文献速递神经MR

基于T1-MPRAGE与T2-FLAIR的脑皮质及皮质下区域分割——一项MRI评估研究

T1-MPRAGE and T2-FLAIR segmentation of cortical and subcortical brain regions-an MRI evaluation study.
PubMed 文献 · Neuroradiology · 2018-11-06

本研究在3T MR上采集30名健康受试者的3D FLAIR与3D T1加权序列,采用基于形变配准的自动分割方法对全脑灰质、白质及116个图谱区域进行体积测量,并比较两种序列的分割结果。结果显示,FLAIR与T1分割在多数皮质结构上相关性良好(平均r=0.76),但丘脑(r=0.30)、基底节(平均r=0.59)、中央区(平均r=0.58)等区域相关性较弱;FLAIR分割低估中央区体积,且白质分割中高信号区常被误分类为灰质。

要点

  • FLAIR与T1分割在多数皮质灰质结构上相关性良好,平均r=0.76。
  • 丘脑(r=0.30)、基底节(平均r=0.59)、中央区(平均r=0.58)等区域FLAIR与T1分割相关性较弱。
  • FLAIR白质分割中高信号区常被误分类为灰质,阅片时需注意。

核心结论

  • 基于形变配准的FLAIR分割在多数皮质灰质结构上可获得与T1分割相当的结果,并可能对皮质下灰质结构提供解剖上更一致的分割;但部分皮质区域(尤其是中央区)及全脑白质在FLAIR分割中似乎被低估。

研究设计与样本

  • 研究纳入30名健康受试者(平均年龄29.9±8.3岁,8名女性),在同一台3T MR扫描仪上采集3D FLAIR与3D T1加权序列,采用基于形变配准的自动分割方法对全脑灰质、白质及116个图谱区域进行体积测量,并以Pearson相关系数比较两种序列的分割结果。

关键影像表现/征象

  • FLAIR分割中高信号强度的白质区域常被误分类为灰质。
  • FLAIR分割对中央区体积较T1分割低估。
  • 视觉审查显示FLAIR分割在枕叶及皮质下结构上与手动分割的解剖一致性优于T1。

诊断标准与关键数值

  • FLAIR与T1分割在全部皮质结构上的平均相关系数r=0.76。
  • 枕叶r=0.77,中央区平均r=0.58,基底节平均r=0.59,丘脑r=0.30,小脑r=0.73。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: Development of a warp-based automated brain segmentation approach of 3D fluid-attenuated inversion recovery (FLAIR) images and comparison to 3D T1-based segmentation.

METHODS: 3D FLAIR and 3D T1-weighted sequences of 30 healthy subjects (mean age 29.9 ± 8.3 years, 8 female) were acquired on the same 3T MR scanner. Warp-based segmentation was applied for volumetry of total gray matter (GM), white matter (WM), and 116 atlas regions. Segmentation results of both sequences were compared using Pearson correlation (r).

RESULTS: Correlation of GM segmentation results based on FLAIR and T1 was overall good for cortical structures (mean r across all cortical structures = 0.76). Comparatively weaker results were found in the occipital lobe (r = 0.77), central region (mean r = 0.58), basal ganglia (mean r = 0.59), thalamus (r = 0.30), and cerebellum (r = 0.73). FLAIR segmentation underestimated volume of the central region compared to T1, but showed a better anatomic concordance with the occipital lobe on visual review and subcortical structures, when also compared to manual segmentation. Visual analysis of FLAIR-based WM segmentation revealed frequent misclassification of regions of high signal intensity as GM.

CONCLUSION: Warp-based FLAIR segmentation yields comparable results to T1 segmentation for most cortical GM structures and may provide anatomically more congruent segmentation of subcortical GM structures. Selected cortical regions, especially the central region and total WM, seem to be underestimated on FLAIR segmentation.

来源:Neuroradiology,查看原文。版权归原作者所有。

引用

  1. Beller E, Keeser D, Wehn A, et al. T1-MPRAGE and T2-FLAIR segmentation of cortical and subcortical brain regions-an MRI evaluation study. Neuroradiology. 2018. PMID: 30402744. doi:10.1007/s00234-018-2121-2

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。