文献速递腹部CT

标准辐射剂量CT在检测结直肠癌肝转移方面优于降低辐射剂量CT

Detection of Colorectal Hepatic Metastases Is Superior at Standard Radiation Dose CT versus Reduced Dose CT.
PubMed 文献 · Radiology · 2018-11-27

前瞻性研究纳入52例活检证实的结直肠癌并疑似肝转移患者,在同一屏气下完成标准剂量(SD)与降低剂量(RD)腹部增强CT门静脉期扫描。RD较SD平均剂量降低54%,但病灶检出率降低(RD 212/260,82%;SD 252/260,97%;P<.001),每病灶敏感度RD 79% vs SD 94%(P<.001)。作者结论为中等程度降低辐射剂量即可损害CT对结直肠癌肝转移的评估,迭代重建未能维持观察者效能。

要点

  • RD CT较SD CT平均剂量降低54%,但病灶检出率RD 82%(212/260)低于SD 97%(252/260),P<.001。
  • 每病灶敏感度RD 79% vs SD 94%(P<.001),RD CT对2–15 mm肝转移灶检出受损。
  • 图像质量主观评分SD高于RD序列,ASIR-V评分高于ASIR和Veo 3.0。

核心结论

  • 中等程度降低辐射剂量即可损害CT对结直肠癌肝转移的评估,迭代重建的使用未能维持观察者效能。

研究设计与样本

  • 前瞻性研究,2017年5月至2017年11月纳入52例活检证实的结直肠癌并基线CT疑似肝转移成人,均行SD与RD门静脉期CT(同一屏气),3名放射科医师盲法在SD FBP与RD ASIR-V 60%序列上检出和定性2–15 mm病灶;参考标准由2名非盲共识复核者基于PACS病灶标记、多次对比检查和临床数据确定。

关键影像表现/征象

  • RD CT较SD CT平均剂量降低54%。
  • SD图像主观质量评分高于RD序列图像。
  • 迭代重建算法主观评分排序为ASIR-V高于ASIR和Veo 3.0。

诊断标准与关键数值

  • 共260个病灶(233个转移性,27个良性),RD CT检出212个(82%;95%CI 76%,86%),SD CT检出252个(97%;95%CI 94%,99%),P<.001。
  • 每病灶敏感度RD CT 79%(95%CI 74%,84%)vs SD CT 94%(95%CI 90%,96%),P<.001。

临床应用与阅片要点

  • 原文结论指出中等程度降低辐射剂量即可损害CT对结直肠癌肝转移的评估,迭代重建未能维持观察者效能。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

Purpose To evaluate colorectal cancer hepatic metastasis detection and characterization between reduced radiation dose (RD) and standard dose (SD) contrast material-enhanced CT of the abdomen and to qualitatively compare between filtered back projection (FBP) and iterative reconstruction algorithms. Materials and Methods In this prospective study (from May 2017 through November 2017), 52 adults with biopsy-proven colorectal cancer and suspected hepatic metastases at baseline CT underwent two portal venous phase CT scans: SD and RD in the same breath hold. Three radiologists, blinded to examination details, performed detection and characterization of 2-15-mm lesions on the SD FBP and RD adaptive statistical iterative reconstruction (ASIR)-V 60% series images. Readers assessed overall image quality and lesions between SD FBP and seven different iterative reconstructions. Two nonblinded consensus reviewers established the reference standard using the picture archiving and communication system lesion marks of each reader, multiple comparison examinations, and clinical data. Results RD CT resulted in a mean dose reduction of 54% compared with SD. Of the 260 lesions (233 metastatic, 27 benign), 212 (82%; 95% confidence interval [CI]: 76%, 86%) were detected with RD CT, whereas 252 (97%; 95% CI: 94%, 99%) were detected with SD (P < .001); per-lesion sensitivity was 79% (95% CI: 74%, 84%) and 94% (95% CI: 90%, 96%) (P < .001), respectively. Mean qualitative scores ranked SD images as higher quality than RD series images, and ASIR-V ranked higher than ASIR and Veo 3.0. Conclusion CT evaluation of colorectal liver metastases is compromised with modest radiation dose reduction, and the use of iterative reconstructions could not maintain observer performance. © RSNA, 2018.

来源:Radiology,查看原文。版权归原作者所有。

引用

  1. Jensen CT, Wagner-Bartak NA, Vu LN, et al. Detection of Colorectal Hepatic Metastases Is Superior at Standard Radiation Dose CT versus Reduced Dose CT. Radiology. 2018. PMID: 30480489. doi:10.1148/radiol.2018181657

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。