文献速递心血管CT

双层光谱探测器系统对对比剂肾病风险患者行低对比剂剂量冠状动脉CT血管成像

Low contrast material dose coronary computed tomographic angiography using a dual-layer spectral detector system in patients at risk for contrast-induced nephropathy.
PubMed 文献 · Br J Radiol · 2018-11-14

研究评估双层光谱探测器CT虚拟单能成像(VMI)在低对比剂剂量下冠状动脉CT血管成像的图像质量:肾功能不全患者30例采用50keV VMI协议与50%对比剂剂量(140 mgI kg-1),对照组30例无肾功能不全患者采用120 kVp与标准对比剂剂量(280 mgI kg-1)。结果显示50keV VMI组升主动脉平均CT衰减值、对比噪声比及对比增强视觉评分均显著更高,图像噪声显著更低,其他视觉图像质量参数两组间无显著差异。结论认为50keV VMI可在肾功能不全患者中将对比剂剂量减少50%而不降低冠状动脉CT血管成像图像质量。

要点

  • 肾功能不全患者采用50keV VMI与50%对比剂剂量(140 mgI kg-1)时,升主动脉CT衰减值显著高于120 kVp标准剂量组。
  • 50keV VMI组图像噪声显著更低,对比噪声比与对比增强视觉评分显著更高。
  • 其他视觉图像质量参数(图像噪声、线束硬化伪影、血管锐利度、整体图像质量)两组间无显著差异。

核心结论

  • 双层光谱探测器CT采用50keV VMI可使肾功能不全患者的对比剂剂量减少50%而不降低冠状动脉CT血管成像图像质量。

研究设计与样本

  • 研究纳入肾功能不全患者30例采用50keV VMI协议与50%对比剂剂量(140 mgI kg-1),对照组30例无肾功能不全患者采用120 kVp与标准对比剂剂量(280 mgI kg-1)。

诊断标准与关键数值

  • 视觉图像质量对对比增强、图像噪声、线束硬化伪影、血管锐利度和整体图像质量采用4分制评分。
  • 50keV VMI组升主动脉平均CT衰减值显著高于120 kVp组。
  • 50keV VMI组图像噪声显著低于120 kVp组。
  • 50keV VMI组对比噪声比和对比增强平均视觉评分显著高于120 kVp组。

局限性

  • 原文未报告局限性

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE:: To evaluate the effects of virtual monochromatic imaging (VMI) using dual-layer spectral detector CT on the image quality of coronary CT angiography (CCTA) acquired by using a low contrast material (CM) dose.

METHODS:: We used a VMI 50keV protocol with a 50% CM dose (140 mgI kg-1) to scan 30 patients with renal insufficiency and a 120 kVp with the standard CM dose (280 mgI kg-1) to scan 30 controls without renal insufficiency. Quantitative parameters, including CT attenuation, image noise, and contrast-to-noise ratio (CNR), were measured. The visual image quality factors of contrast enhancement, image noise, beam-hardening artefact, vessel sharpness, and overall image quality were scored on a 4-point scale.

RESULTS:: The mean CT attenuation of the ascending aorta was significantly higher for 50 keV VMI than for 120 kVp. Image noise was significantly lower under the 50 keV VMI. CNR and the mean visual score for contrast enhancement were significantly higher for 50 keV VMI. There were no significant differences in the other visual image quality parameters between the two protocols.

CONCLUSION:: Dual-layer spectral detector CT using 50 keV VMI enabled reducing the CM dose by 50 % without CCAT image quality degradation in patients with renal insufficiency.

ADVANCES IN KNOWLEDGE:: The VMI 50 keV protocol using dual-layer spectral detector CT and a CM dose reduced by 50 % (140 mgI kg-1) can improve the diagnostic image quality of CCTA.

来源:Br J Radiol,查看原文。版权归原作者所有。

引用

  1. Oda S, Takaoka H, Katahira K, et al. Low contrast material dose coronary computed tomographic angiography using a dual-layer spectral detector system in patients at risk for contrast-induced nephropathy. Br J Radiol. 2018. PMID: 30407841. doi:10.1259/bjr.20180215

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。