MR成像鉴别急性缺血性卒中血管内取栓术后对比剂染色与出血转化:体模与患者研究
本研究通过体模与初步回顾性患者研究,评估介入术后即刻DWI方案(含B0与梯度回波序列)鉴别对比剂染色与出血转化的价值。体模中碘对比剂与盐水混合信号下降轻微,与动脉血混合则在T2WI和梯度回波呈暗信号。患者研究中所有出血转化在B0-DWI和梯度回波上呈暗/低信号(低于灰质),而对比剂染色均无此表现。
要点
- 介入术后即刻DWI含梯度回波序列,出血转化在B0-DWI和梯度回波上呈暗或低信号(低于灰质),对比剂染色则无此表现。
- 体模中碘对比剂与盐水混合信号下降轻微,与动脉血混合则在T2WI和梯度回波呈暗信号。
- 作者认为该方案可能有助于鉴别对比剂染色与出血转化,并可能加快术后治疗策略的制定。
核心结论
- 根据初步结果,包含梯度回波序列的介入术后即刻DWI方案可能鉴别对比剂染色与出血转化,并可能加快术后内科治疗策略的建立。
研究设计与样本
- 体模研究联合初步回顾性患者研究,在3T MR上比较碘对比剂与盐水混合及与动脉血混合的体模在T1WI、T2WI和梯度回波序列上的信号强度;纳入17例因急性缺血性卒中行机械取栓、术后即刻(<24小时)平扫CT出现新发高密度病灶的患者(出血转化8例、对比剂染色9例;男8例、女9例;平均年龄72.00±10.91岁,范围52-90岁),比较其介入术后即刻DWI。
关键影像表现/征象
- 体模中碘对比剂与盐水混合信号下降轻微,与动脉血混合则在T2WI和梯度回波序列呈暗信号。
- 患者中所有出血转化在B0-DWI和梯度回波图像上呈暗或低信号(低于灰质),信号类似血管。
- 患者中无一例对比剂染色在B0-DWI和梯度回波图像上呈暗或低信号(低于灰质)。
临床应用与阅片要点
- 作者认为,介入术后即刻DWI方案包含梯度回波序列,可能用于鉴别对比剂染色与出血转化。
- 作者认为,该方案可能加快术后内科治疗策略的建立。
局限性
- 原文结论称其为初步结果,并使用了「might be differentiated」「might be possible」等限定表述。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
BACKGROUND AND PURPOSE: Early differentiation of contrast staining from hemorrhagic transformation in patients with acute ischemic stroke who have undergone endovascular treatment is critical in preventing the delayed administration of antiplatelet agents. We aimed to demonstrate the usefulness of an immediate postinterventional DWI protocol including B0 and gradient recalled-echo sequences to discriminate those 2 conditions through phantom and preliminary retrospective patient studies.
MATERIALS AND METHODS: On 3T MR imaging, the signal intensities of the phantom models consisting of iodinated contrast agents diluted with normal saline and arterial blood were compared using T1WI, T2WI, and gradient recalled-echo sequences. A total 17 patients (8 with hemorrhagic transformation and 9 with contrast staining; 8 men and 9 women; mean age, 72.00 ± 10.91 years; range, 52-90 years) who underwent mechanical thrombectomy for acute ischemic stroke and showed newly appearing hyperdense lesions on immediate (<24 hours) postinterventional nonenhanced CT scans were included in this study. Immediate postinterventional DWI of patients were compared.
RESULTS: In the phantom study, iodinated contrast agents diluted with normal saline showed minimal signal drop, while those diluted with arterial blood demonstrated dark signal intensity in the T2WI and gradient recalled-echo sequences. In the patient study, all hemorrhagic transformations and none of the contrast staining demonstrated dark or low signal (<gray matter) intensities similar to those of the vessel in the B0-DWI and gradient recalled-echo images.
CONCLUSIONS: According to our preliminary results, contrast staining might be differentiated from hemorrhagic transformation using an immediate postinterventional DWI protocol including gradient recalled-echo sequences. It might be possible to expedite establishment of postinterventional medical treatment strategy.
引用
- You SH, Kim B, Kim BK, et al. MR Imaging for Differentiating Contrast Staining from Hemorrhagic Transformation after Endovascular Thrombectomy in Acute Ischemic Stroke: Phantom and Patient Study. AJNR Am J Neuroradiol. 2018. PMID: 30385471. doi:10.3174/ajnr.A5848
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。