髂腰肌弹响髋:一种新参数提升磁共振成像诊断价值的研究
该回顾性队列研究分析了一位外科医生在2015年1月至2016年3月间所有患者的髋部MRI,比较临床髂腰肌内部弹响综合征患者(48例)与无此症状的对照组(85例)。通过最小强度投影测量骨盆入射角、冠状角和矢状开口角(SOA)。SOA在两组间差异有统计学意义(对照组137.0° vs 对比组141.9°,p<0.01),SOA>140°的比值比为5.2(2.4-11.3),提示SOA具有诊断价值。
要点
- SOA在临床弹响组为141.9°±6.5°,对照组为137.0°±5.9°,差异有统计学意义(p<0.01)。
- 骨盆入射角和冠状角在两组间无显著差异,诊断价值有限。
核心结论
- 矢状开口角(SOA)与临床髂腰肌内部弹响髋相关,SOA>140°具有诊断价值,但髂腰肌弹响髋常是更复杂疾病过程的一部分。
研究设计与样本
- 回顾性队列研究,纳入一位外科医生2015年1月至2016年3月间所有患者的髋部MRI,对照组85例,临床内部弹响组48例,采用最小强度投影处理图像,测量骨盆入射角、冠状角和矢状开口角,使用Mann-Whitney U检验和ROC曲线分析。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE: To illustrate an advanced imaging parameter that describes the course of the iliopsoas tendon, and evaluate its correlations with iliopsoas internal hip snapping syndrome.
METHODS: This retrospective cohort study reviewed hip MRI images of all patients seen by a single surgeon between January 2015 and March 2016. The comparison group included all patients with clinical internal hip snapping, versus the control group that did not. MRI images were processed using minimum intensity projection. Measurements obtained of the pelvis and course of the iliopsoas tendon included: pelvic incidence, coronal angle, and sagittal opening angle (SOA). Comparison of measurements between the groups was performed with Mann-Whitney U analysis and receiver operator curve (ROC) plotting, with a significance cutoff of p = 0.05.
RESULTS: The control group (n = 85) and comparison group (n = 48) demonstrated no difference in age or gender. Pelvic incidence was similar [51.3 (± 10.7) degrees control versus 52.2 (± 7.7) degrees comparison (p = 0.36)], as was coronal angle [13.9 (± 4.6) degrees control versus 14.8 (±4.8) degrees comparison (p = 0.15)]. There was a significant difference in SOA [137.0 (± 5.9) degrees control versus 141.9 (± 6.5) degrees comparison (p < 0.01)]. ROC analysis revealed SOA threshold of 140 degrees for clinical IP hip snapping (p < 0.01), with odds ratio 5.2 (2.4-11.3) for SOA > 140 degrees.
CONCLUSIONS: Iliopsoas hip snapping is often part of a more complex disease process. While challenging to diagnose, advanced imaging parameters, like the sagittal opening angle, relate with clinical pathology. The SOA offers diagnostic value, with a threshold of greater than 140 degrees significantly correlating with clinical presentation.
引用
- Bakhsh W, Childs S, Kenney R, et al. Iliopsoas snapping hip: improving the diagnostic value of magnetic resonance imaging with a novel parameter. Skeletal Radiol. 2018. PMID: 30280202. doi:10.1007/s00256-018-3083-5