文献速递神经技术与安全MR

动态对比增强磁共振成像评估C6胶质瘤大鼠模型肿瘤乏氧

Evaluation of Tumor Hypoxia in C6 Glioma Rat Model With Dynamic Contrast-Enhanced Magnetic Resonance Imaging.
PubMed 文献 · Acad Radiol · 2018-10-30

研究纳入30只雄性Sprague-Dawley大鼠建立C6脑胶质瘤模型,于移植后14、21、28天行DCE-MRI扫描并计算Ktrans、Ve、Kep、Vp,每次扫描后随机选10只行HIF-1α、PCNA、CD34免疫组化染色,分析定量参数与免疫组化评分的相关性。结果显示Ktrans、Ve、Kep在三个时间点间差异有统计学意义,Vp无显著差异(P=0.073),Ktrans与HIF-1α评分在14天和21天呈显著负相关,DCE-MRI可能可用于无创评估胶质瘤模型乏氧状态。

要点

  • Ktrans、Ve、Kep在移植后14、21、28天三个时间点间差异有统计学意义。
  • Vp在三个时间点间无显著差异(P=0.073)。
  • Ktrans与HIF-1α评分在14天和21天呈显著负相关,同时Ktrans与CD34呈正相关。

核心结论

  • DCE-MRI可能是一种无创评估胶质瘤模型乏氧状态的有用方法。

研究设计与样本

  • 动物实验研究,30只雄性Sprague-Dawley大鼠接种建立C6脑胶质瘤模型,于移植后14、21、28天行DCE-MRI扫描,计算Ktrans、Ve、Kep、Vp定量参数,每次扫描后随机选10只大鼠行HIF-1α、PCNA、CD34免疫组化染色,分析定量参数与免疫组化评分的相关性。

诊断标准与关键数值

  • Ktrans在14、21、28天分别为0.03 ± 0.009 min-1、0.084 ± 0.010 min-1、0.050 ± 0.016 min-1,三个时间点间差异有统计学意义。
  • Ve在14、21、28天分别为0.17 ± 0.070、0.46 ± 0.159、0.51 ± 0.193,三个时间点间差异有统计学意义。
  • Kep在14、21、28天分别为0.18 ± 0.070%、0.220 ± 0.049%、0.06 ± 0.035%,三个时间点间差异有统计学意义。
  • Vp在14、21、28天分别为0.09 ± 0.040%、0.120 ± 0.034%、0.06 ± 0.010%,三个时间点间无显著差异(P = 0.073)。
  • Ktrans在14天和21天与HIF-1α评分呈显著负相关,且与CD34呈正相关;Ve在14天和21天与HIF-1α评分呈负相关,21天与PCNA呈负相关;Kep在21天与HIF-1α评分呈负相关、与MVD呈正相关。

临床应用与阅片要点

  • 作者认为DCE-MRI可能可用于无创评估胶质瘤模型乏氧状态。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

RATIONALE AND OBJECTIVES: To investigate the feasibility of determining quantitative parameters for evaluating tumor hypoxia in the C6 glioma model by dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI).

MATERIALS AND METHODS: Thirty male Sprague-Dawley rats were inoculated to establish C6 brain glioma models. DCE-MRI scans were performed 14, 21, and 28 days after transplantation. Quantitative parameters comprising Ktrans, Ve, Kep, and Vp were calculated and analyzed. At the end of each scan, 10 rats were randomly selected for immunohistochemical (IHC) staining of hypoxia-inducible factor-17αl (HIF-1α), proliferating cell nuclear antigen (PCNA), and CD34. Correlations between quantitative parameters and IHC scores were analyzed.

RESULTS: The tumor volumes increased with time. The Ktrans values on days 14, 21, and 28 were 0.03 ± 0.009 min-1, 0.084 ± 0.010 min-1, and 0.050 ± 0.016 min-1, while the Ve values were 0.17 ± 0.070, 0.46 ± 0.159, and 0.51 ± 0.193, the Kep values were 0.18 ± 0.070%, 0.220 ± 0.049%, and 0.06 ± 0.035%, and these three parameters all differed significantly among the three time points. The Vp values on days 14, 21, and 28 were 0.09 ± 0.040%, 0.120 ± 0.034%, and 0.06 ± 0.010%, but the values did not differ among the three time points (P = 0.073). Ktrans had significant negative correlations with the HIF-1α scores on days 14 and 21 when there was also a positive correlation between Ktrans and CD34. Ve had negative correlations with the HIF-1α score on days 14 and 21, and there was a negative correlation between Ve and PCNA on day 21. Kep had a negative correlation with the HIF-1α score and a positive correlation with MVD on day 21.

CONCLUSIONS: DCE-MRI may be a useful method for the noninvasive evaluation of the hypoxia status in a glioma model.

来源:Acad Radiol,查看原文。版权归原作者所有。

引用

  1. Hou W, Xue Y, Tang W, et al. Evaluation of Tumor Hypoxia in C6 Glioma Rat Model With Dynamic Contrast-Enhanced Magnetic Resonance Imaging. Acad Radiol. 2018. PMID: 30385206. doi:10.1016/j.acra.2018.09.011