文献速递神经MR

基于多参数磁共振成像的机器学习区分多形性胶质母细胞瘤与原发性中枢神经系统淋巴瘤

Machine learning based on multi-parametric magnetic resonance imaging to differentiate glioblastoma multiforme from primary cerebral nervous system lymphoma.
PubMed 文献 · Eur J Radiol · 2018-09-14

回顾性纳入70例在3T行脑MRI增强的肿瘤患者,其中胶质母细胞瘤45例、原发性中枢神经系统淋巴瘤25例,基于T2WI、ADC图、rCBV图及CE-T1WI的12个直方图与纹理参数建模。单因素logistic回归中rCBV标准差AUC最高(0.86),XGBoost模型AUC为0.98,显著高于两位放射科医师(0.84与0.79,P均<0.01)。

要点

  • rCBV标准差在单参数中鉴别效能最高,AUC为0.86。
  • XGBoost模型AUC 0.98,高于两位放射科医师的0.84与0.79(P均<0.01)。
  • 基于多参数MRI直方图与纹理特征的机器学习优于传统截断值方法及放射科医师判断。

核心结论

  • 基于多参数MRI直方图与纹理特征的机器学习鉴别GBM与PCNSL的效能优于传统截断值方法和两位认证放射科医师。

研究设计与样本

  • 回顾性研究,纳入70例在3T行脑MRI增强且诊断为GBM(n=45)或PCNSL(n=25)的患者,评估T2WI、ADC图、rCBV图及CE-T1WI上的12个直方图与纹理参数。

诊断标准与关键数值

  • 单因素logistic回归中rCBV标准差AUC最高为0.86,其次为rCBV均值0.83、CE-T1WI偏度0.78、CE-T1WI均值0.78、rCBV最大值0.77。

临床应用与阅片要点

  • XGBoost模型AUC为0.98,显著高于两位放射科医师的0.84(P<0.01)与0.79(P<0.01);原文结论为机器学习效能优于传统截断值方法与认证放射科医师。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: To evaluate the performance of a machine learning method based on texture features in multi-parametric magnetic resonance imaging (MRI) to differentiate a glioblastoma multiforme (GBM) from a primary cerebral nervous system lymphoma (PCNSL).

MATERIALS AND METHODS: We included 70 patients who underwent contrast enhanced brain MRI at 3 T with brain tumors diagnosed as GBM (n = 45) and PCNSL (n = 25) in this retrospective study. Twelve histograms and texture parameters were assessed on T2-weighted images (T2WIs), apparent diffusion coefficient maps, relative cerebral blood volume (rCBV) map, and contrast-enhanced T1-weighted images (CE-T1WIs). A prediction model was developed using a machine learning method (univariate logistic regression and multivariate eXtreme gradient boosting-XGBoost) and the area under the receiver operating characteristic curve of this model was calculated via 10-fold cross validation. In addition, the performance of the machine learning method was compared with the judgments of two board certified radiologists.

RESULTS: With the univariate logistic regression model, the standard deviation of rCBV offered the highest AUC (0.86), followed by mean value of rCBV (0.83), skewness of CE-T1WI (0.78), mean value of CET1 (0.78), and max value of rCBV (0.77). The AUC of the XGBoost was significantly higher than the two radiologists (0.98 vs. 0.84; p < 0.01 and 0.98 vs. 0.79; p < 0.01, respectively).

CONCLUSION: The performance of machine learning based on histogram and texture features in multi-parametric MRI was superior to that of conventional cut-off method and the board certified radiologists to differentiate a GBM from a PCNSL.

来源:Eur J Radiol,查看原文。版权归原作者所有。

引用

  1. Nakagawa M, Nakaura T, Namimoto T, et al. Machine learning based on multi-parametric magnetic resonance imaging to differentiate glioblastoma multiforme from primary cerebral nervous system lymphoma. Eur J Radiol. 2018. PMID: 30396648. doi:10.1016/j.ejrad.2018.09.017

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。