低剖面编织支架Y型支架辅助弹簧圈栓塞治疗复杂分叉部动脉瘤的初期与长期结局
回顾性研究显示,低剖面编织支架Y型支架辅助弹簧圈栓塞治疗宽颈及复杂分叉部动脉瘤有效、相对安全且持久。
要点
- 术后即刻完全闭塞率72.5%,末次随访(平均24.8个月)升至85%。
- 随访期间仅1例动脉瘤充盈状态增加,且未需再治疗。
- 总体手术相关并发症率17.5%(含无症状),永久性病残率2.5%,无死亡。
核心结论
- 回顾性研究显示,低剖面编织支架Y型支架辅助弹簧圈栓塞治疗宽颈及复杂分叉部动脉瘤有效、相对安全且持久。
研究设计与样本
- 回顾性研究,纳入40例患者共40个颅内动脉瘤,采用低剖面编织支架行Y型支架辅助弹簧圈栓塞。
诊断标准与关键数值
- 术后即刻数字减影血管造影示动脉瘤完全闭塞72.5%。
- 末次随访血管造影示85%患者完全闭塞,平均血管造影随访时间24.8个月。
临床应用与阅片要点
- 术后即刻完全闭塞率72.5%,末次随访(平均24.8个月)完全闭塞率85%,随访期间仅1例动脉瘤充盈状态增加且未需再治疗。
- 总体手术相关并发症率17.5%(含无症状并发症),永久性病残1例(2.5%),无死亡。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
BACKGROUND AND PURPOSE: Coiling complex intracranial bifurcation aneurysms often necessitates the implantation of double stents in various configurations, such as Y-stent placement. Low-profile braided stents have been introduced recently to facilitate the endovascular treatment of wide-neck aneurysms. We aimed to investigate the feasibility, safety, efficacy, and durability of Y-stent-assisted coiling with double low-profile braided stents for the treatment of complex bifurcation aneurysms.
MATERIALS AND METHODS: A retrospective review was performed to identify patients who were treated using Y-stent-assisted coiling with low-profile braided stents. Technical success was assessed, as were initial and follow-up clinical and angiographic outcomes. Periprocedural and delayed complications were reviewed. Preprocedural and follow-up clinical statuses were assessed using the modified Rankin Scale.
RESULTS: Forty patients with 40 intracranial aneurysms were included in the study. Y-stent placement was successfully performed in all cases. Immediate postprocedural digital subtraction angiography images revealed total aneurysm occlusion in 72.5% of cases. The mean angiographic follow-up time was 24.8 months. The last follow-up angiograms showed complete occlusion in 85% of patients. During follow-up, only 1 patient showed an increase in the filling status of the aneurysm and that patient did not require retreatment. There was no mortality in this study. The overall procedure-related complication rate, including asymptomatic complications, was 17.5%. A permanent morbidity developed in 1 patient (2.5%).
CONCLUSIONS: The long-term angiographic and clinical outcomes of this retrospective study demonstrate that Y-stent-assisted coiling using low-profile braided stents is an effective, relatively safe, and durable endovascular treatment for wide-neck and complex bifurcation aneurysms.
引用
- Aydin K, Men S, Barburoglu M, et al. Initial and Long-Term Outcomes of Complex Bifurcation Aneurysms Treated by Y-Stent-Assisted Coiling with Low-Profile Braided Stents. AJNR Am J Neuroradiol. 2018. PMID: 30409852. doi:10.3174/ajnr.A5869
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。