文献速递乳腺US

对比增强超声相对于常规超声在鉴别乳腺良恶性实性病变中的附加价值:系统评价与Meta分析

The added value of contrast-enhanced ultrasound to conventional ultrasound in differentiating benign and malignant solid breast lesions: a systematic review and meta-analysis.
PubMed 文献 · Clin Radiol · 2018-07-06

该系统评价与Meta分析纳入5项研究共992例患者,评估在常规超声基础上加做对比增强超声(CEUS)对乳腺良恶性实性病变的鉴别诊断价值,参考标准为组织病理学。常规超声汇总敏感度0.87、特异度0.80、AUC 0.9049;加做CEUS后汇总敏感度0.93、特异度0.87、AUC 0.9482。Meta回归显示两种方法敏感度无显著差异(p=0.29),特异度差异有统计学意义(p<0.01)。

要点

  • 常规超声加做CEUS后汇总特异度由0.80升至0.87,敏感度由0.87升至0.93。
  • 常规超声AUC 0.9049,加做CEUS后AUC 0.9482。
  • Meta回归示敏感度差异无统计学意义(p=0.29),特异度差异有统计学意义(p<0.01)。

核心结论

  • 在常规超声基础上加做CEUS可提高鉴别乳腺良恶性实性病变的诊断效能,同时保持高敏感度,尤其在BI-RADS 3-5类病变中。

研究设计与样本

  • 系统评价与Meta分析,检索PubMed、EMBASE和Web of Science于2005年5月24日至2017年10月29日发表的相关研究,纳入将CEUS加入常规超声的研究,参考标准为组织病理学 findings,采用QUADAS工具评估纳入研究质量,Meta-Disc 1.4计算敏感度、特异度、sROC曲线和AUC,Stata 12.0行Meta回归比较两种技术的诊断准确率;共纳入5项研究、992例患者。

诊断标准与关键数值

  • 常规超声汇总敏感度0.87(95%CI 0.84-0.91)、特异度0.80(95%CI 0.76-0.84)、AUC 0.9049;加做CEUS后汇总敏感度0.93(95%CI 0.90-0.95)、特异度0.87(95%CI 0.84-0.90)、AUC 0.9482。

临床应用与阅片要点

  • 原文结论认为在常规超声基础上加做CEUS可提高鉴别乳腺良恶性实性病变的诊断效能,同时保持高敏感度,尤其在BI-RADS 3-5类病变中;原文并提出可能需要统一的良恶性鉴别标准以进一步临床应用。

局限性

  • 两种评估方法的敏感度和特异度均存在研究间异质性证据。
  • 原文结论提出可能需要统一的良恶性鉴别标准以进一步临床应用。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

AIM: To investigate the added value of contrast-enhanced ultrasound (CEUS) to the conventional ultrasound (US) in the diagnosis of breast lesions.

MATERIALS AND METHODS: PubMed, EMBASE, and Web of Science were searched for relevant studies published between 24 May 2005, and 29 October 2017. Studies incorporating CEUS into the conventional US were included. The reference standard was set by means of histopathological findings. The quality assessment of diagnostic studies (QUADAS) instrument was used to assess the quality of the included studies. Meta-Disc version 1.4. was used to calculate the sensitivity, specificity, summary receiver-operating characteristic (sROC) curves, and area under the curve (AUC). Meta-regression with Stata 12.0 was used to compare the diagnostic accuracy of the two techniques.

RESULTS: Five studies, comprising 992 patients, were eligible for this meta-analysis. For conventional US, the pooled sensitivity and specificity for were 0.87 (95% confidence interval [CI]: 0.84-0.91) and 0.80 (95% CI: 0.76-0.84), respectively, the AUC was 0.9049. For CEUS-rerated US, the pooled sensitivity and specificity were 0.93 (95% CI: 0.90-0.95) and 0.87 (95% CI: 0.84-0.90). The AUC was 0.9482. Meta-regression showed the sensitivity of CEUS-rerated US did not differ from conventional US (p=0.29), while specificity showed significant difference (p<0.01). There was evidence of between-study heterogeneity regarding sensitivity and specificity for both assessments.

CONCLUSIONS: Adding CEUS to conventional US could improve the diagnostic performance in differentiating benign from malignant solid breast lesions, whilst retaining high sensitivity, especially in Breast Imaging-Reporting and Data System (BI-RADS) 3-5 lesions. A uniform standard to distinguish benign from malignant lesions might be needed for further clinical application.

来源:Clin Radiol,查看原文。版权归原作者所有。