颈椎MR临床应用中IDEAL成像的获益与陷阱
研究对100例有症状患者行颈椎常规MRI与IDEAL-FSE成像,比较SNR、CNR、图像质量及退变性脊柱病诊断效能。IDEAL-FSE的SNR和CNR均显著高于FS T2W-FSE(均p<0.001);16例有内固定患者中IDEAL-FSE脂肪抑制均匀性和金属伪影均显著更优(均p<0.001)。作者结论认为T2W IDEAL-FSE仅应作为常规FS T2W图像的附加序列,用于脂肪抑制不佳或金属伪影严重的患者。
要点
- IDEAL-FSE的SNR和CNR显著高于FS T2W-FSE(均p<0.001)。
- 有内固定患者中IDEAL-FSE脂肪抑制更均匀、金属伪影更少(均p<0.001)。
- 无内固定患者中FS T2W-FSE整体图像质量和CSF均匀性更优、运动伪影更少(均p<0.001)。
核心结论
- 作者结论认为T2W IDEAL-FSE成像仅应作为常规FS T2W图像的附加序列,用于脂肪抑制不佳或金属伪影严重的患者。
研究设计与样本
- 对100例有症状患者行颈椎MRI,比较常规MRI与IDEAL-FSE成像,分析SNR、CNR和图像质量,并比较退变性脊柱病的诊断效能。
关键影像表现/征象
- IDEAL-FSE的SNR和CNR显著高于FS T2W-FSE(均p<0.001)。
- 100例中16例有颈椎内固定,该组IDEAL-FSE脂肪抑制均匀性显著更优(p<0.001)且金属伪影显著更少(p<0.001)。
- 无内固定患者中FS T2W-FSE整体图像质量显著更优(p<0.001)、CSF均匀性显著更优(p<0.001)且运动伪影显著更少(p<0.001)。
- 无内固定患者中IDEAL-FSE脂肪抑制均匀性显著更优(p<0.001)。
诊断标准与关键数值
- IDEAL与FS T2W图像对腰椎滑脱、退行性滑脱、椎间盘突出和脊髓型脊椎病的诊断无显著差异。
- IDEAL与FS T2W图像仅在C2-3和C5-6椎间盘退变诊断(分别为p=0.019、p=0.002)及C3椎体骨髓水肿诊断(p=0.029)上存在显著差异。
临床应用与阅片要点
- 作者结论认为T2W IDEAL-FSE成像仅应作为常规FS T2W图像的附加序列,用于脂肪抑制不佳或金属伪影严重的患者。
- 有颈椎内固定患者中IDEAL-FSE脂肪抑制更均匀且金属伪影更少(均p<0.001)。
- 无内固定患者中FS T2W-FSE整体图像质量、CSF均匀性更优且运动伪影更少(均p<0.001)。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
AIM: To evaluate efficacy of T2-weighted (T2W) iterative decomposition of water and fat with echo asymmetry and least-squares estimation (IDEAL)-fast spin echo (FSE) imaging of the cervical spine.
MATERIALS AND METHODS: The cervical spine of 100 symptomatic patients was imaged using routine magnetic resonance imaging (MRI) versus IDEAL-FSE imaging. The signal-to-noise ratios (SNRs), contrast-to-noise ratios (CNRs), and image quality were analysed. To compare the diagnostic efficiency of degenerative spondylopathy, evaluations of spondylolisthesis, retrolisthesis, disc herniation, myelopathy, disc degeneration, and bone marrow oedema were also performed.
RESULTS: IDEAL-FSE showed significantly higher SNRs and CNRs (all p<0.001) than fat-suppressed (FS) T2W-FSE. Sixteen of 100 patients had cervical spine instrumentation; in those patients, IDEAL-FSE provided significantly better uniformity of fat suppression (p<0.001) and fewer metallic artefacts (p<0.001). For patients without instrumentation, FS T2W-FSE showed significantly better overall image quality (p<0.001) and homogeneity of the cerebrospinal fluid (CSF; p<0.001) with fewer motion artefacts (p<0.001). IDEAL-FSE, however, provided significantly better uniformity of fat suppression (p<0.001). There were no significant differences in the diagnoses of spondylolisthesis, retrolisthesis, disc herniation, or myelopathy between IDEAL and FS T2W images. The only significant differences between the IDEAL and FS T2W images were noted when diagnosing degenerative disc disease at the C2-3 and C5-6 disc levels (p=0.019, p=0.002, respectively) and bone marrow oedema at C3 vertebral body (p=0.029).
CONCLUSION: T2W IDEAL-FSE imaging should only be considered as an additional sequence to conventional FS T2W images in patients with poor fat suppression or severe metallic artefacts.
引用
- Chiang IC, Chuang WS, Hang IT, et al. Benefits and pitfalls of iterative decomposition of water and fat with echo asymmetry and least-squares estimation (IDEAL) imaging in clinical application of the cervical spine MR. Clin Radiol. 2018. PMID: 30314808. doi:10.1016/j.crad.2018.09.002
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。