纵向与心尖四腔切面胎儿斑点追踪超声心动图比较:组织运动瓣环位移与节段纵向应变

Comparison of Longitudinal and Apical Foetal Speckle Tracking Echocardiography Using Tissue Motion Annular Displacement and Segmental Longitudinal Strain.
PubMed 文献 · Ultrasound Med Biol · 2018-10-25

这项前瞻性先导研究在57例20至40周正常胎儿中比较纵向与心尖四腔切面的胎儿斑点追踪超声心动图,采用组织运动瓣环位移与节段纵向应变评估不同步与应变。心尖切面TMAD测值系统性地大于SLS,纵向切面两种工具无差异;SLS应变在左右心室均随切面不同而显著不同,TMAD在不同切面间差异大且自动追踪准确性降低,作者认为不推荐TMAD用于胎儿斑点追踪超声心动图。

要点

  • 心尖四腔切面TMAD测得的不同步指标系统性大于SLS(p<0.001)。
  • SLS测得的左、右心室应变在纵向与心尖切面间均存在显著差异。
  • TMAD自动追踪算法准确性降低,限制数据质量,作者不推荐其用于胎儿STE。

核心结论

  • 心尖切面TMAD不同步测值系统性大于SLS,纵向切面两工具无差异;SLS应变随切面不同而变化,TMAD在不同切面间差异大且自动追踪准确性降低,作者认为不能推荐TMAD用于胎儿STE。

研究设计与样本

  • 前瞻性先导研究(探索性分析),纳入57例20至40周正常胎儿,比较纵向与心尖四腔切面的胎儿斑点追踪超声心动图,使用离线定量软件QLab Version 10.3(Philips Medical Systems,Andover,MA,USA)。

诊断标准与关键数值

  • 心尖切面TMAD测得的不同步指标系统性大于SLS(p<0.001),纵向切面无差异(p=0.153)。
  • SLS不同步在两种切面间结果相似(组内相关系数[ICC]=0.281,p=0.623)。
  • SLS左心室应变在两切面间差异显著(ICC=-0.082,p=0.011),右心室亦显著(ICC=-0.061,p=0.024)。
  • TMAD不同步在纵向与心尖评估间差异大(ICC=-0.060,p=0.03)。

临床应用与阅片要点

  • SLS的不同步评估受胎儿体位影响小于TMAD。
  • SLS应变读数随评估切面不同而变化。
  • TMAD自动追踪算法准确性降低,限制数据质量,作者不推荐TMAD用于胎儿STE。

局限性

  • 本研究为前瞻性先导研究,采用探索性分析。
  • TMAD的自动追踪算法准确性降低,限制了数据质量。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

The aim of our prospective pilot study with exploratory analysis was to compare longitudinal and apical foetal speckle tracking echocardiography (STE) using tissue motion annular displacement (TMAD) and segmental longitudinal strain (SLS). We compared two different STE quantification tools in a longitudinal and apical four-chamber view in 57 normal foetuses between 20 and 40 wk of gestation. Myocardial mechanical dyssynchrony and strain were assessed using offline quantification software (QLab Version 10.3, Philips Medical Systems, Andover, MA, USA). We compared the dyssynchrony measurements with TMAD and SLS in longitudinal and apical four-chamber views. Furthermore, we examined the segmental strain values of both ventricles with SLS and compared the differences between longitudinal and apical measurements. Dyssynchrony measurements with TMAD and SLS and strain measurements with SLS were feasible in all cases. In the apical view, the dyssynchrony measurements with TMAD were systematically greater than those achieved with SLS (p < 0.001). For the longitudinal view, no differences were observed between tools (p = 0.153). The application of SLS provided similar results for dyssynchrony in both views (intra-class correlation coefficient [ICC] = 0.281, p = 0.623), but the strain measurements in the left and right ventricles differed significantly between views (ICC = -0.082, p = 0.011, and ICC = -0.061, p = 0.024, respectively). For TMAD, we found large differences in the dyssynchrony values between longitudinal and apical assessment (ICC = -0.060, p = 0.03). Furthermore, TMAD exhibited reduced accuracy in the system's automatic tracking algorithm, limiting the data quality. The dyssynchrony assessment is affected less by the foetal position in SLS than in TMAD. The strain readings in SLS varied depending on the view in which they were assessed. The application of TMAD cannot be recommended for foetal STE.

来源:Ultrasound Med Biol,查看原文。版权归原作者所有。