MR血管成像与二维相位对比成像评估肠系膜-Rex旁路功能
回顾性分析25例肠系膜-Rex旁路患儿,用MR血管成像测量旁路最小横截面积,用二维相位对比MRI测量旁路血流量并除以升主动脉流量以量化相对体循环血流。旁路最小面积与旁路流量显著相关(rho=0.469,P=0.018),旁路流量与血小板计数显著相关(r=0.525,P=0.021)。二维相位对比MRI可量化旁路血流,可能有助于联合MR血管成像评估旁路完整性。
要点
- 25例患儿中18例MR血管成像显示旁路横截面积狭窄>50%。
- 旁路最小横截面积与旁路流量显著相关(rho=0.469,P=0.018)。
- 旁路流量与血小板计数显著相关(r=0.525,P=0.021)。
核心结论
- 二维相位对比MRI可量化肠系膜-Rex旁路血流量相对于总体循环血流量的比值。
- 在25例患儿队列中,旁路流量与旁路最小面积及血小板计数相关。
- 二维相位对比MRI联合MR血管成像可能有助于评估旁路完整性。
研究设计与样本
- 回顾性分析接受MR血管成像和二维相位对比MRI的肠系膜-Rex旁路患儿。
- 共纳入25例儿童,中位年龄9.5岁。
- 多数患者因临床怀疑并发症而被转诊至影像检查。
- 在MR血管成像上测量旁路最小直径并计算横截面积。
- 用二维相位对比MRI测量旁路血流量,并除以升主动脉流量以量化旁路血流相对于体循环的比例。
诊断标准与关键数值
- 25例中18例MR血管成像显示旁路横截面积狭窄>50%。
- 旁路最小横截面积与旁路流量显著相关(rho=0.469,P=0.018)。
- 旁路流量与血小板计数显著相关(r=0.525,P=0.021)。
- 19例患者的平均血小板计数为127 K/μL。
临床应用与阅片要点
- 原文未据此给出推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
BACKGROUND: The meso-Rex bypass restores blood flow to the liver in patients with extrahepatic portal vein thrombosis. Stenosis occurs in some cases, causing the reappearance of portal hypertension. Complications such as thrombocytopenia present on a spectrum and there are currently no guidelines regarding a threshold for endovascular intervention. While Doppler ultrasound (US) is common for routine evaluation, magnetic resonance (MR) angiography with two-dimensional phase-contrast MRI (2-D PC-MRI) may improve the assessment of meso-Rex bypass function.
OBJECTIVES: To determine the feasibility and utility of MR angiography with 2-D PC-MRI in evaluating children with meso-Rex bypass and to correlate meso-Rex bypass blood flow to markers of portal hypertension.
MATERIALS AND METHODS: MR angiography and 2-D PC-MRI in meso-Rex bypass patients were retrospectively analyzed. Minimum bypass diameter was measured on MR angiography and used to calculate cross-sectional area. Meso-Rex bypass blood flow was measured using 2-D PC-MRI and divided by ascending aortic flow to quantify bypass flow relative to systemic circulation. Platelet and white blood cell counts were recorded. Correlation was performed between minimum bypass area, blood flow and clinical data.
RESULTS: Twenty-five children (median age: 9.5 years) with meso-Rex bypass underwent MR angiography and 2-D PC-MRI. The majority of patients were referred to imaging given clinical concern for complications. Eighteen of the 25 patients demonstrated >50% narrowing of the bypass cross-sectional area. The mean platelet count in 19 patients was 127 K/μL. There was a significant correlation between minimum cross-sectional bypass area and bypass flow (rho=0.469, P=0.018) and between bypass flow and platelet counts (r=0.525, P=0.021).
CONCLUSION: Two-dimensional PC-MRI can quantify meso-Rex bypass blood flow relative to total systemic flow. In a cohort of 25 children, bypass flow correlated to minimum bypass area and platelet count. Two-dimensional PC-MRI may be valuable alongside MR angiography to assess bypass integrity.
引用
- Stefek HA, Rigsby CK, Berhane H, et al. MR angiography and 2-D phase-contrast imaging for evaluation of meso-rex bypass function. Pediatr Radiol. 2018. PMID: 30382320. doi:10.1007/s00247-018-4284-8
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。