文献速递儿科影像骨肌DR

儿童脊柱侧弯脊柱三维重建的缩减微剂量协议:基于体模和临床验证的立体放射摄影研究

A reduced micro-dose protocol for 3D reconstruction of the spine in children with scoliosis: results of a phantom-based and clinically validated study using stereo-radiography.
PubMed 文献 · Eur Radiol · 2018-10-22

研究在儿童体模上确定可接受脊柱标志可见性的最低剂量,并在18例12岁及以下脊柱侧弯患儿中比较缩减微剂量与微剂量协议的三维重建重复性。缩减微剂量理论辐射剂量降低约58%,观察者内和观察者间重复性可接受(如Cobb角不确定度3.8°),但两种微剂量协议多数参数的重建质量均劣于标准剂量协议。

要点

  • 缩减微剂量协议理论辐射剂量较微剂量降低约58%,可用于轻度脊柱侧弯儿童的初步筛查和随访。
  • 缩减微剂量协议三维重建的观察者内和观察者间重复性可接受,Cobb角不确定度为3.8°。
  • 缩减微剂量与微剂量协议多数参数的三维重建质量均劣于标准剂量协议,标准剂量仍是精确评估的首选。

核心结论

  • 缩减微剂量协议对轻度脊柱侧弯患儿的脊柱三维重建可靠,可提供低辐射的初步筛查和随访工具并可能替代微剂量协议,但多数参数重建质量劣于标准剂量,标准剂量协议仍是精确评估和三维重建的首选。

研究设计与样本

  • 体模研究结合临床验证研究:先对儿童拟人化体模行低剂量双平面放射摄影半定量图像分析以确定最低剂量,再对18例12岁及以下脊柱侧弯患儿行全脊柱双平面放射摄影(微剂量与缩减微剂量),由三名操作者按ISO-5725标准行三维重建的观察者内和观察者间信度研究。

诊断标准与关键数值

  • 缩减微剂量设置对应理论辐射剂量暴露降低约58%。
  • 体内结果显示观察者内和观察者间信度可接受,例如Cobb角不确定度为3.8°。

临床应用与阅片要点

  • 缩减微剂量协议可作为轻度脊柱侧弯儿童的初步筛查选项和随访工具,辐射极低。
  • 缩减微剂量协议可能替代现有微剂量协议用于此类患者。
  • 标准剂量协议仍是大多数情况下最准确评估和三维重建脊柱的首选。

局限性

  • 缩减微剂量与微剂量协议在多数参数上的三维重建质量均劣于标准剂量协议。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: The aim of this study was to validate the reproducibility of 3D reconstructions of the spine using a new reduced micro-dose protocol.

METHODS: First, semi-quantitative image analysis was performed using an anthropomorphic child phantom undergoing low-dose biplanar radiography. This analysis was used to establish a "lowest dose" allowing for acceptable visibility of spinal landmarks. Subsequently, a group of 18 scoliotic children, 12 years of age or younger, underwent full-spine biplanar radiography with both micro-dose and the newly defined reduced micro-dose. An intra- and inter-observer reliability study of 3D reconstructions of the spine was performed according to the International Organization for Standardization (ISO)-5725 standard, with three operators.

RESULTS: The reduced micro-dose setting corresponded to a theoretical reduction of radiation dose exposure of approximately 58%. In vivo results showed acceptable intra- and inter-observer reliability (for instance, 3.8° uncertainty on Cobb angle), comparable to previous studies on 3D spine reconstruction reliability and reproducibility based on stereo-radiography.

CONCLUSION: A new reduced micro-dose protocol offered reliable 3D reconstructions of the spine in patients with mild scoliosis. However, the quality of 3D reconstructions from both reduced micro-dose and micro-dose was inferior to standard-dose protocol on most parameters. Standard-dose protocol remains the option of choice for most accurate assessment and 3D reconstruction of the spine. Still, this new protocol offers a preliminary screening option and a follow-up tool for children with mild scoliosis yielding extremely low radiation and could replace micro-dose protocol for these patients.

KEY POINTS: • We investigated the reliability of 3D reconstructions of the spine based on a new stereo-radiography protocol reducing radiation dose by 58% compared with established micro-dose imaging protocol. • The new reduced micro-dose protocol offers a reproducible preliminary screening option and a follow-up tool in the necessarily frequent repeat imaging of children with mild scoliosis yielding extremely low radiation and could replace existing micro-dose protocol for these patients. • EOS standard-dose protocol remains the option of choice for exact radiographic assessment of scoliosis, offering more exact 3D reproducibility of the spine compared to both micro-dose and the new reduced micro-dose protocols.

来源:Eur Radiol,查看原文。版权归原作者所有。

引用

  1. Pedersen PH, Vergari C, Alzakri A, et al. A reduced micro-dose protocol for 3D reconstruction of the spine in children with scoliosis: results of a phantom-based and clinically validated study using stereo-radiography. Eur Radiol. 2018. PMID: 30350165. doi:10.1007/s00330-018-5749-8

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。