文献速递腹部技术与安全US

基于常规超声图像肝组织纹理异质性卡方分析的纤维化面积分数定量肝纤维化程度

Quantification of Degree of Liver Fibrosis Using Fibrosis Area Fraction Based on Statistical Chi-Square Analysis of Heterogeneity of Liver Tissue Texture on Routine Ultrasound Images.
PubMed 文献 · Acad Radiol · 2018-11-02

回顾性分析100例接受非靶向超声引导活检患者的常规超声图像,训练组31例确定卡方阈值6.0,验证组区分Ishak F0-3与F4-6(P<0.0001),纤维化面积分数与病理分级强相关(AUC=0.89)。

要点

  • 常规超声图像纹理卡方分析可定量纤维化面积分数,辅助区分F0-3与F4-6。
  • 训练组最佳阈值6.0时AUC=0.985,敏感度93.7%,特异度93.3%。
  • 验证组F0-3平均纤维化面积分数4.7%,F4-6为17.3%。

核心结论

  • 该方法有望成为常规超声图像上区分正常或低级别肝纤维化(F0-3)与晚期肝纤维化或肝硬化(F4-6)的无创工具,支持进一步开发纹理异质性分析作为定量生物标志物。

研究设计与样本

  • 回顾性患者研究,经机构审查委员会批准,纳入100例(男61例,女39例,18-81岁)接受非靶向超声引导活检患者的超声图像,随机分为训练组31例和验证组其余病例,以活检病理Ishak纤维化评分为参考标准。

关键影像表现/征象

  • 在肝组织内手动选取约4-6 cm²的原发感兴趣区,避开非肝实质,内含大量25×25像素的次级感兴趣区。
  • 计算次级感兴趣区图像梯度样本方差σ²,由次级感兴趣区平均梯度µ理论推导原发感兴趣区总体方差,计算χ²=σ²/总体方差形成肝组织异质性χ²图。
  • 训练组优化阈值6.0将χ²图转为二值图像,计算纤维化面积分数(纤维化面积占原发感兴趣区总面积的比例)。

诊断标准与关键数值

  • 训练组最佳设置总体方差=6.0时,区分F0-3与F4-6的P<0.0001,AUC=0.985,敏感度93.7%,特异度93.3%。
  • 验证组应用该设置后两类间P<0.0001,F0-3类平均纤维化面积分数4.7%(范围1.7%-11.4%),F4-6类平均17.3%(范围9.8%-29.6%)。
  • 纤维化面积分数与活检组织学纤维化分级强相关,AUC=0.89,敏感度87.9%,特异度90.3%。

临床应用与阅片要点

  • 在常规超声图像上选取肝实质原发感兴趣区(约4-6 cm²)并避开非肝实质,是计算纤维化面积分数的前提。
  • 该方法基于图像梯度纹理异质性卡方分析,纤维化面积分数越高提示纤维化程度越重,可辅助区分F0-3与F4-6。
  • 原文结论认为该方法是颇有前景的无创工具,并支持进一步开发纹理异质性分析作为区分不同肝纤维化分级的定量生物标志物。

局限性

  • 原文为回顾性患者研究。
  • 原文结论称这些发现支持进一步开发纹理异质性分析,原文未报告其他局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

RATIONALE AND OBJECTIVES: We present a novel method to quantify the degree of liver fibrosis using fibrosis area fraction based on statistical chi-square analysis of heterogeneity of echo texture within liver on routine ultrasound images. We demonstrate, in a clinical study, that fibrosis area fraction derived this way has the potential to become a noninvasive, quantitative radiometric discriminator of normal or low-grade liver fibrosis (Ishak fibrosis score range = F0-3) and advanced liver fibrosis or cirrhosis (Ishak fibrosis score range = F4-6) on routine ultrasound images.

MATERIALS AND METHODS: This retrospective patient study was institutional review board approved. Ultrasound images of 100 patients (61 males, 39 females; 18-81 years) who underwent nontargeted ultrasound-guided biopsy were randomly divided into two groups: a training group consisted of 31 cases, and a validation group that contained the rest cases. An investigator manually selected a primary region of interest (ROI; approximately 4-6 cm2) in the liver tissue while avoiding nonhepatic parenchyma. The primary ROI contained a large number of secondary ROIs (25 × 25 pixels) to maintain the precision of statistical analysis. Sample variance σ2 of image gradient (a texture feature related to the amount of edge structures) was calculated in secondary ROIs in a roster scan fashion. A theoretical derivation was presented to estimate population variance [Formula: see text] of image gradient across the primary ROI from mean gradient µ of secondary ROIs. The χ2 (χ2 = σ2/ [Formula: see text] ) was computed at each secondary ROI, forming a χ2 map of liver tissue heterogeneity. A cut-off value was optimized from datasets in the training group by comparing to the fibrosis grades determined by biopsy. This cut-off value was then applied to the datasets in the validation group to convert the χ2 maps into binary images, from which fibrosis area fractions (fraction of fibrosis area to the total area of the primary ROI) were calculated and entered in a statistical analysis.

RESULTS: In the training group, the optimal setting was found to be [Formula: see text] = 6.0, which resulted a maximum discrimination of F0-3 vs F4-6: p < 0.0001, area under curve = 0.985, sensitivity = 93.7%, specificity = 93.3%. When this setting was applied to the datasets in the validation group, a distinct separation was seen between the two classes (p < 0.0001). F0-3 class had an average fibrosis area fraction of 4.7% (1.7%-11.4%), whereas the F4-6 class had an average fibrosis area fraction of 17.3% (9.8%-29.6%). A strong correlation was demonstrated between the fibrosis area fraction and histological fibrosis grade determined by biopsy (area under curve = 0.89, sensitivity = 87.9%, specificity = 90.3%).

CONCLUSION: The presented method is a promising noninvasive tool for distinguishing normal or low-grade liver fibrosis (F0-3) and advanced liver fibrosis or cirrhosis (F4-6) from routine ultrasound images. These findings support the further development of texture heterogeneity analysis, particularly fibrosis area fraction, as a quantitative biomarker for distinguishing various liver fibrosis grades.

来源:Acad Radiol,查看原文。版权归原作者所有。

引用

  1. Li J, Qureshi M, Gupta A, et al. Quantification of Degree of Liver Fibrosis Using Fibrosis Area Fraction Based on Statistical Chi-Square Analysis of Heterogeneity of Liver Tissue Texture on Routine Ultrasound Images. Acad Radiol. 2018. PMID: 30393055. doi:10.1016/j.acra.2018.10.004

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。