文献速递腹部CT

单源双能CT定量区分混合成分胰管结石中碳酸钙与非碳酸钙成分的离体研究

Quantification and differentiation of composition of mixed pancreatic duct stones using single-source dual-energy CT: an ex vivo study.
PubMed 文献 · Abdom Radiol (NY) · 2019-01-01

本离体研究以显微CT为参考标准,用单源双能CT(80/140 kVp)扫描12枚混合成分胰管结石,计算CT值比值(CTR)并预设阈值分类碳酸钙(CA)与非碳酸钙(NCA)成分。最佳CTR阈值为1.16,均方根误差6.0%,双能CT与显微CT的组成定量无显著差异(p=0.414)。

要点

  • 最佳CTR阈值为1.16,用于区分混合性胰管结石的CA与NCA成分
  • 该阈值下均方根误差为6.0%,最小与最大绝对误差分别为0.22%和11.35%
  • 双能CT与显微CT的CA/NCA组成定量无显著差异(p=0.414)

核心结论

  • 单源双能CT是定量区分混合成分胰管结石中CA与NCA成分的潜在方法。

研究设计与样本

  • 离体研究,分析12枚取自本院普外科的胰管结石,以显微CT为CA与NCA成分参考标准,置于直径35 cm的TOS水体模模拟标准成人体型,采用80 kVp/140 kVp单源双能CT扫描。

诊断标准与关键数值

  • CTR定义为80 kVp与140 kVp下CT值之比,预设阈值范围1.00–1.25;CTR高于阈值的像素归为CA,低于阈值的归为NCA;最佳CTR阈值为1.16,均方根误差6.0%,最小与最大绝对误差分别为0.22%和11.35%。

临床应用与阅片要点

  • 作者认为单源双能CT是定量区分混合成分胰管结石CA与NCA成分的潜在方法。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: To evaluate the feasibility of using single-source dual-energy CT (SS DECT) to quantify and differentiate calcium carbonate (CA) and non-calcium carbonate (NCA) components of pancreatic duct stones (PDS) with mixed composition.

MATERIALS AND METHODS: A total of 12 PDS harvested from general surgery department in our hospital were analyzed with micro-CT as a reference standard for CA and NCA composition. These stones were placed in a TOS water phantom of 35 cm diameter to simulate standard adult body size. High- and low-energy image sets were acquired from SS DECT scans with high/low tube potential pairs of 80 kVp/140 kVp. All the image sets were imported into an in-house software for further post-processing. CT number ratio (CTR), defined as the ratio of the CT number at 80 kVp to 140 kVp was calculated for each pixel of the images. Threshold was preset between 1.00 and 1.25 to classify CA and NCA components. Pixels in PDS with CTR higher than the threshold were classified as CA, and those with CTR lower than the threshold were classified as NCA. The percentages of CA and NCA for each stone were determined by calculating the number of CA and NCA pixels. Finally, the minimal, maximal and root-mean-square errors (RMSE) of composition measured by SS DECT under each threshold were calculated by referring to the composition data from micro-CT. The optimal threshold was determined with the minimal RMSE. A paired t test was used to compare the stone composition determined by DECT with micro-CT.

RESULTS: The optimal CTR threshold was 1.16, with RMSE of 6.0%. The minimum and maximum absolute errors were 0.22% and 11.35%, respectively. Paired t test showed no significant difference between DECT and micro-CT for characterizing CA and NCA composition (p = 0.414).

CONCLUSION: SS DECT is a potential approach for quantifying and differentiating CA and NCA components in PDS with mixed composition.

来源:Abdom Radiol (NY),查看原文。版权归原作者所有。

引用

  1. Liu R, Su W, Chen X, et al. Quantification and differentiation of composition of mixed pancreatic duct stones using single-source dual-energy CT: an ex vivo study. Abdom Radiol (NY). 2019. PMID: 30474724. doi:10.1007/s00261-018-1837-0

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。