文献速递骨肌CT

Walch B2 与 B3 型肩胛盂的多层面形态及后倾评估

Multilevel glenoid morphology and retroversion assessment in Walch B2 and B3 types.
PubMed 文献 · Skeletal Radiol · 2018-10-17

本研究回顾性分析386例因全肩关节置换术前规划而行的肩关节CT,纳入29例B2型和8例B3型肩胛盂,由两名读者按Friedman法在肩胛盂高度75%、50%、25%三个层面独立测量后倾角;三个层面间方差在B2和B3组均无显著差异,作者推荐以肩胛盂赤道层面作为后倾测量的参考。

要点

  • B2、B3型肩胛盂在高度25%至75%之间各层面均可准确测量后倾角。
  • 三个层面后倾角方差在B2和B3组均无显著差异。
  • 作者推荐以肩胛盂赤道层面作为测量后倾的参考,以保证一致性和可靠性。

核心结论

  • 在Walch B2和B3型肩胛盂中,肩胛盂高度25%至75%之间的任何层面均可准确测量肩胛盂后倾角,作者推荐以肩胛盂赤道层面作为参考以确保测量的一致性和可靠性。

研究设计与样本

  • 研究类型为对386例连续肩关节CT检查的回顾性复习,检查目的为全肩关节置换术前规划;最终纳入29例B2型和8例B3型肩胛盂。
  • 采用经验证的技术重建真轴位CT图像,由两名读者依照Friedman法、以「中间」肩胛盂在肩胛盂高度75%(上部)、50%(赤道)、25%(下部)三个层面独立测量后倾角。
  • 计算同一患者三个层面之间的方差,并评估读者间一致性。

关键影像表现/征象

  • B2型肩胛盂赤道与下部、上部与赤道、上部与下部之间的后倾角度平均方差分别为-0.4、0.3和-0.2。
  • B3型肩胛盂赤道与下部、上部与赤道、上部与下部之间的后倾角度平均方差分别为-0.2、1.9和1.9。
  • B2或B3组内三个层面间的方差均无显著差异。

诊断标准与关键数值

  • 后倾角按Friedman法测量,测量对象为肩胛盂高度75%、50%、25%三个层面的「中间」肩胛盂。
  • 读者间一致性:赤道与下部层面的方差为一般至良好,上部与赤道、上部与下部层面的方差为良好至优秀。

临床应用与阅片要点

  • 作者推荐以肩胛盂赤道层面作为Walch B2和B3型肩胛盂后倾测量的参考,以保证测量的一致性和可靠性。
  • 在高度25%至75%范围内选择测量层面时,各层面测得的后倾角无明显差异,但报告时应注明所采用的参考层面。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: A major factor that impacts the long-term outcome and complication rates of total shoulder arthroplasty is the preoperative posterior glenoid bone loss quantified by glenoid retroversion. The purpose of this study was to assess if glenoid retroversion varies significantly at different glenoid heights in Walch B2 and B3 glenoids.

MATERIALS AND METHODS: Patients with B2 and B3 glenoid types were included following retrospective review of 386 consecutive CT shoulder studies performed for arthroplasty preoperative planning. True axial CT reconstructions were created using a validated technique. Two readers independently measured the glenoid retroversion angles according to the Friedman method using the "intermediate" glenoid at three glenoid heights: 75% (upper), 50% (equator), and 25% (lower). The variances between the three levels for a given patient were calculated.

RESULTS: Twenty-nine B2 and 8 B3 glenoid types were included. There was no significant difference in variance of glenoid version among the three levels in B2 or B3 groups. The mean variance in retroversion degree between equator-lower, upper-equator, and upper-lower glenoid was - 0.4, 0.3, and - 0.2 for B2; and - 0.2, 1.9, and 1.9 for B3 glenoid, respectively. The level of inter-reader agreement was fair to good for variance at equator-lower, and good to excellent for upper-equator and upper-lower glenoid.

CONCLUSIONS: Glenoid version can be accurately measured at any level between 25 and 75% of glenoid height for Walch B2 and B3. We recommend that the glenoid equator be used as the reference to assure consistent and reliable version measurements in this group of patients.

来源:Skeletal Radiol,查看原文。版权归原作者所有。

引用

  1. Samim M, Virk M, Mai D, et al. Multilevel glenoid morphology and retroversion assessment in Walch B2 and B3 types. Skeletal Radiol. 2018. PMID: 30328484. doi:10.1007/s00256-018-3095-1

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。