健康成人心脏MRI原生T1与细胞外容积测量:一项Meta分析
该系统综述与汇总分析纳入120篇原生T1文献(5541名健康成人)和81篇细胞外容积(ECV)文献(3872名健康成人),汇总均值显示原生T1在1.5 T为976毫秒(95%CI 969–983)、3.0 T为1159毫秒(95%CI 1143–1175),ECV在1.5 T为25.9%(95%CI 25.5%–26.3%)、3.0 T为25.9%(95%CI 25.4%–26.5%);研究间存在显著异质性(I² 90%–99%),提示需标准化心脏MRI协议并建立机构特异性参考范围。
要点
- 健康成人左心室原生T1汇总均值:1.5 T为976毫秒(95%CI 969–983),3.0 T为1159毫秒(95%CI 1143–1175)。
- 健康成人左心室ECV汇总均值:1.5 T为25.9%(95%CI 25.5%–26.3%),3.0 T为25.9%(95%CI 25.4%–26.5%)。
- 研究间异质性显著(原生T1 I²=99%,ECV I²=94%/90%),需标准化协议并建立机构特异性参考范围。
核心结论
- 本分析汇总了健康成人原生T1与ECV测量的合并均值;研究间存在显著异质性,凸显标准化心脏MRI协议及建立机构特异性参考范围的重要性。
研究设计与样本
- 系统综述与汇总分析,检索PubMed、Web of Science和Cochrane Central,纳入健康成人左心室原生T1测量文献120篇(5541名参与者,平均年龄50岁,男性51.0%[2826/5541])和ECV测量文献81篇(3872名参与者,平均年龄52岁,男性50.0%[1936/3872]),采用随机效应模型生成汇总均值,以I²评估异质性,并行亚组分析和Meta回归分析探究异质性病因。
诊断标准与关键数值
- 原生T1汇总均值在1.5 T为976毫秒(95%CI 969毫秒,983毫秒),在3.0 T为1159毫秒(95%CI 1143毫秒,1175毫秒),两个场强下I²均为99%。
- ECV汇总均值在1.5 T为25.9%(95%CI 25.5%,26.3%),在3.0 T为25.9%(95%CI 25.4%,26.5%),1.5 T和3.0 T的I²分别为94%和90%。
临床应用与阅片要点
- 作者指出研究间存在显著异质性,强调标准化心脏MRI协议和建立机构特异性参考范围的重要性。
局限性
- 原生T1测量研究间异质性I²为99%(1.5 T和3.0 T均如此)。
- ECV测量研究间异质性在1.5 T为I²=94%、在3.0 T为I²=90%。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
Purpose To summarize the literature by performing a systematic review and pooled analysis of the data, to understand the extent of variability among studies of native T1 and extracellular volume (ECV) measurements, and to identify covariates that account for heterogeneity between studies. Materials and Methods PubMed, Web of Science, and Cochrane Central were searched for native T1 and ECV measurements of the left ventricle in health adult study participants. The search terms used were "T1 mapping heart," "Native T1 heart," and "ECV heart." Summary means were generated with random-effects modeling. Heterogeneity was assessed by using the inconsistency factor (I 2). Subgroup analyses and meta-regression analyses were conducted to identify etiologic causes of heterogeneity. Results This systematic review of native T1 included 120 articles, with 5541 participants (mean age, 50 years; 51.0% men [2826 of 5541]). The pooled mean of native T1 was 976 msec (95% confidence interval [CI]: 969 msec, 983 msec) at 1.5 T and 1159 msec (95% CI: 1143 msec, 1175 msec) at 3.0 T. I 2 was 99% at both field strengths. Eighty-one articles were included in the systematic review of ECV, with 3872 participants (mean age, 52 years; 50.0% men [1936 of 3872]). The pooled mean of ECV was 25.9% at field strength of 1.5 T (95% CI: 25.5%, 26.3%) and 3.0 T (95% CI: 25.4%, 26.5%). I 2 was 94% and 90% at 1.5 and 3.0 T, respectively. Conclusion The pooled means of extracellular volume and native T1 measurements in healthy adult participants are summarized in this analysis. There was significant heterogeneity found among studies, highlighting the importance of standardized cardiac MRI protocols and the derivation of institution specific reference ranges. © RSNA, 2018 Online supplemental material is available for this article. See also the editorial by Dodd and Dewey in this issue.
引用
- Gottbrecht M, Kramer CM, Salerno M, et al. Native T1 and Extracellular Volume Measurements by Cardiac MRI in Healthy Adults: A Meta-Analysis. Radiology. 2018. PMID: 30422092. doi:10.1148/radiol.2018180226
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。