文献速递外周血管神经技术与安全US

颈动脉狭窄患者的在体脉搏波成像研究

Pulse Wave Imaging in Carotid Artery Stenosis Human Patients in Vivo.
PubMed 文献 · Ultrasound Med Biol · 2018-11-12

本研究对111例中重度颈动脉狭窄患者(n=11,N=13个斑块)及5名健康志愿者行脉搏波成像,采用常规与高帧率平面波射频序列生成脉搏波速度图及斑块内累积位移与应变图。定性观察到斑块周围/内部波汇聚、脉搏波速度升高和累积位移减低;定量显示中度和重度钙化斑块累积应变显著低于正常对照(p<0.01),重度钙化斑块区域顺应性亦显著低于正常对照(p<0.01)。

要点

  • 斑块周围/内部可见波汇聚、脉搏波速度升高和累积位移减低,可能作为斑块特征标志物。
  • 斑块内脉搏波速度与累积应变图有助区分钙化(稳定)与脂质(易损)斑块成分。
  • 中度和重度钙化斑块累积应变显著低于正常对照(p<0.01),重度钙化斑块区域顺应性亦显著低于正常对照(p<0.01)。

核心结论

  • 这项先导研究提示,脉搏波成像联合应变成像有潜力区分不同硬度、位置和成分的斑块,可能为弥补现有卒中风险评估方法的局限提供有价值的信息。

研究设计与样本

  • 先导研究,纳入111例(n=11,N=13个斑块)中度(>50%)至重度(>80%)颈动脉狭窄患者,另以5名健康志愿者(n=5,N=20次测量)为对照组;采用常规与高帧率平面波射频成像序列,生成狭窄颈动脉段单一深度脉搏波速度分段图及斑块内多深度脉搏波速度图,并计算斑块内累积位移与应变图,基于脉搏波速度和直径用Bramwell-Hill方程估算斑块区域顺应性。

关键影像表现/征象

  • 定性观察到斑块周围和/或内部区域波汇聚、脉搏波速度升高和累积位移减低,可能作为斑块特征标志物。
  • 斑块内成像显示有潜力捕捉钙化包涵体之间的波反射,并基于斑块内脉搏波速度和累积应变区分稳定(钙化)与易损(脂质)斑块成分。

诊断标准与关键数值

  • 单因素方差分析显示,中度和重度钙化斑块的脉搏波诱导累积应变显著低于正常对照(p<0.01)。
  • 重度钙化斑块区域顺应性显著低于正常对照(p<0.01)。

局限性

  • 原文称本研究为先导研究(pilot study)。
  • 原文结论指出这类发现可能为弥补现有卒中风险评估方法的局限提供有价值的信息。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

Carotid stenosis involves narrowing of the lumen in the carotid artery potentially leading to a stroke, which is the third leading cause of death in the United States. Several recent investigations have found that plaque structure and composition may represent a more direct biomarker of plaque rupture risk compared with the degree of stenosis. In this study, pulse wave imaging was applied in 111 (n = 11, N = 13 plaques) patients diagnosed with moderate (>50%) to severe (>80%) carotid artery stenosis to investigate the feasibility of characterizing plaque properties based on the pulse wave-induced arterial wall dynamics captured by pulse wave imaging. Five (n = 5 patients, N = 20 measurements) healthy volunteers were also imaged as a control group. Both conventional and high-frame-rate plane wave radiofrequency imaging sequences were used to generate piecewise maps of the pulse wave velocity (PWV) at a single depth along stenotic carotid segments, as well as intra-plaque PWV mapping at multiple depths. Intra-plaque cumulative displacement and strain maps were also calculated for each plaque region. The Bramwell-Hill equation was used to estimate the compliance of the plaque regions based on the PWV and diameter. Qualitatively, wave convergence, elevated PWV and decreased cumulative displacement around and/or within regions of atherosclerotic plaque were observed and may serve as biomarkers for plaque characterization. Intra-plaque mapping revealed the potential to capture wave reflections between calcified inclusions and differentiate stable (i.e., calcified) from vulnerable (i.e., lipid) plaque components based on the intra-plaque PWV and cumulative strain. Quantitatively, one-way analysis of variance indicated that the pulse wave-induced cumulative strain was significantly lower (p < 0.01) in the moderately and severely calcified plaques compared with the normal controls. As expected, compliance was also significantly lower in the severely calcified plaques regions compared with the normal controls (p < 0.01). The results from this pilot study indicated the potential of pulse wave imaging coupled with strain imaging to differentiate plaques of varying stiffness, location and composition. Such findings may serve as valuable information to compensate for the limitations of currently used methods for the assessment of stroke risk.

来源:Ultrasound Med Biol,查看原文。版权归原作者所有。

引用

  1. Li RX, Apostolakis IZ, Kemper P, et al. Pulse Wave Imaging in Carotid Artery Stenosis Human Patients in Vivo. Ultrasound Med Biol. 2018. PMID: 30442386. doi:10.1016/j.ultrasmedbio.2018.07.013

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。