文献速递泌尿生殖儿科影像MR

非对比增强磁共振血管成像检测婴幼儿交叉肾血管:与对比增强血管成像及手术所见对比

Non-contrast-enhanced magnetic resonance angiography for detecting crossing renal vessels in infants and young children: comparison with contrast-enhanced angiography and surgical findings.
PubMed 文献 · Pediatr Radiol · 2018-10-03

回顾性分析29例4岁以下单侧肾积水患儿的术前MR尿路成像,由两名独立阅片者判断有无交叉肾血管并与手术所见比较。非对比增强平衡触发血管成像的敏感度为70%(95%CI:35-93%)、特异度为93%(95%CI:66-100%);对比增强MR血管成像的敏感度为56%(95%CI:21-86%)、特异度为91%(95%CI:59-100%)。作者认为非对比增强MR可能是有别于对比增强MR血管成像的可靠、有效且安全的替代方法。

要点

  • 非对比增强MR血管成像检测交叉肾血管敏感度70%(95%CI:35-93%)、特异度93%(95%CI:66-100%)。
  • 对比增强MR血管成像敏感度56%(95%CI:21-86%)、特异度91%(95%CI:59-100%)。
  • 非对比增强MR与手术所见的不一致率为17%,对比增强MR与手术所见的不一致率为25%。

核心结论

  • 非对比增强MR可能是有别于对比增强MR血管成像的可靠、有效且安全的替代方法,用于识别交叉肾血管。

研究设计与样本

  • 回顾性研究,纳入29例4岁以下单侧肾积水患儿,由两名独立阅片者评估术前MR尿路成像,以手术所见为参考标准。

诊断标准与关键数值

  • 非对比增强平衡触发血管成像检测交叉肾血管:敏感度70%(95%CI:35-93%),特异度93%(95%CI:66-100%)。
  • 对比增强MR血管成像检测交叉肾血管:敏感度56%(95%CI:21-86%),特异度91%(95%CI:59-100%)。
  • 非对比增强MR血管成像与对比增强MR血管成像检测交叉肾血管的不一致率为8%。
  • 非对比增强MR与手术所见的不一致率为17%,对比增强MR血管成像与手术所见的不一致率为25%。

临床应用与阅片要点

  • 作者认为非对比增强MR可能是有别于对比增强MR血管成像的可靠、有效且安全的替代方法。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

BACKGROUND: Knowing that ureteropelvic junction obstruction is due to a crossing renal vessel is essential in choosing the appropriate surgical treatment.

OBJECTIVE: To evaluate the diagnostic accuracy of non-contrast magnetic resonance (MR) angiography in identifying crossing renal vessels in children younger than 4 years old with unilateral hydronephrosis.

MATERIALS AND METHODS: A retrospective review of preoperative MR urography of children with unilateral hydronephrosis was conducted by two independent readers. The presence or absence of crossing renal vessels was identified and compared with surgical findings.

RESULTS: Twenty-nine patients were included. The disagreement between MR angiography with and without contrast enhancement in detecting a crossing renal vessel was 8%. The disagreement between non-contrast-enhanced MR and surgical findings was 17%. The disagreement between contrast-enhanced MR angiography and surgical findings was 25%. The balanced triggered angiography without contrast enhancement had a sensitivity of 70% (95% confidence interval [CI]: 35-93%) and a specificity of 93% (95% CI: 66-100%). Contrast-enhanced MR angiography had a sensitivity of 56% (95% CI: 21-86%) and a specificity of 91%. (95% CI: 59-100%).

CONCLUSION: MR without contrast enhancement may be a reliable, valid and safe alternative to contrast-enhanced MR angiography for identifying crossing renal vessels.

来源:Pediatr Radiol,查看原文。版权归原作者所有。

引用

  1. Sertorio F, Wong MCY, Incarbone V, et al. Non-contrast-enhanced magnetic resonance angiography for detecting crossing renal vessels in infants and young children: comparison with contrast-enhanced angiography and surgical findings. Pediatr Radiol. 2018. PMID: 30284006. doi:10.1007/s00247-018-4252-3

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。