迭代重建算法在双能计算机断层扫描评估心肌梗死中的作用

Role of Iterative Reconstruction Algorithm for the Assessment of Myocardial Infarction with Dual Energy Computed Tomography.
PubMed 文献 · Acad Radiol · 2018-11-12

本研究前瞻性纳入有既往心肌梗死病史的稳定患者,在同一周内行延迟强化心脏磁共振(DE-CMR)和延迟强化双能心脏CT(DE-DECT),DE-DECT分别采用0%和60%自适应统计迭代重建(ASIR)重建。结果显示DE-DECT与DE-CMR一致识别出18例(80%)心肌梗死,ASIR提高了信噪比,但诊断性能、图像质量和诊断信心均无显著改善。

要点

  • DE-DECT采用60% ASIR时,以超过199 HU为阈值检测心肌梗死节段,敏感度67%、特异度92%。
  • ASIR提高DE-DECT信噪比(0% ASIR 6.07±2.1 vs 60% ASIR 11.1±4.5,P<0.0001)。
  • ASIR对诊断性能(AUC 0.86 vs 0.83,P=0.10)、图像质量(3.35±1.2 vs 3.55±1.1,P=0.10)和诊断信心(4.40±0.9 vs 4.60±0.8,P=0.10)无显著改善。

核心结论

  • 在有既往心肌梗死病史的稳定患者中,DE-DECT与DE-CMR相比可准确检测心肌梗死,ASIR提高了DE-DECT的信噪比,但诊断性能仅呈非显著性改善。

研究设计与样本

  • 前瞻性研究,纳入有既往心肌梗死病史的稳定患者,在同一周内行DE-CMR和DE-DECT检查,DE-DECT图像分别采用0%和60% ASIR重建,以DE-CMR作为参考标准。

关键影像表现/征象

  • DE-CMR和DE-DECT均识别出18例(80%)患者存在心肌梗死。
  • 按节段分析,DE-DECT加与不加ASIR的诊断性能无显著差异(AUC 0.86 vs 0.83,P=0.10)。
  • ASIR提高DE-DECT信噪比(0% ASIR 6.07±2.1 vs 60% ASIR 11.1±4.5,P<0.0001)。
  • 心肌梗死图像质量(3.35±1.2 vs 3.55±1.1,P=0.10)和诊断信心(4.40±0.9 vs 4.60±0.8,P=0.10)无显著改善。

诊断标准与关键数值

  • DE-DECT采用60% ASIR时,以超过199 HU为阈值检测心肌梗死节段,敏感度67%、特异度92%。

临床应用与阅片要点

  • DE-DECT可用于稳定患者的延迟强化心肌梗死评估,ASIR可提高信噪比但诊断性能改善不显著。
  • 以超过199 HU为阈值时,特异度较高(92%)而敏感度有限(67%),阅片时需结合其他征象。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

RATIONALE AND OBJECTIVES: Low monochromatic energy levels (40 keV) derived from delayed enhancement dual energy cardiac computed tomography (DE-DECT) allow the evaluation of myocardial infarcts (MI) among stable patients, although at the expense of high image noise. We explored whether the application of adaptive statistical iterative reconstruction (ASIR) to 40-keV DE-DECT (unavailable with previous software versions) might improve image quality and detection of MI in stable patients.

MATERIALS AND METHODS: We prospectively enrolled patients with a history of previous MI, and performed delayed-enhancement cardiac magnetic resonance (DE-CMR) and DE-DECT within the same week. DE-DECT images were reconstructed with 0% and 60% ASIR.

RESULTS: MI was identified in 18 (80%) patients with both DE-CMR and DE-DECT. On a per segment basis, we did not identify significant differences regarding the diagnostic performance of DE-DECT with and without ASIR [area under receiver operating characteristic curve 0.86 vs. 0.83, p = 0.10]. The application of ASIR improved the signal-to-noise ratio of DE-DECT with 0% ASIR compared to DE-DECT with 60% ASIR (6.07 ± 2.1 vs. 11.1 ± 4.5, p < 0.0001). However, qualitative assessment of MI image quality (3.35 ± 1.2, vs. 3.55 ± 1.1, p = 0.10) and diagnostic confidence (4.40 ± 0.9 vs. 4.60 ± 0.8, p = 0.10) were not significantly improved. Using DE-DECT with 60% ASIR, a threshold over 199 HU showed a sensitivity of 67% and a specificity of 92% for the detection of segments with MI.

CONCLUSION: In this study, DE-DECT allowed accurate detection of MI among stable patients compared with DE-CMR, and the application of ASIR improved signal-to-noise ratio of DE-DECT, although the diagnostic performance showed only non-significant improvements.