文献速递外周血管心血管CT

低千伏CT血管成像中 revisiting 滤波反投影:锐利滤波核可改善Adamkiewicz动脉的显示

Filtered back projection revisited in low-kilovolt computed tomography angiography: sharp filter kernel enhances visualization of the artery of Adamkiewicz.
PubMed 文献 · Neuroradiology · 2018-11-21

该回顾性研究纳入40例在主动脉修复术前接受80 kV CT血管成像的患者,比较锐利与平滑滤波核重建的脊髓CTA图像质量;锐利滤波核的脊髓动脉CT值和对比噪声比均显著更高(P<.001),Adamkiewicz动脉与主动脉连续性的主观评分也显著更高(P<.001)。

要点

  • 80 kV CTA重建时选用锐利滤波核可提高脊髓动脉CT值与对比噪声比。
  • 锐利滤波核较平滑滤波核显著改善Adamkiewicz动脉与主动脉连续性的主观评分。
  • 观察Adamkiewicz动脉时应关注其与主动脉连接处(尤其椎弓根周围)的连续性。

核心结论

  • 锐利滤波核显著改善了低管电压CTA评估Adamkiewicz动脉的图像质量,可在评估该动脉时提供高置信度。

研究设计与样本

  • 回顾性研究,连续纳入40例在主动脉修复术前接受80 kV CTA检查的患者,比较锐利与平滑滤波核重建的脊髓CTA图像质量。

关键影像表现/征象

  • 锐利滤波核重建的脊髓动脉CT值显著高于平滑滤波核(P<.001)。
  • 锐利滤波核重建的脊髓动脉对比噪声比显著高于平滑滤波核(P<.001)。
  • 锐利滤波核重建的Adamkiewicz动脉与主动脉连续性3分法评分显著高于平滑滤波核(P<.001)。

诊断标准与关键数值

  • Adamkiewicz动脉与主动脉连续性采用3分法评估:2分为绝对,0分为不可检测。
  • 脊髓动脉CT值与对比噪声比在锐利滤波核与平滑滤波核之间差异均有统计学意义(P<.001)。
  • Adamkiewicz动脉与主动脉连续性评分在锐利滤波核与平滑滤波核之间差异有统计学意义(P<.001)。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: The reliability of assessment of the artery of Adamkiewicz before the aortic repair is highly dependent on the display of the continuity of this artery with the aorta, mainly around the vertebral pedicle, by computed tomography angiography (CTA). We hypothesized that the sharp filter kernel can improve visualization of this continuity of the vessel structure because of its edge enhancement and high-spatial resolution. This study was performed to compare the subjective and objective image quality of spinal CTA reconstructed with sharp and smooth filter kernels.

METHODS: We retrospectively reviewed 40 consecutive patients who had undergone 80-kV CTA to detect the artery of Adamkiewicz before aortic repair. We measured the CT number and the contrast-to-noise ratio of the anterior spinal artery to the spinal cord. Furthermore, the continuity of the artery of Adamkiewicz was evaluated using a 3-point scale (2 points, absolute; 0 points, undetectable).

RESULTS: CTA with the sharp filter kernel showed a significantly higher CT number and contrast-to-noise ratio of the spinal artery than did CTA with the smooth filter kernel (P < .001 for both). Moreover, the sharp filter kernel showed a significantly higher continuity of the artery of Adamkiewicz with the aorta than did the smooth filter kernel (P < .001).

CONCLUSIONS: The sharp filter kernel significantly improved the image quality in low-tube-voltage CTA for the assessment of the artery of Adamkiewicz. Thus, CTA with the sharp filter kernel can generate a high-confidence level in the evaluation of the artery of Adamkiewicz.

来源:Neuroradiology,查看原文。版权归原作者所有。

引用

  1. Nishii T, Kotoku A, Hori Y, et al. Filtered back projection revisited in low-kilovolt computed tomography angiography: sharp filter kernel enhances visualization of the artery of Adamkiewicz. Neuroradiology. 2018. PMID: 30465057. doi:10.1007/s00234-018-2136-8

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。