文献速递儿科影像胸部介入CT

锥形束CT导航叠加引导用于儿童经皮肺结节活检

Cone-beam computed tomography guidance with navigational overlay for percutaneous lung nodule biopsy.
PubMed 文献 · Pediatr Radiol · 2018-11-08

回顾性纳入两家三级儿童医院36例患者共37个肺结节(≤48 mm),采用锥形束CT导航叠加引导行经皮肺结节活检;32/36例(89%)获得诊断性标本,12例(33%)发生并发症,包括9例气胸(4例需胸管)、1例血胸(需胸管)和3例自限性肺出血;作者结论认为该引导方式可准确完成活检。

要点

  • 锥形束CT导航叠加引导可用于儿童经皮肺结节活检,36例中32例(89%)获得诊断性标本。
  • 并发症见于12/36例(33%),以气胸最常见(9例,其中4例需胸管)。
  • 中位年龄15.5岁(范围8个月至23岁),中位体重55 kg(范围8–97 kg)。

核心结论

  • 锥形束CT导航叠加引导下经皮肺结节针刺活检可准确完成。

研究设计与样本

  • 回顾性研究,纳入两家大型三级儿童医院连续36例患者(37个结节),结节≤48 mm,采用锥形束CT导航叠加引导行经皮肺结节活检。

诊断标准与关键数值

  • 诊断性标本获得率32/36例(89%);平均穿刺次数5次(范围2–15次)。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

BACKGROUND: Cone-beam CT is increasingly used in pediatric interventional radiology procedures. However, the feasibility or safety of using this mode of imaging guidance for percutaneous lung nodule biopsy in children has not been assessed.

OBJECTIVE: To retrospectively evaluate safety and diagnostic accuracy of percutaneous lung nodule biopsy in people treated at a pediatric hospital using cone-beam CT with navigational overlay.

MATERIALS AND METHODS: Thirty-six consecutive patients from two large tertiary-care children's hospitals with lung nodules of 48 mm or smaller underwent percutaneous lung nodule biopsy using cone-beam CT with navigational overlay. We evaluated patient demographics, pre- and post-biopsy diagnoses, number of biopsy passes, complications, radiation exposure and technical success.

RESULTS: Percutaneous lung nodule biopsy was performed for 37 nodules in 36 patients (23 males, 13 females, median age 15.5 years, range 8 months to 23 years). One patient underwent biopsy of two nodules at a single procedure. Median patient weight was 55 kg (range 8-97 kg). Pre-biopsy diagnoses included metastatic sarcoma or other solid tumor (n=11), leukemia/lymphoma (n=13), infection (n=10), chronic granulomatous disease (n=2) and post-transplant lymphoproliferative disorder (PTLD; n=1). Mean number of passes was 5 (range 2-15). Mean pre-procedure international normalized ratio (INR) was 1.1 and platelet count 193 × 109/L. Diagnostic specimens were obtained in 32 of 36 patients (89%). Thirteen complications were encountered in 12 patients (33% of cohort), including 9 pneumothoraces (4 requiring chest tubes); 1 hemothorax, which required a chest tube; and 3 self-limited pulmonary hemorrhages. Mean and median radiation doses were as follows: fluoroscopy time 3 min and 2.4 min, dose-area product (DAP) (recorded in 31 patients) 23,402 Gy·cm2 and 12,453 Gy·cm2, and air kerma 88 mGy and 58 mGy.

CONCLUSION: Percutaneous lung nodule needle biopsy can be performed accurately using cone-beam CT with navigational overlay.

来源:Pediatr Radiol,查看原文。版权归原作者所有。

引用

  1. Shivaram GM, Gill AE, Monroe EJ, et al. Cone-beam computed tomography guidance with navigational overlay for percutaneous lung nodule biopsy. Pediatr Radiol. 2018. PMID: 30411171. doi:10.1007/s00247-018-4296-4

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。