文献速递腹部外周血管US

肝动脉痉挛对大鼠肝缺血再灌注损伤模型的影响

Effect of Hepatic Artery Spasm on a Rat Model of Hepatic Ischemia-Reperfusion Injury.
PubMed 文献 · J Ultrasound Med · 2018-10-30

研究通过超声观察大鼠肝缺血再灌注损伤后肝动脉血流动力学变化,并探讨酚妥拉明预处理的保护作用。50只大鼠分为假手术组、缺血再灌注对照组和酚妥拉明预处理组,再灌注后30分钟和90分钟行彩色多普勒血流成像和超声造影。结果显示对照组再灌注后30分钟肝动脉阻力指数高于假手术组,酚妥拉明组肝动脉阻力和肝微循环优于对照组,转氨酶水平显著降低。

要点

  • 肝缺血再灌注损伤过程中肝动脉可发生短暂痉挛,表现为阻力指数升高。
  • 超声可用于评估肝缺血再灌注损伤后肝动脉血流动力学变化。
  • 酚妥拉明预处理可减轻肝动脉痉挛、改善肝灌注并降低转氨酶水平。

核心结论

  • 肝缺血再灌注损伤过程中肝动脉可发生短暂痉挛并加重肝损伤;酚妥拉明治疗可通过改善肝微循环减轻肝动脉痉挛、改善肝灌注并减少肝损伤。

研究设计与样本

  • 50只大鼠随机分为假手术组(n=10)、缺血再灌注对照组(n=20)和酚妥拉明预处理组(n=20),每组于再灌注后30分钟(n=10)和90分钟(n=10)行彩色多普勒血流成像和超声造影,并检测血清丙氨酸氨基转移酶和天冬氨酸氨基转移酶水平及肝组织病理学。

关键影像表现/征象

  • 对照组再灌注后30分钟肝动脉阻力高于假手术组(平均阻力指数±标准差,0.65±0.09 vs 0.50±0.09;P<.01)。
  • 对照组再灌注后30分钟肝动脉阻力高于再灌注后90分钟(阻力指数,0.65±0.09 vs 0.50±0.08;P<.01)。
  • 酚妥拉明组再灌注后30分钟肝动脉阻力和肝微循环优于对照组(阻力指数,0.54±0.09 vs 0.65±0.09;P<.05;达峰时间,31.94±2.02秒 vs 48.34±4.74秒;P<.01)。
  • 与对照组相比,酚妥拉明组再灌注后30分钟天冬氨酸氨基转移酶和丙氨酸氨基转移酶水平显著降低(P<.05)。
  • 病理检查显示对照组肝动脉直径较小且血管壁受压。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: To investigate hemodynamic changes in the hepatic artery after hepatic ischemia-reperfusion injury (IRI) in rats via ultrasound (US) imaging and to discuss the protective effect of phentolamine (PHT) pretreatment on hepatic IRI.

METHODS: Fifty rats were randomly divided into 3 groups: a sham operation group (n = 10), a control ischemia-reperfusion group (n = 20), and a PHT pretreatment group (n = 20). Color Doppler flow imaging and contrast-enhanced US examinations were performed in each group at 30 minutes (n = 10) and 90 minutes (n = 10) after reperfusion. Blood samples were obtained to analyze serum alanine aminotransferase and aspartate aminotransferase levels, and liver tissue specimens were collected for pathologic analysis.

RESULTS: Using US, we found that hepatic artery resistance at 30 minutes after reperfusion in the control group was higher than that in the sham group (mean resistive index [RI] ± SD, 0.65 ± 0.09 versus 0.50 ± 0.09; P < .01), which was higher at 30 than 90 minutes (RI, 0.65 ± 0.09 versus 0.50 ± 0.08; P < .01) after reperfusion in the control group. However, the hepatic artery resistance and liver microcirculation in the PHT group were better than those in the control group at 30 minutes after reperfusion (RI, 0.54 ± 0.09 versus 0.65 ± 0.09; P < .05; time to peak, 31.94 ± 2.02 versus 48.34 ± 4.74 seconds; P < .01). Compared to the control group, the aspartate aminotransferase and alanine aminotransferase levels were significantly lower at 30 minutes after reperfusion in the PHT group (P < .05). A pathologic examination revealed a smaller hepatic artery diameter and a depressed vessel wall in the control group.

CONCLUSIONS: The hepatic artery can undergo a transient spasm during the hepatic IRI process, which can exacerbate liver damage. Phentolamine treatment can alleviate hepatic artery spasms, improve liver perfusion, and reduce liver injury by ameliorating the hepatic microcirculation.

来源:J Ultrasound Med,查看原文。版权归原作者所有。

引用

  1. Tang H, Qu EZ, Li K, et al. Effect of Hepatic Artery Spasm on a Rat Model of Hepatic Ischemia-Reperfusion Injury. J Ultrasound Med. 2018. PMID: 30378156. doi:10.1002/jum.14726

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。