脑萎缩与临床常规随访的多发性硬化患者残疾进展相关

Brain Atrophy Is Associated with Disability Progression in Patients with MS followed in a Clinical Routine.
PubMed 文献 · AJNR Am J Neuroradiol · 2018-11-22

回顾性纳入1815例受试者(1514例多发性硬化、137例临床孤立综合征、164例健康对照)共11794次脑MRI,用SIENA/SIENAX测量全脑体积变化、NeuroSTREAM测量侧脑室体积变化;三种脑体积指标均能区分多发性硬化与健康人,且与残疾进展相关,其中侧脑室体积评估最可行。

要点

  • 侧脑室体积变化评估失败率仅3.3%,是全脑体积指标中最可行的临床常规脑萎缩测量方法。
  • 多发性硬化患者残疾进展与全脑体积年化下降21.9%、侧脑室体积年化增加33%相关。
  • 全脑体积变化失败率较高:百分比脑体积变化36.7%、百分比标准化脑体积变化19.2%。

核心结论

  • 所有脑体积指标均能区分多发性硬化患者与健康个体,并与残疾进展相关,但侧脑室体积评估最可行。

研究设计与样本

  • 回顾性收集1815例受试者(1514例多发性硬化、137例临床孤立综合征、164例健康个体)共11794次脑MRI,其中8423次在3T、3371次在1.5T扫描仪完成,所有时间点均行3D T1WI和T2-FLAIR检查。

关键影像表现/征象

  • 全脑体积变化通过SIENA/SIENAX在3D T1WI上测量百分比脑体积变化和百分比标准化脑体积变化。
  • 侧脑室体积变化通过NeuroSTREAM在T2-FLAIR上测量百分比侧脑室体积变化。

诊断标准与关键数值

  • 百分比脑体积变化失败率36.7%,百分比标准化脑体积变化失败率19.2%,百分比侧脑室体积变化失败率3.3%,原因为扫描方案变更、扫描质量差、伪影和解剖变异。
  • 多发性硬化患者与健康个体间年化脑体积变化有显著差异:百分比脑体积变化P < .001、百分比标准化脑体积变化P = .002、百分比侧脑室体积变化P = .01。
  • 多发性硬化患者中,混合效应模型分析显示残疾进展与百分比脑体积变化年化下降21.9%(P < .001)、标准化脑体积年化下降(P = .002)及侧脑室体积增加33%(P = .004)相关。

临床应用与阅片要点

  • 在临床常规随访中,侧脑室体积变化评估因失败率最低而最具可行性。
  • 全脑体积测量失败率较高,判读时需考虑扫描方案变更、图像质量、伪影和解剖变异的影响。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

BACKGROUND AND PURPOSE: The assessment of brain atrophy in a clinical routine is not performed routinely in multiple sclerosis. Our aim was to determine the feasibility of brain atrophy measurement and its association with disability progression in patients with MS followed in a clinical routine for 5 years.

MATERIALS AND METHODS: A total of 1815 subjects, 1514 with MS and 137 with clinically isolated syndrome and 164 healthy individuals, were collected retrospectively. Of 11,794 MR imaging brain scans included in the analysis, 8423 MRIs were performed on a 3T, and 3371 MRIs, on a 1.5T scanner. All patients underwent 3D T1WI and T2-FLAIR examinations at all time points of the study. Whole-brain volume changes were measured by percentage brain volume change/normalized brain volume change using SIENA/SIENAX on 3D T1WI and percentage lateral ventricle volume change using NeuroSTREAM on T2-FLAIR.

RESULTS: Percentage brain volume change failed in 36.7% of the subjects; percentage normalized brain volume change, in 19.2%; and percentage lateral ventricle volume change, in 3.3% because of protocol changes, poor scan quality, artifacts, and anatomic variations. Annualized brain volume changes were significantly different between those with MS and healthy individuals for percentage brain volume change (P < .001), percentage normalized brain volume change (P = .002), and percentage lateral ventricle volume change (P = .01). In patients with MS, mixed-effects model analysis showed that disability progression was associated with a 21.9% annualized decrease in percentage brain volume change (P < .001) and normalized brain volume (P = .002) and a 33% increase in lateral ventricle volume (P = .004).

CONCLUSIONS: All brain volume measures differentiated MS and healthy individuals and were associated with disability progression, but the lateral ventricle volume assessment was the most feasible.