胎儿镜下脊髓脊膜膨出产前手术修复过程中脐动脉与静脉导管的血流多普勒变化
回顾性分析2014至2017年单中心35例胎儿镜下脊髓脊膜膨出修复术中15例可获取多普勒数据的胎儿,发现脐动脉可出现短暂舒张末期血流缺失(75%)甚至反向(41.7%),静脉导管仅表现为搏动指数升高且无心房收缩期血流缺失或反向;这些异常多在术中不同阶段出现并于术后第1天全部消退,其临床意义尚不明确。
要点
- 胎儿镜下脊髓脊膜膨出修复术中脐动脉可短暂出现舒张末期血流缺失或反向,静脉导管无血流缺失或反向。
- 脐动脉舒张末期血流缺失最早出现时机包括胎儿镜修复中、子宫外置后注气前、子宫复位后关皮前及注气后修复开始前。
- 多数脐动脉和静脉导管多普勒异常在术中或术后第1天消退。
核心结论
- 胎儿镜下脊髓脊膜膨出修复术中可见脐动脉短暂多普勒异常而静脉导管无显著改变,这些发现的临床意义因短暂、间歇性而不明确。
研究设计与样本
- 回顾性研究,单中心2014至2017年35例胎儿镜下脊髓脊膜膨出修复术中15例有多普勒数据,分析术中超声图像,将多普勒改变时间与手术阶段匹配。
关键影像表现/征象
- 12例有脐动脉数据的胎儿中9例(75%)出现短暂舒张末期血流缺失,其中5例(41.7%)进展为舒张末期血流反向。
- 13例有静脉导管数据的胎儿中9例搏动指数升高,但无一例出现心房收缩期血流缺失或反向。
- 9例脐动脉舒张末期血流缺失中,5例(55.6%)首次出现于胎儿镜修复过程中,2例(22.2%)于子宫外置后注气前,1例(11.1%)于子宫复位后关皮前,1例(11.1%)于注气后修复开始前。
局限性
- 本研究为回顾性研究。
- 研究于单中心进行。
- 35例胎儿镜下脊髓脊膜膨出修复术中仅15例有多普勒数据。
- 这些多普勒异常的临床意义因短暂、间歇性而不明确。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE: Cardiac dysfunction has been described in 60% of fetuses undergoing open myelomeningocele (MMC) repair. Routine Doppler evaluation of the umbilical artery (UA) and ductus venosus (DV) is challenging during fetal surgery. The aim of this study was to describe Doppler changes in the UA and DV in a cohort of fetuses during fetoscopic MMC repair.
METHODS: This was a retrospective study of fetuses that underwent fetoscopic repair of MMC at a single institution between 2014 and 2017. Ultrasound images taken intraoperatively were analyzed to describe the changes in Doppler parameters of the UA and DV during fetoscopic MMC repair. The timing of Doppler changes was matched with the phase of surgery to determine whether a pattern to their appearance could be ascertained.
RESULTS: Of the thirty-five cases of fetoscopic MMC repair performed during the study period, Doppler data were available for 15. Of these, UA Doppler data were obtained in 12 cases, and DV Doppler data were obtained in 13 cases. Of the 12 cases for which there were UA data, nine (75%) showed transient absence of end-diastolic flow (EDF), with five (41.7%) of them progressing to reversal of EDF. Of the 13 cases for which there were DV data, nine had elevated pulsatility index; however, none of them had absent or reversed blood flow during atrial contraction. Of the nine cases with absent EDF in the UA, this abnormality first appeared during fetoscopic repair in five (55.6%), after uterus exteriorization but before CO2 insufflation in two (22.2%), after uterus replacement but before skin closure in one (11.1%) and after CO2 insufflation but before the start of the MMC repair in one (11.1%). Doppler abnormalities in four fetuses with reversed EDF and in three with absent EDF resolved during surgery. Follow-up examination 1 day after surgery demonstrated resolution of UA and DV Doppler abnormalities in all fetuses.
CONCLUSION: Transient Doppler abnormalities of the UA, without significant changes in the DV, can be seen during fetoscopic MMC repair. The clinical significance of these Doppler findings remains unclear due to their transient and intermittent nature. Copyright © 2018 ISUOG. Published by John Wiley & Sons Ltd.
引用
- Kassir E, Belfort MA, Shamshirsaz AA, et al. Doppler changes in umbilical artery and ductus venosus during fetoscopic prenatal surgical repair of myelomeningocele. Ultrasound Obstet Gynecol. 2019. PMID: 30426574. doi:10.1002/uog.20174
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。