏感度81.5%。

临床应用与阅片要点

  • 在常规多普勒超声检查中,可先观察肝表面不规则、脾大≥110 mm和肝静脉解调这三个简单征象。
  • 简单征象任一阳性时,加做VTQ(≥1.59 m/s)或SSI(≥9.5 kPa)可提高诊断严重肝纤维化的特异度,但敏感度有所下降。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: Advanced chronic liver disease is frequent yet largely underdiagnosed. Doppler-US is a common examination and we recently identified three simple Doppler-US signs associated with severe liver fibrosis. Recent Doppler-US devices include elastography modules, allowing for liver stiffness measurement (LSM). Our aim was to assess whether the use of elastography following positive simple Doppler-US signs improves the detection of severe liver fibrosis in a single Doppler-US examination.

METHODS: 514 patients with chronic liver disease who consecutively underwent percutaneous liver biopsy were included in the study. All patients had a Doppler-US examination and LSM with Virtual Touch Quantification (VTQ) on the same day as a liver biopsy. A subset of 326 patients also had LSM with 2D shear wave elastography (SSI). Severe fibrosis was defined as Metavir F ≥ 3 on liver biopsy.

RESULTS: Multivariate analysis confirmed our three simple Doppler-US signs (liver surface irregularity, splenomegaly ≥110 mm, and demodulation of hepatic veins) as independently associated with severe fibrosis. The presence of at least one of these three signs showed 85.6% sensitivity and 36.1% specificity for the diagnosis of severe liver fibrosis. Using VTQ (≥1.59 m/s) where there was a positive Doppler-US sign increased the specificity to 80.8%, at the cost of a decrease in sensitivity (73.7%). Similar results were obtained with SSI (≥9.5 kPa), with 73.3% specificity and 81.5% sensitivity.

CONCLUSION: Elastography improves the accuracy of Doppler-US in the detection of severe fibrosis. This two-step procedure will help radiologists to accurately identify patients who need to be referred to specialist hepatologists during routine Doppler-US examinations.

来源:Eur J Radiol,查看原文。版权归原作者所有。

引用

  1. Delahaye J, Bazeries P, Lannes A, et al. Doppler ultrasonography devices, including elastography, allow for accurate diagnosis of severe liver fibrosis. Eur J Radiol. 2018. PMID: 30396646. doi:10.1016/j.ejrad.2018.09.019

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。