文献速递胸部介入CT

自体血封堵注射与氢凝胶封堵在CT引导肺活检中的比较:一项前瞻性随机试验

Autologous Blood Patch Injection versus Hydrogel Plug in CT-guided Lung Biopsy: A Prospective Randomized Trial.
PubMed 文献 · Radiology · 2018-11-27

该前瞻性随机对照试验采用非劣效性设计,比较自体血封堵注射(ABPI)与氢凝胶封堵在CT引导经皮肺活检后2小时内气胸发生率。ABPI组气胸率21%(42/199),氢凝胶封堵组29%(60/208),ABPI不劣于氢凝胶封堵。

要点

  • ABPI组活检后2小时内气胸率为21%(42/199),氢凝胶封堵组为29%(60/208)。
  • ABPI组置管率为9%(18/199),氢凝胶封堵组为13%(27/208)。
  • ABPI组活检后2周内延迟性气胸率为1.4%(3/199),氢凝胶封堵组为1.5%(3/208)。

核心结论

  • 自体血封堵注射在CT引导经皮肺活检后气胸发生率方面不劣于氢凝胶封堵。

研究设计与样本

  • 前瞻性随机对照试验(ClinicalTrials.gov NCT02224924),采用非劣效性设计,非劣效界值为10%,主要结局为活检后2小时内气胸发生率,设定I类错误率0.05、把握度90%,目标样本量552例(每组276例);2014年10月至2017年2月共评估2052例转诊行CT引导肺活检的潜在研究对象;最终研究组453例随机分配至ABPI组(n=226)或氢凝胶封堵组(n=227),其中407例接受了肺活检。

诊断标准与关键数值

  • ABPI组活检后2小时内气胸率为21%(42/199),氢凝胶封堵组为29%(60/208)。
  • ABPI组置管率为9%(18/199),氢凝胶封堵组为13%(27/208)。
  • ABPI组活检后2周内延迟性气胸率为1.4%(3/199),氢凝胶封堵组为1.5%(3/208)。

临床应用与阅片要点

  • 作者结论认为自体血封堵注射在CT引导经皮肺活检后气胸发生率方面不劣于氢凝胶封堵。

局限性

  • 数据安全监查委员会基于非劣效性预设提前终止标准在中期的分析后建议停止入组。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

Purpose To compare the effect of autologous blood patch injection (ABPI) with that of a hydrogel plug on the rate of pneumothorax at CT-guided percutaneous lung biopsy. Materials and Methods In this prospective randomized controlled trial ( https://ClinicalTrials.gov , NCT02224924), a noninferiority design was used for ABPI, with a 10% noninferiority margin when compared with the hydrogel plug, with the primary outcome of pneumothorax rate within 2 hours of biopsy. A type I error rate of 0.05 and 90% power were specified with a target study population of 552 participants (276 in each arm). From October 2014 to February 2017, all potential study participants referred for CT-guided lung biopsy (n = 2052) were assessed for enrollment. Results The data safety monitoring board recommended the trial be closed to accrual after an interim analysis met prespecified criteria for early stopping based on noninferiority. The final study group consisted of 453 participants who were randomly assigned to the ABPI (n = 226) or hydrogel plug (n = 227) arms. Of these, 407 underwent lung biopsy. Pneumothorax rates within 2 hours of biopsy were 21% (42 of 199) and 29% (60 of 208); chest tube rates were 9% (18 of 199) and 13% (27 of 208); and delayed pneumothorax rates within 2 weeks after biopsy were 1.4% (three of 199) and 1.5% (three of 208) in the ABPI and hydrogel plug arms, respectively. Conclusion Autologous blood patch injection is noninferior to a hydrogel plug regarding the rate of pneumothorax after CT-guided percutaneous lung biopsy. © RSNA, 2018 Online supplemental material is available for this article.

来源:Radiology,查看原文。版权归原作者所有。

引用

  1. Maybody M, Muallem N, Brown KT, et al. Autologous Blood Patch Injection versus Hydrogel Plug in CT-guided Lung Biopsy: A Prospective Randomized Trial. Radiology. 2018. PMID: 30480487. doi:10.1148/radiol.2018181140

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。