指南与共识心血管US

英国与美国超声心动图学会左心室舒张功能评估建议的比较分析

A comparative analysis of British and American Society of Echocardiography recommendations for the assessment of left ventricular diastolic function.
指南 / 共识 · Echo Res Pract · 2018-01-01

研究从数据库提取189例窦性心律、以心力衰竭评估或左心室收缩功能评估为主要指征行经胸超声心动图的患者,分别按英国超声心动图学会与美国超声心动图学会/欧洲心血管影像协会建议评估左心室舒张功能并比较。英国建议判为无法分类者显著多于美国建议(47.4% vs 20.5%,P<0.0001),可分级者中美国建议判为1级者显著更多(40.7% vs 20.1%,P<0.0001)。

要点

  • 英国建议下无法分类的舒张功能比例显著高于美国建议(47.4% vs 20.5%,P<0.0001)。
  • 可分级患者中美国建议判为1级舒张功能的比例显著更高(40.7% vs 20.1%,P<0.0001)。
  • 两套建议对正常与1级舒张功能的分类存在显著差异,报告时需注明所用建议。

核心结论

  • 英国与美国建议对左心室舒张功能的分级结果存在显著差异,英国建议下无法分类者更多、美国建议下1级更多。

研究设计与样本

  • 比较性研究,纳入189例窦性心律、以心力衰竭评估或左心室收缩功能评估为主要指征行经胸超声心动图的患者,数据取自本院McKesson Cardiology数据库,分别按英国超声心动图学会与美国超声心动图学会/欧洲心血管影像协会建议评估并比较,采用卡方检验、Kappa评分和单因素方差分析,检验水准P<0.05。

诊断标准与关键数值

  • 英国建议判为无法分类者占47.4%,美国建议占20.5%(P<0.0001);可分级患者中美国建议判为1级者占40.7%,英国建议占20.1%(P<0.0001)。

临床应用与阅片要点

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

At present there are two recognised guidelines for the echocardiographic assessment of left ventricular diastolic function provided by the British Society of Echocardiography and American Society of Echocardiography/European Association of Cardiovascular Imaging. However, no direct comparison of these guidelines has been performed to establish whether they provide similar diastolic grading. One hundred and eighty-nine consecutive patients in sinus rhythm who underwent transthoracic echocardiography for a primary indication of either heart failure assessment or assessment of left ventricular systolic function were extracted from our database (McKesson Cardiology). Left ventricular diastolic function assessment was performed using both guidelines and the results were compared. Chi-square, Kappa score and one-way ANOVA were used to evaluate the data at a level of P < 0.05. The most frequent outcome was unclassifiable diastolic function with significantly more patients being labelled unclassified with the British compared to American guidelines (47.4 vs 20.5%, P < 0.0001). Having excluded all unclassifiable patients, a significant difference still existed between the two guidelines with a higher proportion of grade one outcomes awarded by the ASE/EACVI guidelines. When grading subcategories were individually compared, there was significantly more grade one diastolic gradings awarded by American compared to the British guidelines (40.7 vs 20.1%, P < 0.0001). In 47% of patients it was not possible to grade diastolic function using the British guidelines, compared to 21% using the American guidelines. For those patients where grading was possible, there was a significant difference in patients classified with normal and grade one diastolic function when using British and American guidelines.

来源:Echo Res Pract,查看原文。版权归原作者所有。