文献速递甲状腺与浅表头颈US

超声甲状腺结节计算机辅助诊断系统:基于操作者经验水平的诊断性能与可重复性

Computer-aided diagnosis system for thyroid nodules on ultrasonography: diagnostic performance and reproducibility based on the experience level of operators.
PubMed 文献 · Eur Radiol · 2018-10-22

前瞻性纳入2016年7月至10月76例患者共100个甲状腺结节(≥1.0 cm),评估实时CAD系统诊断甲状腺癌的性能与可重复性。CAD系统敏感度88.6%、特异度83.9%、准确率86.0%,敏感度和准确率与有经验放射科医师无显著差异,但特异度较低(83.9% vs 96.4%,p=0.016)。经验较少操作者使用CAD的敏感度和准确率低于有经验放射科医师,观察者间一致性对最终诊断和多数超声描述词为中等(substantial),对边缘和组成为中等(moderate)。

要点

  • CAD系统诊断甲状腺癌敏感度88.6%、特异度83.9%、准确率86.0%,敏感度和准确率与有经验放射科医师无显著差异。
  • 有经验放射科医师特异度显著高于CAD系统(96.4% vs 83.9%,p=0.016)。
  • CAD诊断性能随操作者经验变化,经验较少操作者敏感度70.5-88.6%、准确率72.0-86.0%,低于有经验放射科医师。

核心结论

  • CAD系统可能对甲状腺癌诊断有潜在作用,但操作者依赖性仍然存在,需要改进。

研究设计与样本

  • 前瞻性研究,2016年7月至2016年10月连续纳入76例患者共100个甲状腺结节(≥1.0 cm);由一名有经验放射科医师使用整合于超声机的实时CAD系统进行检查,三名不同超声经验水平(0-5年)的操作者独立应用CAD系统;比较基于操作者经验的CAD诊断性能,并计算癌症诊断及各超声描述词的观察者间一致性。

诊断标准与关键数值

  • CAD系统诊断甲状腺癌的敏感度88.6%、特异度83.9%、阳性预测值81.3%、阴性预测值90.4%、准确率86.0%。
  • CAD系统敏感度和准确率与放射科医师无显著差异(p>0.05),特异度低于有经验放射科医师(83.9% vs 96.4%,p=0.016)。
  • 经验较少操作者使用CAD的敏感度68.8-73.8%、特异度74.1-88.5%、阳性预测值68.9-73.3%、阴性预测值72.7-80.0%、准确率71.0-75.0%。
  • 最终诊断及各超声描述词的观察者间一致性为中等(substantial),边缘和组成为中等(moderate)。

临床应用与阅片要点

  • CAD系统诊断甲状腺癌的敏感度和准确率与有经验放射科医师无显著差异,但特异度较低。
  • CAD系统诊断性能依赖操作者经验,经验较少操作者使用CAD的敏感度和准确率低于有经验放射科医师。

局限性

  • 操作者依赖性仍然存在,需要改进。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: To evaluate the diagnostic performance and reproducibility of a computer-aided diagnosis (CAD) system for thyroid cancer diagnosis using ultrasonography (US) based on the operator's experience.

MATERIALS AND METHODS: Between July 2016 and October 2016, 76 consecutive patients with 100 thyroid nodules (≥ 1.0 cm) were prospectively included. An experienced radiologist performed the US examinations with a real-time CAD system integrated into the US machine, and three operators with different levels of US experience (0-5 years) independently applied the CAD system. We compared the diagnostic performance of the CAD system based on the operators' experience and calculated the interobserver agreement for cancer diagnosis and in terms of each US descriptor.

RESULTS: The sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and accuracy of the CAD system were 88.6, 83.9, 81.3, 90.4, and 86.0%, respectively. The sensitivity and accuracy of the CAD system were not significantly different from those of the radiologist (p > 0.05), while the specificity was higher for the experienced radiologist (p = 0.016). For the less-experienced operators, the sensitivity was 68.8-73.8%, specificity 74.1-88.5%, PPV 68.9-73.3%, NPV 72.7-80.0%, and accuracy 71.0-75.0%. The less-experienced operators showed lower sensitivity and accuracy than those for the experienced radiologist. The interobserver agreement was substantial for the final diagnosis and each US descriptor, and moderate for the margin and composition.

CONCLUSIONS: The CAD system may have a potential role in the thyroid cancer diagnosis. However, operator dependency still remains and needs improvement.

KEY POINTS: • The sensitivity and accuracy of the CAD system did not differ significantly from those of the experienced radiologist (88.6% vs. 84.1%, p = 0.687; 86.0% vs. 91.0%, p = 0.267) while the specificity was significantly higher for the experienced radiologist (83.9% vs. 96.4%, p = 0.016). • However, the diagnostic performance varied according to the operator's experience (sensitivity 70.5-88.6%, accuracy 72.0-86.0%) and they were lower for the less-experienced operators than for the experienced radiologist. • The interobserver agreement was substantial for the final diagnosis and each US descriptor and moderate for the margin and composition.

来源:Eur Radiol,查看原文。版权归原作者所有。

引用

  1. Jeong EY, Kim HL, Ha EJ, et al. Computer-aided diagnosis system for thyroid nodules on ultrasonography: diagnostic performance and reproducibility based on the experience level of operators. Eur Radiol. 2018. PMID: 30350161. doi:10.1007/s00330-018-5772-9

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。