文献速递神经MR

过估比与双层磁敏感血管征作为心源性栓塞性卒中及发病至MRI时间影像生物标志物的验证

Validation of overestimation ratio and TL-SVS as imaging biomarker of cardioembolic stroke and time from onset to MRI.
PubMed 文献 · Eur Radiol · 2018-11-12

在THRACE试验中,评估双层磁敏感血管征(TL-SVS)和过估比(overR)与心源性栓塞性卒中(CES)及发病至MRI时间的关联。258例患者中,overR四分位数仅与CES相关(OR 1.83),发病至MRI每增加60分钟与TL-SVS相关(OR 1.72),MRI技术参数与两者均无统计学关联。

要点

  • 过估比(overR)升高与心源性栓塞性卒中独立相关,不受GRE序列参数影响。
  • TL-SVS与发病至MRI时间延长独立相关,每增加60分钟OR为1.72。
  • MRI技术参数(层间隔、层厚、回波时间、翻转角、体素大小、场强)与overR及TL-SVS均无统计学关联。

核心结论

  • 独立于GRE序列参数,过估比升高与心源性栓塞性卒中相关,而TL-SVS与发病至MRI时间延长独立相关。

研究设计与样本

  • THRACE试验的事后分析,纳入258例有治疗前脑梯度回波(GRE)序列和病因学检查的患者,其中102例经3 Tesla MRI检查,156例经1.5 Tesla MRI检查;由两名读者评估TL-SVS和overR。

关键影像表现/征象

  • TL-SVS定义为磁敏感血管征中心呈线性低信号核心,周围环绕较高信号。
  • overR定义为磁敏感血管征宽度除以动脉宽度。

诊断标准与关键数值

  • overR中位值为1.59(四分位距1.30至1.86)。
  • TL-SVS存在于101例患者中(39.2%,95%CI 33.1至45.1%)。
  • 多因素分析中,仅CES与overR四分位数相关(OR 1.83,95%CI 1.11至2.99)。
  • 发病至MRI时间每增加60分钟与TL-SVS相关(OR 1.72,95%CI 1.10至2.67)。
  • overR四分位数和TL-SVS的读者内和读者间一致性为良好至优秀。

临床应用与阅片要点

  • 过估比(overR)和TL-SVS可作为影像生物标志物,用于预测卒中病因以调整二级预防。
  • TL-SVS的出现需结合发病至MRI时间解读,时间越长TL-SVS越可能出现。
  • MRI技术参数(层间隔、层厚、回波时间、翻转角、体素大小、场强)与overR及TL-SVS均无统计学关联。

局限性

  • 原文未报告局限性

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: We aimed to determine in the "THRACE" trial, the clinical and MRI technical parameters associated with the two-layered susceptibility vessel sign (TL-SVS) and the overestimation ratio (overR).

MATERIALS AND METHODS: Patients with pre-treatment brain gradient echo (GRE) sequence and an etiological work-up were identified. Two readers reviewed TL-SVS, i.e., a SVS with a linear low-intense signal core surrounded by a higher intensity and measured the overR as the width of SVS divided by the width of the artery. Binomial and ordinal logistic regression respectively tested the association between TL-SVS and quartiles of overR with patient characteristics, cardioembolic stroke (CES), time from onset to imaging, and GRE sequence parameters (inter slice gap, slice thickness, echo time, flip angle, voxel size, and field strength).

RESULTS: Among 258 included patients, 102 patients were examined by 3 Tesla MRI and 156 by 1.5 Tesla MRI. Intra- and inter-reader agreements for quartiles of overR and TL-SVS were good to excellent. The median overR was 1.59 (IQR, 1.30 to 1.86). TL-SVS was present in 101 patients (39.2%, 95%CI, 33.1 to 45.1%). In multivariate analysis, only CES was associated with overR quartiles (OR, 1.83; 95%CI, 1.11 to 2.99), and every 60 min increase from onset to MRI time was associated with TL-SVS (OR, 1.72; 95%CI, 1.10 to 2.67). MRI technical parameters were statistically associated with neither overR nor TL-SVS.

CONCLUSION: Independent of GRE sequence parameters, an increased overR was associated to CES, while the TL-SVS is independently related to a longer time from onset to MRI.

KEY POINTS: • An imaging biomarker would be useful to predict the etiology of stroke in order to adapt secondary prevention of stroke. • The two-layered susceptibility vessel sign and the overestimation ratio are paramagnetic effect derived markers that vary according to the MRI machines and sequence parameters. • Independent of sequence parameters, an increased overestimation ratio was associated to cardioembolic stroke, while the two-layered susceptibility vessel sign is independently related to a longer time from onset to MRI.

来源:Eur Radiol,查看原文。版权归原作者所有。

引用

  1. Bourcier R, Legrand L, Soize S, et al. Validation of overestimation ratio and TL-SVS as imaging biomarker of cardioembolic stroke and time from onset to MRI. Eur Radiol. 2018. PMID: 30421018. doi:10.1007/s00330-018-5835-y

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。