文献速递胸部心血管CT

平扫胸部CT诊断贫血严重程度的最佳阈值:一项初步研究

Optimal threshold for the diagnosis of anemia severity on unenhanced thoracic CT: A preliminary study.
PubMed 文献 · Eur J Radiol · 2018-10-09

该回顾性研究对317例不同贫血程度患者及正常对照的平扫胸部CT进行测量,分析右心室腔、左心室腔、室间隔及室间隔与左心室腔差值(IVS-LV)的CT衰减值,并在24小时内估测血红蛋白水平。结果显示IVS-LV CT衰减值与血红蛋白浓度明显平行相关(决定系数0.818,P<.001),按性别设定阈值可预测贫血严重程度,观察者内和观察者间信度良好(ICC均>0.99)。

要点

  • IVS-LV CT衰减值与血红蛋白浓度明显平行相关,决定系数0.818(P<.001)。
  • 男性IVS-LV CT值>13.5 HU诊断重度贫血敏感度94.7%、特异度83.6%;女性分别为82.4%、84.6%。
  • 测量重复性良好,观察者内和观察者间ICC均>0.99。

核心结论

  • IVS-LV的CT衰减值可预测贫血严重程度,敏感度和特异度良好,可为临床实践增加价值,并在血液学实验室检查缺乏时促进患者照护。

研究设计与样本

  • 回顾性分析317例不同贫血程度患者及正常患者的平扫胸部CT,测量右心室腔、左心室腔、室间隔及IVS-LV的CT衰减值,血红蛋白水平在24小时内估测,采用受试者工作特征曲线获得最佳诊断阈值,并以组内相关系数评估测量重复性。

关键影像表现/征象

  • 测量右心室腔、左心室腔、室间隔及室间隔与左心室腔差值(IVS-LV)的CT衰减值。
  • 血红蛋白浓度与IVS-LV的CT衰减值存在明显的平行相关(决定系数0.818;P<.001)。

诊断标准与关键数值

  • 男性IVS-LV CT衰减值在5.5-9.5 HU、女性在4.5-8.5 HU时,诊断轻度贫血的特异度低而敏感度很高(分别为87.1%、100%)。
  • 男性IVS-LV CT值在9.5-13.5 HU、女性在8.5-13.5 HU时,诊断中度贫血的敏感度和特异度良好(男性92.9%和74.8%;女性93.9%和60.0%)。
  • IVS-LV CT值>13.5 HU时,所有性别诊断重度贫血的敏感度和特异度均很好(男性94.7%和83.6%;女性82.4%和84.6%)。

临床应用与阅片要点

  • 作者认为IVS-LV的CT衰减值可预测贫血严重程度,敏感度和特异度良好,可为临床实践增加价值,并在血液学实验室检查缺乏时促进患者照护。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: To investigate and evaluate the value as accuracy of diagnosis different degrees of anemia through the unenhanced thoracic computed tomography (CT) scan.

MATERIALS AND METHODS: The CT attenuation of right ventricle (RV) cavity, left ventricular (LV) cavity, interventricular septum and difference between the interventricular septum and left ventricle cavity (IVS-LV) were retrospectively analyzed and measured in 317 patients with different degrees of anemia and the normal patients. The hemoglobin (Hb) level was estimated within 24 h. Statistical analysis was made to obtain the best diagnostic threshold of anemia levels by CT scan, measurement repeatability was assessed using the intra-class correlation coefficient (ICC) values.

RESULTS: An obvious parallel correlation of hemoglobin concentration and CT attenuation of IVS-LV existed (the determination coefficient was 0.818; P < .001). Based on receiver operating characteristic (ROC) curves, the conclusion was that when the threshold of CT attenuation of IVS-LV at (5.5-9.5) HU in male and (4.5-8.5) HU in female, the specificity for diagnosing mild anemia was low, while the sensitivity was very high (87.1%, 100%, respectively), if the CT value was among (9.5-13.5) HU in male or (8.5-13.5) HU in female, the sensitivity and specificity for diagnosing moderate anemia were fine (92.9% and 74.8% in male; 93.9% and 60.0% in female), and once the CT value was more than 13.5 HU the sensitivity and specificity for diagnosing severe anemia in all gender were greatly good (94.7% and 83.6% in male; 82.4% and 84.6% in female). The intra-and inter-observer reliability and reproducibility were good (ICC were all more than 0.99).

CONCLUSION: The CT attenuation of IVS-LV could predict the severity of anemia with good sensitivity and specificity, which could add value to clinical practice and more importantly facilitating patient care as hematologic laboratory investigations are lacking.

来源:Eur J Radiol,查看原文。版权归原作者所有。

引用

  1. Zhou QQ, Yu YS, Chen YC, et al. Optimal threshold for the diagnosis of anemia severity on unenhanced thoracic CT: A preliminary study. Eur J Radiol. 2018. PMID: 30396662. doi:10.1016/j.ejrad.2018.10.007

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。