断层弹性成像用于评估儿童非酒精性脂肪性肝病
前瞻性纳入50例经活检证实非酒精性脂肪性肝病的青少年(10–17岁),采用30–60 Hz多频磁共振弹性成像及断层弹性成像后处理获得剪切波速度c与穿透率a,并用Dixon法测定肝脂肪分数。c和a分别独立反映纤维化与脂肪变,对≥F2、≥F3纤维化及≥S2、S3脂肪变的AUC均达0.87–0.91。作者结论为一次mMRE测量可提供两个独立参数,对儿童NAFLD中重度纤维化和中重度脂肪变具有很好的诊断准确性。
要点
- 剪切波速度c独立反映纤维化,对≥F2、≥F3纤维化AUC分别为0.91、0.90。
- 穿透率a独立反映脂肪变,对≥S2、S3脂肪变AUC均为0.87。
- 一次多频磁共振弹性成像测量可同时获得c和a两个独立参数。
核心结论
- 一次mMRE测量提供2个独立参数,在儿童NAFLD中检测中度及进展期纤维化、中度及重度脂肪变具有很好的诊断准确性。
研究设计与样本
- 前瞻性研究,纳入50例经活检证实NAFLD的青少年,年龄10–17岁,平均BMI 33.9 kg/m²(范围21.4–42.1 kg/m²)。
- 采用30–60 Hz外部多频振动行多频磁共振弹性成像,经断层弹性成像后处理获得穿透率a和剪切波速度c。
- 以Dixon法测定肝脂肪分数,并以受试者工作特征曲线分析评估mMRE对肝脂肪变分级和肝纤维化分期的诊断准确性。
诊断标准与关键数值
- 剪切波速度c检测任何(≥F1)纤维化的AUC为0.79(95%CI 0.66–0.92)。
- 剪切波速度c检测中度(≥F2)纤维化的AUC为0.91(95%CI 0.83–0.99)。
- 剪切波速度c检测进展期(≥F3)纤维化的AUC为0.90(95%CI 0.80–0.99)。
- 穿透率a检测中度(≥S2)脂肪变的AUC为0.87(95%CI 0.76–0.97)。
- 穿透率a检测重度(S3)脂肪变的AUC为0.87(95%CI 0.77–0.96)。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: Today, nonalcoholic fatty liver disease (NAFLD) is the most common chronic liver disease in children and adults alike. Yet, the noninvasive evaluation of disease severity remains a diagnostic challenge. In this study, we apply multifrequency magnetic resonance elastography (mMRE) for the quantification of liver steatosis and fibrosis in adolescents with NAFLD.
METHODS: Fifty adolescents (age range, 10-17 years; mean BMI, 33.9 kg/m; range, 21.4-42.1 kg/m) with biopsy-proven NAFLD were included in this prospective study. Multifrequency magnetic resonance elastography was performed using external multifrequency vibrations of 30 to 60 Hz and tomoelastography postprocessing, resulting in penetration rate (a) and shear wave speed (c). Hepatic fat fraction was determined using Dixon method. The diagnostic accuracy of mMRE in grading liver steatosis and staging liver fibrosis was assessed by receiver operating characteristic curve analysis.
RESULTS: Multifrequency magnetic resonance elastography parameters c and a were independently sensitive to fibrosis and steatosis, respectively, providing area under the receiver operating characteristic values of 0.79 (95% confidence interval [CI], 0.66-0.92), 0.91 (95% CI, 0.83-0.99), and 0.90 (95% CI, 0.80-0.99) for the detection of any (≥F1), moderate (≥F2), and advanced (≥F3) fibrosis, and 0.87 (95% CI, 0.76-0.97) and 0.87 (95% CI, 0.77-0.96) for the detection of moderate (≥S2) and severe (S3) steatosis.
CONCLUSIONS: One mMRE measurement provides 2 independent parameters with very good diagnostic accuracy in detecting moderate and advanced fibrosis as well as moderate and severe steatosis in pediatric NAFLD.
引用
- Hudert CA, Tzschätzsch H, Rudolph B, et al. Tomoelastography for the Evaluation of Pediatric Nonalcoholic Fatty Liver Disease. Invest Radiol. 2019. PMID: 30444796. doi:10.1097/RLI.0000000000000529