文献速递外周血管腹部CTDSA

低碘负荷虚拟单能双能腹盆腔主髂动脉CT血管成像的前瞻性随机研究

Virtual Monochromatic Dual-Energy Aortoiliac CT Angiography With Reduced Iodine Dose: A Prospective Randomized Study.
PubMed 文献 · AJR Am J Roentgenol · 2018-11-26

52例腹主髂动脉瘤患者既往接受120 kVp、33 g碘的单能CTA,随访时随机分组接受碘量减少52%的双能CTA(16.2 g组n=26,16.0 g组n=26),40与50 keV虚拟单能图像均可诊断,血管内衰减高于单能CTA,内漏检出敏感度78.9–94.7%、特异度100%。

要点

  • 40与50 keV虚拟单能图像均可满足主髂动脉诊断需求,图像质量评分与120 kVp单能CTA相当。
  • 40与50 keV图像血管内衰减显著高于标准碘量单能CTA(720±125 HU和482±82 HU vs 303±65 HU,p<0.01)。
  • 内漏检出敏感度78.9–94.7%、特异度100%,双能CTA总剂量长度乘积低于单能CTA。

核心结论

  • 约50%碘量减少(16.0与16.2 g)的低能(40与50 keV)虚拟单能双能CTA可提供足够的血管内衰减和诊断质量,适用于主髂动脉评估。

研究设计与样本

  • 前瞻性随机研究,52例腹主髂动脉瘤成人,既往行120 kVp、33 g碘单能CTA,随访行双能CTA,随机分16.2 g(270 mg I/mL,n=26)与16.0 g(320 mg I/mL,n=26)两组,采用快速管电压切换双能CT,两名读者独立以5分法评估图像质量。

关键影像表现/征象

  • 所有52例双能CTA检查均评为可诊断,图像质量评分与120 kVp单能CTA相当(40 keV为4.2–4.4,50 keV为4.6–4.8,单能CTA为4.4–4.5)。
  • 所有减碘双能CTA检查血管内衰减均匀,40与50 keV图像显著高于标准碘量单能CTA(720±125 HU和482±82 HU vs 303±65 HU,p<0.01)。
  • 16.2 g与16.0 g两组间血管内衰减无差异(p=0.82)。

诊断标准与关键数值

  • 内漏检出敏感度78.9–94.7%、特异度100%。
  • 双能CTA总剂量长度乘积为788±166 mGy·cm,低于单能CTA的1114±468 mGy·cm。

临床应用与阅片要点

  • 低能虚拟单能图像(40与50 keV)可在约50%减碘条件下用于主髂动脉CTA评估,图像质量与常规120 kVp单能CTA相当。
  • 减碘双能CTA血管内衰减均匀,40与50 keV图像衰减值高于标准碘量单能CTA,阅片时需注意能级对CT值的影响。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: The purpose of this study was to assess the feasibility of performing abdominopelvic aortoiliac CT angiography (CTA) with 16.0 g of iodine contrast medium acquired with low-energy (40 and 50 keV) virtual monochromatic (VMC) images with rapid-kilovoltage-switching dual-energy CT.

SUBJECTS AND METHODS: A total of 52 adults with abdominal aortoiliac aneurysm and prior 120-kVp single-energy CTA (SECTA) with 33 g iodine (standard dose) underwent follow-up dual-energy CTA (DECTA) with a 52% reduced iodine dose. Subjects were randomly assigned to a contrast medium protocol for DECTA examinations: one group (n = 26) received 16.2 g (270 mg I/mL) and the other (n = 26) received 16.0 g (320 mg I/mL). Two readers independently assessed SECTA and VMC DECTA datasets for image quality using a 5-point scale. Aortoiliac intravascular attenuation was measured, and ANOVA was used to compare measurements between VMC DECTA and SECTA images. In a subset of patients with DECTA after endovascular aortic repair, endoleak detection was evaluated on VMC images. Volume CT dose index, dose-length product, and size-specific dose estimate were compared between DECTA and SECTA.

RESULTS: All DECTA examinations (n = 52) were rated diagnostic with image quality scores comparable to those of 120-kVp single-energy CTA (40 keV, 4.2-4.4; 50 keV, 4.6-4.8; SECTA, 4.4-4.5). Intravascular attenuation was uniform in all reduced-iodine DECTA examinations and was significantly higher on 40- and 50-keV images than on standard-iodine-dose SECTA images (720 ± 125 HU and 482 ± 82 HU vs 303 ± 65 HU) (p < 0.01). There was no difference in intravascular attenuation between the 16.2-g and the 16.0-g doses (p = 0.82). Sensitivity and specificity for endoleak detection were 78.9-94.7% and 100%. Total dose-length product was lower for DECTA (788 ± 166 mGy · cm) than for SECTA (1114 ± 468 mGy · cm).

CONCLUSION: Low-energy VMC DECTA images (40 and 50 keV) acquired with two contrast protocols at approximately 50% reduced iodine dose (16.0 and 16.2 g) provide adequate intravascular attenuation and diagnostic quality for aortoiliac evaluation.

来源:AJR Am J Roentgenol,查看原文。版权归原作者所有。

引用

  1. Patino M, Parakh A, Lo GC, et al. Virtual Monochromatic Dual-Energy Aortoiliac CT Angiography With Reduced Iodine Dose: A Prospective Randomized Study. AJR Am J Roentgenol. 2018. PMID: 30476460. doi:10.2214/AJR.18.19935

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。