血流相99mTc-红细胞闪烁显像在急性消化道出血中独立预测血管造影结果的效用
回顾性分析145例消化道出血患者的173次闪烁显像,其中42例(29%)闪烁显像阳性,29例接受导管血管造影,6例(21%)见造影剂外溢。血流相闪烁显像预测血管造影外溢的敏感度、特异度、阳性预测值、阴性预测值分别为100%、70%、46%、100%。血流相阴性可识别尽管动态相阳性但不会从导管血管造影获益的患者。
要点
- 血流相闪烁显像阴性时,导管血管造影外溢的阴性预测值为100%。
- 血流相阳性后4小时内行导管血管造影,其特异度和阳性预测值更高。
- 血流相闪烁显像预测导管血管造影外溢的敏感度为100%、特异度为70%。
核心结论
- 血流相闪烁显像阴性可识别尽管动态相闪烁显像阳性但不会从导管血管造影获益的患者;血流相阳性后尽快行导管血管造影发现外溢的可能性更高。
研究设计与样本
- 回顾性研究,经机构审查委员会批准并豁免知情同意,分析2013年1月至2014年8月145例消化道出血患者的173次闪烁显像;闪烁显像分血流相(1帧/秒,共1分钟)和动态相(1帧/30秒,共1小时);评估闪烁显像阳性后24小时内接受导管血管造影的患者;每期图像由两名核医学医师随机独立判读,互盲并对导管血管造影结果盲。
诊断标准与关键数值
- 血流相闪烁显像预测导管血管造影外溢的敏感度100%、特异度70%、阳性预测值46%、阴性预测值100%;血流相阳性后4小时内行导管血管造影时,特异度和阳性预测值更高。
临床应用与阅片要点
- 解读急性消化道出血的99mTc-红细胞闪烁显像时,血流相阴性可提示患者不会从导管血管造影获益,尽管动态相阳性;血流相阳性后行导管血管造影的时机越早,发现外溢的可能性越高。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE:: In acute gastrointestinal bleeding, despite positive dynamic phase 99mTc-red blood cell scintigraphy, invasive catheter angiography (CA) is frequently negative. In this study, we investigated the value of flow phase scintigraphy in predicting extravasation on CA.
METHODS:: Institutional review board approval with a waiver of informed consent was obtained for this retrospective study. A total of 173 scintigraphy procedures performed in 145 patients with GIB between January 2013 and August 2014 were analysed. Scintigraphy had two phases: flow (1 image/s for 1 min) followed by dynamic (1 image/30 s for 1 h). Patients who underwent CA within 24 hours of positive scintigraphy were assessed. Each scintigraphy phase was randomly and independently reviewed by two nuclear medicine physicians blinded to the outcomes of the other phase and of CA.
RESULTS:: A total of 42 patients (29%) had positive scintigraphy. Of these patients, 29 underwent CA, and extravasation was seen in 6 (21%). In all, dynamic phase scintigraphy was positive. 13 of the 29 patients also had positive flow phase scintigraphy. The sensitivity, specificity, positive-predictive value, and negative-predictive value of flow phase scintigraphy for extravasation on CA were 100, 70, 46, and 100%, respectively. Specificity and positive predictive value were higher when CA was performed within 4 hours of positive flow phase scintigraphy.
CONCLUSIONS:: Negative flow phase scintigraphy can identify patients who will not benefit from CA despite positive dynamic phase scintigraphy. The likelihood of extravasation on CA is higher when performed soon after positive flow phase scintigraphy.
ADVANCES IN KNOWLEDGE:: Negative flow phase scintigraphy identifies patients who will not benefit from invasive catheter angiography despite positive results on subsequent dynamic phase scintigraphy. Increasing the delay between positive red blood cell scintigraphy and catheter angiography progressively reduces the likelihood of identifying extravasation, which is required to target embolization.
引用
- Gurajala RK, Fayazzadeh E, Nasr E, et al. Independent usefulness of flow phase 99mTc-red blood cell scintigraphy in predicting the results of angiography in acute gastrointestinal bleeding. Br J Radiol. 2018. PMID: 30307319. doi:10.1259/bjr.20180336
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。