二维胎儿生物测量自动化工具评估

Evaluation of automated tool for two-dimensional fetal biometry.
PubMed 文献 · Ultrasound Obstet Gynecol · 2019-10-07

研究纳入100例20至40周单胎妊娠,在891张冻结二维超声图像上评估自动化工具识别结构并放置游标测量头围、腹围和股骨长的能力。自动游标53.3%无需调整,35.6%需小调整,10.1%需大调整;自动测量与手动测量误差小但存在低估偏倚。

要点

  • 自动工具在99%的冻结图像中正确识别目标生物测量变量,腹围有9张未能放置游标。
  • 自动游标主观质量评估:53.3%临床可接受,35.6%需小调整,10.1%需大调整。
  • 自动测量与手动测量相比存在低估偏倚,头围百分比误差-0.81%,腹围2.40%,股骨长3.76%。

核心结论

  • 自动化工具在99%的冻结图像中正确识别目标生物测量变量,测量准确度高,与既往发表的手动-手动一致性相当;测量存在偏倚,自动工具低估生物测量值,可通过算法进一步改进克服,但手动校正的可调游标仍是必需的。

研究设计与样本

  • 在100例20至40周单胎妊娠中行超声检查,每例每种生物变量在三张不同图像上测量共九次独立采集;排除1例因图像缺失后,分析99例妊娠共891张图像(每种变量297张);使用算法(Philips Research)检测感兴趣结构并自动放置游标,与实时手动测量比较。

诊断标准与关键数值

  • 自动游标主观临床评估分类为「临床可接受」、「需小调整」、「需大调整」,分别占475张(53.3%)、317张(35.6%)、90张(10.1%);头围自动与手动测量平均误差-0.21 cm,百分比误差-0.81%,95%一致性界限-3.73%至2.12%;腹围平均误差0.72 cm,百分比误差2.40%,95%一致性界限-9.48%至14.27%;股骨长平均误差0.21 cm,百分比误差3.76%,95%一致性界限-8.38%至15.91%。

临床应用与阅片要点

  • 自动化工具在冻结二维超声图像上可识别头围、腹围和股骨长等生物测量变量并自动放置游标,但腹围有9张图像未能放置游标;自动游标中53.3%临床可接受,35.6%需小调整,10.1%需大调整;自动测量存在低估偏倚,可调游标手动校正仍是必需。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: To evaluate whether an automated tool can recognize a structure of interest and measure fetal head circumference (HC), abdominal circumference (AC) and femur length (FL) on frozen two-dimensional ultrasound images.

METHODS: Ultrasound examinations were performed in 100 singleton pregnancies between 20 and 40 weeks of gestation, ensuring an even distribution throughout gestational age. In each pregnancy, three standard biometric variables (HC, AC, FL) were measured each in three different images obtained for this purpose (i.e. nine independent image acquisitions). An algorithm (Philips Research) was used to detect the structure of interest and automatically place calipers for measurement. Caliper placement was assessed in two ways. First, subjective clinical assessment was performed to determine whether the caliper placement was correct, and caliper position was classified as 'acceptable for clinical use', 'minor adjustment required' or 'major adjustment required'. Second, the resulting automatic measurements were compared with manual measurements, taken in real time. Mean difference errors were calculated and expressed as percentages to correct for fetal growth with advancing gestation.

RESULTS: After exclusion of one pregnancy due to missing images, a total of 891 images (297 for each biometric variable) from 99 pregnancies were analyzed. The algorithm failed to place calipers for the AC in nine images, whereas there were no failures in caliper placement for measurement of HC and FL. On subjective quality assessment of automatic caliper placement, in 475 (53.3%) images position of the calipers was judged to be clinically acceptable and did not require any adjustment, while in 317 (35.6%) and 90 images (10.1%) minor and major adjustments were required, respectively. The mean error between manual and automatic measurement of HC was -0.21 cm corresponding to a percentage error of -0.81% with 95% limits of agreement (LOA) between -3.73% and 2.12%. For AC and FL measurements, the mean error was, respectively, 0.72 cm (percentage error, 2.40%) with LOA between -9.48% and 14.27%, and 0.21 cm (percentage error, 3.76%) with LOA between -8.38% and 15.91%.

CONCLUSIONS: The automated tool identified correctly the biometric variable of interest in 99% of frozen images. The resulting measurements had a high degree of accuracy and compared well with previously published manual-to-manual agreement. The measurements exhibited bias, with the automated tool underestimating biometry; this could be overcome by further improvements in the algorithm. Nevertheless, adjustable calipers for manual correction remains a requirement. Copyright © 2018 ISUOG. Published by John Wiley & Sons Ltd.

来源:Ultrasound Obstet Gynecol,查看原文。版权归原作者所有。

引用

  1. Salim I, Cavallaro A, Ciofolo-Veit C, et al. Evaluation of automated tool for two-dimensional fetal biometry. Ultrasound Obstet Gynecol. 2019. PMID: 30478919. doi:10.1002/uog.20185

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。