文献速递心血管CT

基于半自动三维阈值的心脏CT左心室质量定量分析的技术可行性

Technical feasibility of semiautomatic three-dimensional threshold-based cardiac computed tomography quantification of left ventricular mass.
PubMed 文献 · Pediatr Radiol · 2018-11-23

研究纳入99例患者,采用半自动三维阈值法在心脏CT上定量左心室质量和心室容积,比较收缩末期与舒张末期的左心室质量值,并在明确、临界和无左心室肥厚三组间比较容积参数,同时评估可重复性。结果显示无技术失败,两次测量左心室质量平均差异为2.3±1.1%,收缩末期标化质量值显著高于舒张末期(71.4±42.9 g/m2 vs. 65.9±43.3 g/m2,P<0.001),明确肥厚组标化质量值显著高于临界组和无肥厚组,后两组间无统计学显著差异。结论认为该半自动三维阈值分割方法可行且可重复性高。

要点

  • 半自动三维阈值心脏CT定量左心室质量无技术失败,两次测量平均差异仅2.3±1.1%。
  • 收缩末期标化左心室质量值显著高于舒张末期(71.4±42.9 g/m2 vs. 65.9±43.3 g/m2,P<0.001),两者相关性R=0.99。
  • 明确左心室肥厚组标化质量值显著高于临界组和无肥厚组,临界组与无肥厚组间无统计学显著差异。

核心结论

  • 基于半自动三维阈值分割的心脏CT左心室质量定量可行,可重复性高,其质量值及与心室容积的比值可用于不同程度左心室肥厚患者。

研究设计与样本

  • 研究纳入99例患者,采用心脏CT半自动三维阈值法定量心室容积和质量,比较收缩末期与舒张末期的左心室质量值,并在明确、临界和无左心室肥厚三组间比较容积参数,评估可重复性,统计方法包括t检验、单因素方差分析和Pearson相关。

诊断标准与关键数值

  • 两次测量左心室质量平均差异为2.3±1.1%(均值±标准差)。
  • 收缩末期标化质量值71.4±42.9 g/m2 vs. 舒张末期65.9±43.3 g/m2,收缩末期显著更高(P<0.001),相关性R=0.99(P<0.001)。
  • 明确肥厚组标化质量值83.5±41.3 g/m2,显著高于临界组64.7±26.9 g/m2和无肥厚组55.6±23.9 g/m2(P<0.03);临界组与无肥厚组间无统计学显著差异(P>0.05)。
  • 左心室容积-质量比和质量-容积比可在三组中计算。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

BACKGROUND: Semiautomatic three-dimensional (3-D) threshold-based cardiac computed tomography (CT) quantification has not been attempted for left ventricular mass.

OBJECTIVE: To evaluate the technical feasibility of semiautomatic 3-D threshold-based cardiac CT quantification of left ventricular mass in patients with various degrees of left ventricular hypertrophy.

MATERIALS AND METHODS: In 99 patients, cardiac CT was utilized to quantify ventricular volume and mass by using a semiautomatic 3-D threshold-based method. Left ventricular mass values were compared between the end-systole and the end-diastole. Volumetric parameters were compared among three left ventricular hypertrophy groups (definite, borderline, none). The reproducibility was assessed. The t-test, one-way analysis of variance and Pearson correlation were used.

RESULTS: There were no technical failures. The left ventricular mass between the two sessions exhibited a small mean difference of 2.3±1.1% (mean±standard deviation). The indexed mass values were significantly higher at the end-systole than at the end-diastole (71.4±42.9 g/m2 vs. 65.9±43.3 g/m2, P<0.001), with significant correlation (R=0.99, P<0.001). The definite group (83.5±41.3 g/m2) showed statistically significantly higher indexed mass values than the borderline and none groups (64.7±26.9 and 55.6±23.9 g/m2, respectively; P<0.03), while demonstrating no statistically significant difference between the latter two groups (P>0.05). Left ventricular volume-mass and mass-volume ratios could be calculated in all three groups.

CONCLUSION: CT quantification of left ventricular mass using semiautomatic 3-D threshold-based segmentation is feasible with high reproducibility and the mass values and its ratios with ventricular volumes may be used in patients with various degrees of left ventricular hypertrophy.

来源:Pediatr Radiol,查看原文。版权归原作者所有。

引用

  1. Goo HW. Technical feasibility of semiautomatic three-dimensional threshold-based cardiac computed tomography quantification of left ventricular mass. Pediatr Radiol. 2018. PMID: 30470863. doi:10.1007/s00247-018-4303-9

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。