单侧腰椎间盘突出症患者多裂肌的剪切波弹性成像研究
本研究纳入33例经MRI诊断的单侧椎间盘亚关节型突出伴神经根压迫患者,用剪切波弹性成像(SWE)测量多裂肌硬度。患侧多裂肌硬度(观察者1为14.08±3.57 kPa,观察者2为13.70±4.05 kPa)显著低于健侧(观察者1为18.81±3.95 kPa,观察者2为18.28±4.12 kPa,P<.001)。多裂肌硬度与症状持续时间及神经压迫严重程度呈中度负相关(观察者1 r=-0.535,观察者2 r=-0.458,P<.001)。
要点
- 单侧腰椎间盘突出伴神经根压迫患者患侧多裂肌SWE硬度值显著低于健侧
- 多裂肌硬度与症状持续时间及神经压迫严重程度呈中度负相关
- SWE检查以椎骨棘突为体表标志,在突出部位稍下方进行测量
核心结论
- 腰椎间盘突出症同侧多裂肌SWE硬度值降低,且硬度值与病程及神经压迫严重程度呈负相关;进一步研究可能揭示多裂肌SWE在判断临床结局和评估治疗效果中的潜在作用。
研究设计与样本
- 研究纳入33例经MRI诊断的单侧椎间盘亚关节型突出(L3-L4、L4-L5、L5-S1)致神经根压迫患者,由两名观察者分别行多裂肌SWE检查,比较患侧与健侧硬度,并计算硬度与症状持续时间及神经压迫严重程度的相关性。
诊断标准与关键数值
- 患侧多裂肌平均硬度:观察者1为14.08±3.57 kPa,观察者2为13.70±4.05 kPa;健侧:观察者1为18.81±3.95 kPa,观察者2为18.28±4.12 kPa;患侧显著低于健侧(P<.001)。硬度与症状持续时间及神经压迫严重程度的相关性:观察者1 r=-0.535,观察者2 r=-0.458(P<.001)。
临床应用与阅片要点
- 作者认为,进一步研究可能揭示多裂肌SWE在判断腰椎间盘突出症患者临床结局和评估治疗效果中的潜在作用。
局限性
- 原文在结论中提出需进一步研究(Further studies might reveal the potential role of SWE of the multifidus muscle in determining clinical outcomes and assessing effectiveness treatment in patients with LDH)。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: To assess lumbar multifidus muscle stiffness in patients with unilateral lumbar disk herniation (LDH) causing nerve root compression using shear wave elastography (SWE).
METHODS: Thirty-three patients with unilateral subarticular LDH (L3-L4, L4-L5, and L5-S1) causing nerve root compression, diagnosed by magnetic resonance imaging, were enrolled in the study. Exclusion criteria were bilateral or multilevel LDH confirmed on magnetic resonance imaging, bilateral leg symptoms, and patients with a history of any spinal operation, malignancy, trauma, infection, spondylolisthesis, severe lateral recess stenosis, spinal canal stenosis, and substantial comorbidities. Two observers separately evaluated the multifidus muscle using SWE. Shear wave elastographic examinations of the muscle were performed slightly below the herniation using the spinous process of the vertebra as a landmark. The stiffness of the muscle between affected and normal sides was compared. Moreover, the correlation between the stiffness and duration of the symptoms and the correlation between the stiffness and severity of the nerve compression were also calculated.
RESULTS: The mean stiffness values of the multifidus muscle on the affected side (mean ± SD: observer 1, 14.08 ± 3.57 kPa; observer 2, 13.70 ± 4.05 kPa) were significantly lower compared to the contralateral side (observer 1, 18.81 ± 3.95 kPa; observer 2, 18.28 ± 4.12 kPa; P < .001). The muscle stiffness had a moderate negative correlation with the duration of the symptoms and the severity of the nerve compression (observer 1, r = -0.535; observer 2, r = -0.458; P < .001).
CONCLUSIONS: The multifidus muscle on the ipsilateral side of the LDH showed reduced stiffness values, and stiffness values were negatively correlated with the disease duration and severity of the nerve compression. Further studies might reveal the potential role of SWE of the multifidus muscle in determining clinical outcomes and assessing effectiveness treatment in patients with LDH.
引用
- Alis D, Durmaz ESM, Alis C, et al. Shear Wave Elastography of the Lumbar Multifidus Muscle in Patients With Unilateral Lumbar Disk Herniation. J Ultrasound Med. 2018. PMID: 30426520. doi:10.1002/jum.14854
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。