文献速递腹部外周血管介入CTUS

CT血管成像虚拟肝静脉压力梯度(CHESS 1601):无创诊断门静脉高压的前瞻性多中心研究

Virtual Hepatic Venous Pressure Gradient with CT Angiography (CHESS 1601): A Prospective Multicenter Study for the Noninvasive Diagnosis of Portal Hypertension.
PubMed 文献 · Radiology · 2018-11-20

前瞻性多中心诊断试验纳入102例肝硬化患者,基于CT血管成像三维重建与计算流体动力学构建虚拟肝静脉压力梯度模型。训练队列(n=29)预测临床显著门静脉高压的AUC为0.83(95%CI:0.58,1.00),验证队列(n=73)AUC为0.89(95%CI:0.81,0.96);虚拟HVPG与有创HVPG相关(R=0.61,P<.001),可满足排除(7.3 mm Hg)与诊断(13.0 mm Hg)临床显著门静脉高压的性能。

要点

  • 虚拟HVPG基于CT血管成像三维重建与计算流体动力学构建,与有创HVPG相关(R=0.61,P<.001)。
  • 验证队列预测临床显著门静脉高压AUC为0.89(95%CI:0.81,0.96),训练队列为0.83(95%CI:0.58,1.00)。
  • 观察者间与观察者内一致性分别为0.88和0.96,提示虚拟HVPG测量重复性良好。

核心结论

  • 虚拟肝静脉压力梯度计算模型的准确性与有创HVPG显著相关,并在肝硬化临床显著门静脉高压的无创诊断中表现出良好性能。

研究设计与样本

  • 前瞻性多中心诊断试验(ClinicalTrials.gov标识NCT02842697),2016年8月至2017年4月从三家高容量肝病中心连续纳入102例符合条件的各种病因肝硬化参与者,均接受经颈静脉HVPG测量、多普勒超声和CT血管成像,虚拟HVPG基于三维重建模型与计算流体动力学开发。

诊断标准与关键数值

  • 训练队列(n=29)虚拟HVPG预测临床显著门静脉高压的AUC为0.83(95%CI:0.58,1.00);验证队列(n=73)AUC为0.89(95%CI:0.81,0.96);虚拟HVPG与有创HVPG相关(R=0.61,P<.001),排除与诊断临床显著门静脉高压的界值分别为7.3 mm Hg和13.0 mm Hg;观察者间与观察者内一致性分别为0.88和0.96。

临床应用与阅片要点

  • 虚拟HVPG与有创HVPG相关(R=0.61,P<.001),在验证队列中预测临床显著门静脉高压的AUC为0.89(95%CI:0.81,0.96),并可通过7.3 mm Hg与13.0 mm Hg界值分别满足排除与诊断临床显著门静脉高压的性能。

局限性

  • 原文未报告局限性

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

Purpose To develop and validate a computational model for estimating hepatic venous pressure gradient (HVPG) based on CT angiographic images, termed virtual HVPG, to enable the noninvasive diagnosis of portal hypertension in patients with cirrhosis. Materials and Methods In this prospective multicenter diagnostic trial (ClinicalTrials.gov identifier: NCT02842697), 102 consecutive eligible participants (mean age, 47 years [range, 21-75 years]; 68 men with a mean age of 44 years [range, 21-73 years] and 34 women with a mean age of 52 years [range, 24-75 years]) were recruited from three high-volume liver centers between August 2016 and April 2017. All participants with cirrhosis of various causes underwent transjugular HVPG measurement, Doppler US, and CT angiography. Virtual HVPG was developed with a three-dimensional reconstructed model and computational fluid dynamics. Results In the training cohort (n = 29), the area under the receiver operating characteristic curve (AUC) of virtual HVPG in the prediction of clinically significant portal hypertension (CSPH) was 0.83 (95% confidence interval [CI]: 0.58, 1.00). The diagnostic performance was prospectively confirmed in the validation cohort (n = 73), with an AUC of 0.89 (95% CI: 0.81, 0.96). Inter- and intraobserver agreement was 0.88 and 0.96, respectively, suggesting the good reproducibility of virtual HVPG measurements. There was good correlation between virtual HVPG and invasive HVPG (R = 0.61, P < .001), with a satisfactory performance to rule out (7.3 mm Hg) and rule in (13.0 mm Hg) CSPH. Conclusion The accuracy of a computational model of virtual hepatic venous pressure gradient (HVPG) shows significant correlation with invasive HVPG. The virtual HVPG also showed a good performance in the noninvasive diagnosis of clinically significant portal hypertension in cirrhosis. © RSNA, 2018 Online supplemental material is available for this article. See also the editorial by Malayeri in this issue.

来源:Radiology,查看原文。版权归原作者所有。

引用

  1. Qi X, An W, Liu F, et al. Virtual Hepatic Venous Pressure Gradient with CT Angiography (CHESS 1601): A Prospective Multicenter Study for the Noninvasive Diagnosis of Portal Hypertension. Radiology. 2018. PMID: 30457484. doi:10.1148/radiol.2018180425

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。