脑部平扫T1加权图像信号强度增高的标准化评估:欧洲钆滞留评估联盟(GREC)工作组立场声明
该立场声明由欧洲钆滞留评估联盟工作组制定,评估已发表回顾性研究的方法学基础,并为未来研究定义质量标准,以指导科学界并帮助识别方法学可能有缺陷、结果可能误导的研究。声明指出,脑内钆依赖的T1w高信号取决于患者病史、所用GBCA类型(线性 vs 大环)及MR成像设置和协议。
要点
- 线性GBCA可致脑内T1w信号增高,首见于齿状核;大环GBCA未见信号增高。
- 信号强度差异并不明确代表钆滞留量,方法学错误可能导致错误结论。
- 脑内钆依赖T1w高信号取决于患者病史、GBCA类型及MR成像设置和协议。
核心结论
- 需为未来研究设计质量标准以标准化方法学,避免回顾性研究可能误导的结果。
研究设计与样本
- 欧洲钆滞留评估联盟(GREC)工作组立场声明,评估已发表回顾性研究的方法学基础并定义未来研究质量标准。
关键影像表现/征象
- 绝大多数研究显示线性GBCA在脑内引起信号强度增高,首先在齿状核,而大环GBCA未见信号强度增高。
局限性
- 信号强度差异并不明确代表钆滞留量,关于此发现的科学争论持续存在。
- 方法学错误可能产生有缺陷的结论。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
After the initial report in 2014 on T1-weighted (T1w) hyperintensity of deep brain nuclei following serial injections of linear gadolinium-based contrast agents (GBCAs), a multitude of studies on the potential of the marketed GBCAs to cause T1w hyperintensity in the brain have been published. The vast majority of these studies found a signal intensity (SI) increase for linear GBCAs in the brain-first and foremost in the dentate nucleus-while no SI increase was found for macrocyclic GBCAs. However, the scientific debate about this finding is kept alive by the fact that SI differences do not unequivocally represent the amount of gadolinium retained. Since the study design of the SI measurement in various brain structures is relatively simple, MRI studies investigating gadolinium-dependent T1w hyperintensity are currently conducted at multiple institutions worldwide. However, methodological mistakes may result in flawed conclusions. In this position statement, we assess the methodological basis of the published retrospective studies and define quality standards for future studies to give guidance to the scientific community and to help identify studies with potentially flawed methodology and misleading results. KEY POINTS: • A multitude of studies has been published on the potential of the marketed GBCAs to cause T1w hyperintensity in the brain. • The gadolinium-dependent T1w hyperintensity in the brain depends on patient's history, types of GBCAs used (i.e., linear vs. macrocyclic GBCAs) and MR imaging setup and protocols. • Quality standards for the design of future studies are needed to standardize methodology and avoid potentially misleading results from retrospective studies.
引用
- Quattrocchi CC, Ramalho J, van der Molen AJ, et al. Standardized assessment of the signal intensity increase on unenhanced T1-weighted images in the brain: the European Gadolinium Retention Evaluation Consortium (GREC) Task Force position statement. Eur Radiol. 2018. PMID: 30413951. doi:10.1007/s00330-018-5803-6
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。