低剂量动态CT心肌灌注衍生的冠状动脉CT血管造影的图像质量与诊断准确性:与侵入性冠状动脉造影对照的可行性研究
前瞻性纳入急性心肌梗死并成功再灌注治疗的患者,以紧急侵入性冠状动脉造影为参考标准,评估第三代双源CT动态心肌灌注成像衍生冠状动脉CT血管造影(CCTACT-MPI)检测显著冠状动脉狭窄(直径狭窄≥50%)的诊断性能。CCTACT-MPI平均辐射剂量3.2±1.1 mSv,93.5%的节段图像质量可判读;基于患者、血管和节段的诊断准确率分别为92.3%、83.6%和85.8%,检测≥50%狭窄的AUC分别为0.833、0.843和0.822。
要点
- 动态CT心肌灌注衍生的CCTA平均辐射剂量为3.2±1.1 mSv,93.5%的节段图像质量可判读(Likert评分2-4分)。
- 以侵入性冠状动脉造影为参考,CCTACT-MPI检测≥50%狭窄的患者水平AUC为0.833,血管水平AUC为0.843,节段水平AUC为0.822。
- 基于患者、血管和节段的诊断准确率分别为92.3%、83.6%和85.8%。
核心结论
- 动态CT心肌灌注衍生的CCTACT-MPI以侵入性冠状动脉造影为参考,能够准确诊断阻塞性冠状动脉狭窄。
研究设计与样本
- 前瞻性纳入急性心肌梗死并成功再灌注治疗的患者,最终分析26例患者共352个节段。
- 采用第三代双源CT行动态CT心肌灌注成像并衍生冠状动脉CT血管造影(CCTACT-MPI),以紧急侵入性冠状动脉造影(ICA)为参考标准。
- 评估CCTACT-MPI检测显著冠状动脉狭窄(直径狭窄≥50%)的诊断性能,并评估辐射剂量和图像质量。
关键影像表现/征象
- CCTACT-MPI总体93.5%的节段可判读(Likert评分2-4分),6.5%的节段不可诊断(Likert评分1分)。
诊断标准与关键数值
- 显著冠状动脉狭窄定义为直径狭窄≥50%,以侵入性冠状动脉造影为参考标准。
- CCTACT-MPI诊断≥50%狭窄的患者水平AUC为0.833,血管水平AUC为0.843,节段水平AUC为0.822。
- CCTACT-MPI基于患者、血管和节段的诊断准确率分别为92.3%、83.6%和85.8%。
- CCTACT-MPI诊断≥50%狭窄:22例患者共84个节段诊断为存在狭窄,268个节段无阻塞性狭窄。
- CCTACT-MPI衍生自动态CT-MPI的平均辐射剂量为3.2±1.1 mSv。
临床应用与阅片要点
- 原文未据此给出推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: To investigate the diagnostic performance of coronary CT angiography derived from dynamic CT myocardial perfusion imaging (CCTACT-MPI) by third-generation dual-source CT with reference to invasive coronary angiography (ICA).
MATERIALS AND METHODS: Patients with acute myocardial infarction and those who received successful reperfusion treatment were prospectively enrolled. Emergent ICA findings were used as the reference standard to assess the diagnostic performance of CCTACT-MPI for detection of significant coronary stenosis (diameter stenosis ≥ 50%). The radiation dose as well as image quality of CCTACT-MPI was also assessed.
RESULTS: Twenty-six patients with 352 segments were ultimately included for analysis. The mean radiation dose of CCTACT-MPI generated from dynamic CT-MPI was 3.2 ± 1.1 mSv. Overall, 93.5% of total segments were interpretable (Likert score 2-4) whereas 6.5% segments were non-diagnostic (Likert score 1). Twenty-two patients with 84 segments were diagnosed by CCTACT-MPI as having ≥ 50% stenosis presence, whereas 268 segments had no obstructive stenosis. Compared to ICA findings, the overall diagnostic accuracy of CCTACT-MPI of patient-based and vessel-based as well segment-based analysis was 92.3%, 83.6%, and 85.8% respectively. As shown by ROC analysis, the AUC of CCTACT-MPI for detection of ≥ 50% stenosis was 0.833 on a per-patient level, 0.843 on a per-vessel level, and 0.822 on a per-segment level.
CONCLUSIONS: CCTACT-MPI derived from dynamic CT-MPI was able to accurately diagnose obstructive coronary stenosis with reference to ICA.
KEY POINTS: • CCTA derived from dynamic CT-MPI had a diagnostic image quality in 93.5% of total segments. • CCTA derived from dynamic CT-MPI was accurate in diagnosing obstructive CAD compared to ICA. • The mean radiation dose of dynamic CT-MPI for reconstruction of CCTA was 3.2 mSv.
引用
- Dai X, Yu M, Pan J, et al. Image quality and diagnostic accuracy of coronary CT angiography derived from low-dose dynamic CT myocardial perfusion: a feasibility study with comparison to invasive coronary angiography. Eur Radiol. 2018. PMID: 30413956. doi:10.1007/s00330-018-5777-4
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。