磁共振弹性成像鉴别自身免疫性胰腺炎与胰腺导管腺癌的初步研究
这项前瞻性研究纳入14例自身免疫性胰腺炎、26例胰腺导管腺癌和14名健康志愿者,采用40 Hz、3 T磁共振弹性成像测量胰腺硬度。自身免疫性胰腺炎硬度显著高于健康胰腺、显著低于胰腺导管腺癌,基于硬度及高硬度区分布与形态构建的Rad评分鉴别两种病变的AUC为0.948,敏感度92.9%、特异度84.6%。7例自身免疫性胰腺炎患者激素治疗后硬度显著下降。
要点
- 自身免疫性胰腺炎胰腺硬度为2.67 kPa,高于健康胰腺1.24 kPa,低于胰腺导管腺癌3.78 kPa。
- 弥漫性及多发病灶更常见于自身免疫性胰腺炎,孤立性及结节样病灶更常见于胰腺导管腺癌。
- Rad评分鉴别自身免疫性胰腺炎与胰腺导管腺癌AUC为0.948,优于单个影像参数。
核心结论
- 磁共振弹性成像有望作为一种定量影像方法用于鉴别自身免疫性胰腺炎与胰腺导管腺癌,并监测自身免疫性胰腺炎的治疗反应。
研究设计与样本
- 前瞻性研究,纳入14例自身免疫性胰腺炎、26例胰腺导管腺癌患者和14名健康志愿者,均于入组时行胰腺磁共振弹性成像(40 Hz,3 T扫描仪)。
关键影像表现/征象
- 自身免疫性胰腺炎胰腺硬度为2.67 kPa(四分位距2.24-3.56 kPa),健康胰腺为1.24 kPa(1.18-1.24 kPa),胰腺导管腺癌为3.78 kPa(3.22-5.11 kPa)。
- 弥漫性病灶在自身免疫性胰腺炎为4例、胰腺导管腺癌为1例(P=0.043)。
- 多发病灶在自身免疫性胰腺炎为3例、胰腺导管腺癌为0例(P=0.037)。
- 孤立性病灶在胰腺导管腺癌为25例、自身免疫性胰腺炎为7例(P=0.001)。
- 结节样病灶在胰腺导管腺癌为18例、自身免疫性胰腺炎为2例(P=0.002)。
诊断标准与关键数值
- Rad评分鉴别自身免疫性胰腺炎与胰腺导管腺癌的AUC为0.948,敏感度92.9%,特异度84.6%。
- 单个影像参数鉴别自身免疫性胰腺炎与胰腺导管腺癌的AUC为0.607至0.782,均低于Rad评分(均P<0.05)。
- 7例自身免疫性胰腺炎患者激素治疗开始后复查磁共振弹性成像,胰腺硬度从2.66 kPa(2.29至3.05 kPa)降至1.55 kPa(1.43至1.67 kPa),P=0.016。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: To assess the value of magnetic resonance elastography (MRE) in patients with autoimmune pancreatitis (AIP) and in the differentiation of AIP from pancreatic ductal adenocarcinoma (PDAC).
METHOD AND MATERIALS: This prospective study included 14 AIP patients, 26 PDAC patients, and 14 healthy volunteers. All participants underwent pancreatic MRE (40-Hz; 3 T scanner) at enrollment, and 7 AIP patients underwent a second MRE after initiation of steroid therapy. Pancreatic stiffness values were obtained by MRE and a new logistic regression model (the calculated Rad score) was used to combine pancreatic stiffness and the distribution and shape of high-stiffness areas for differentiation of AIP and PDAC. The area under the curve (AUC) was calculated for all parameters using receiver operating characteristic (ROC) analysis.
RESULTS: Pancreatic stiffness was significantly higher (2.67 kPa [interquartile range, 2.24-3.56 kPa]) in AIP than in healthy pancreas (1.24 kPa [1.18-1.24 kPa]) and significantly lower in AIP than in PDAC (3.78 kPa [3.22-5.11 kPa]; both P < 0.05). Diffuse (n = 4 vs 1; P = 0.043) and multiple (n = 3 vs 0; P = 0.037) lesions were more common in AIP, while solitary (n = 25 vs 7; P = 0.001) and nodular lesions (n = 18 vs 2; P = 0.002) were more frequent in PDAC. Rad scores outperformed individual imaging parameters in distinguishing AIP from PDAC (AUC, 0.948 vs 0.607 to 0.782; all P < 0.05), with 84.6% specificity and 92.9% sensitivity. Pancreatic stiffness in AIP decreased significantly, from 2.66 kPa [2.29 to 3.05 kPa] to 1.55 kPa [1.43 to 1.67 kPa] (P = 0.016), during treatment.
CONCLUSIONS: MRE shows promise as a quantitative imaging method for differentiating AIP from PDAC and for monitoring the treatment response in AIP.
引用
- Shi Y, Cang L, Zhang X, et al. The use of magnetic resonance elastography in differentiating autoimmune pancreatitis from pancreatic ductal adenocarcinoma: A preliminary study. Eur J Radiol. 2018. PMID: 30396645. doi:10.1016/j.ejrad.2018.09.001
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。