儿童胸部CT中铅屏蔽:铅围裙置于扫描范围外对辐射剂量降低的影响

Lead Shielding in Pediatric Chest CT: Effect of Apron Placement Outside the Scan Volume on Radiation Dose Reduction.
PubMed 文献 · AJR Am J Roentgenol · 2018-11-13

本研究使用模拟5岁儿童体型的半仿真体模进行胸部CT扫描,在扫描范围下方1、5、10 cm处放置铅围裙,用点剂量仪测量扫描范围内外的辐射剂量。结果显示铅围裙距扫描范围越远,剂量降低幅度越小;扫描范围外的剂量降低百分比分别为19.1%、10.1%和4.3%,但相对于检查总剂量,降低幅度极小(总降低百分比分别为0.7%、0.4%、0.2%)。作者结论认为,儿童胸部CT中腹部和盆腔铅屏蔽带来的剂量降低可能不足以抵消其相关的伪影和感染风险。

要点

  • 铅围裙距扫描范围1、5、10 cm时,扫描范围外剂量降低百分比分别为19.1%、10.1%、4.3%,距离越远降低越少。
  • 包括主扫描剂量在内的总剂量降低百分比分别仅为0.7%、0.4%、0.2%,相对于检查总剂量极小。
  • 作者认为儿童胸部CT中腹部和盆腔铅屏蔽的剂量降低可能不足以抵消伪影和感染的相关风险。

核心结论

  • 铅围裙距扫描范围越远,剂量降低幅度越小;与检查总剂量相比剂量降低极小,儿童胸部CT中腹部和盆腔铅屏蔽带来的剂量降低可能不足以抵消其相关的伪影和感染潜在风险。

研究设计与样本

  • 使用模拟5岁儿童体型的头、腹、盆腔半仿真体模置于胸部体模旁,行胸部CT扫描,用点剂量仪测量扫描范围内外剂量,铅围裙置于距扫描范围底部1、5、10 cm处重复测量,计算各测量位置的加权平均剂量。

诊断标准与关键数值

  • 扫描范围内加权平均剂量为1.7 mGy,扫描范围外为0.067 mGy;铅围裙距扫描范围底部1、5、10 cm时,扫描范围外平均剂量降低分别为0.013 mGy(19.1%)、0.007 mGy(10.1%)、0.003 mGy(4.3%);包括主扫描剂量在内的总剂量降低百分比分别为0.7%、0.4%、0.2%。

临床应用与阅片要点

  • 作者结论认为,儿童胸部CT检查中腹部和盆腔铅屏蔽带来的剂量降低可能不足以抵消其相关的伪影和感染潜在风险。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: The purpose of this study was to quantify the dose reduction resulting from the use of lead aprons for pediatric chest CT as a function of the distance between the apron and the bottom of the scan range.

MATERIALS AND METHODS: Semianthropomorphic phantoms of the head, abdomen, and pelvis were placed adjacent to a chest phantom to mimic the habitus of a 5-year-old child. A chest CT scan was performed, and a point dosimeter was used to measure the radiation dose at points within and outside the scan range. A lead apron was placed 1, 5, and 10 cm from the bottom of the CT scan range, and the measurements were repeated. The weighted-average dose was calculated for each measurement position.

RESULTS: The weighted-average dose within and outside the scan range was 1.7 and 0.067 mGy, respectively. The mean (percentage) dose reduction outside the scan range resulting from use of the lead apron was 0.013 mGy (19.1%), 0.007 mGy (10.1%), and 0.003 mGy (4.3%) when the lead apron was placed at distances of 1, 5, and 10 cm from the bottom of the scan range, respectively. The corresponding total percentage dose reduction (including the dose from the primary scan) was 0.7%, 0.4%, and 0.2%, respectively.

CONCLUSION: As the lead apron was placed farther from the scan range, the amount of dose reduction diminished. The reduction in dose was extremely small compared with the overall dose from the examination. The small dose reduction gained from the use of lead shielding over the abdomen and pelvis during chest CT examination of pediatric patients may not outweigh the associated potential risks of artifacts and infection.

来源:AJR Am J Roentgenol,查看原文。版权归原作者所有。

引用

  1. Yu L, Bruesewitz MR, Vrieze TJ, et al. Lead Shielding in Pediatric Chest CT: Effect of Apron Placement Outside the Scan Volume on Radiation Dose Reduction. AJR Am J Roentgenol. 2018. PMID: 30422712. doi:10.2214/AJR.17.19405

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。