文献速递乳腺乳腺X线

合成二维乳腺X线摄影可替代数字乳腺X线摄影作为广角数字乳腺断层摄影的辅助手段

Synthetic 2-Dimensional Mammography Can Replace Digital Mammography as an Adjunct to Wide-Angle Digital Breast Tomosynthesis.
PubMed 文献 · Invest Radiol · 2019-01-01

该回顾性阅片研究纳入205例女性共179个病灶,比较单独二维数字乳腺X线摄影(DM)、DM联合广角数字乳腺断层摄影(WA-DBT)以及合成二维乳腺X线摄影(SM)联合WA-DBT三种方案的检出率和诊断性能。结果显示联合DBT时敏感度和准确度显著提高且特异度无显著差异,SM与DM联合WA-DBT的阅读结果无差异,作者认为联合WA-DBT阅读时SM应替代DM。

要点

  • 联合广角DBT时敏感度和准确度显著高于单独DM(P<0.001),特异度无显著差异。
  • SM联合WA-DBT与DM联合WA-DBT在敏感度、特异度和准确度上均无显著差异(P≥0.341)。
  • 作者结论认为联合WA-DBT阅读时SM应替代DM。

核心结论

  • 与单独DM相比,广角DBT联合DM或SM可提高敏感度和准确度而不降低特异度;联合WA-DBT阅读时SM与DM无差异,因此SM应替代DM用于联合WA-DBT阅读。

研究设计与样本

  • 回顾性阅片研究,纳入205例女性共179个病灶,患者于2015年3月至6月接受双侧两视角DM和WA-DBT检查。

诊断标准与关键数值

  • 检出率:单独DM为68.7%至79.9%,DM联合WA-DBT为76.5%至84.4%,SM联合WA-DBT为73.2%至84.9%。
  • 敏感度:联合DBT时显著高于单独DM(P<0.001)。
  • 准确度:联合DBT时显著高于单独DM(P<0.001)。
  • 特异度:单独DM、DM联合WA-DBT、SM联合WA-DBT三组间无显著差异(P≥0.846)。
  • SM联合WA-DBT与DM联合WA-DBT在敏感度、特异度和准确度上无显著差异(P≥0.341)。

临床应用与阅片要点

  • 作者结论认为联合WA-DBT阅读时SM应替代DM。
  • 阅片者信心和图像质量评为良好至优秀。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: The aim of this study was to evaluate the detection rate and diagnostic performance of 2-dimensional synthetic mammography (SM) as an adjunct to wide-angle digital breast tomosynthesis (WA-DBT) compared with digital mammography (DM) alone or to DM in combination with WA-DBT.

MATERIALS AND METHODS: There were 205 women with 179 lesions included in this retrospective reader study. Patients underwent bilateral, 2-view (2v) DM and WA-DBT between March and June 2015. The standard of reference was histology and/or 1-year stability at follow-up. Four blinded readers randomly evaluated images according to the BI-RADS lexicon from 3 different protocols: 2v DM alone, 2v DM with 2v WA-DBT, and 2v SM with 2v WA-DBT. Detection rate, sensitivity, specificity, and accuracy were calculated and compared using multivariate analysis. Readers' confidence and image quality were evaluated.

RESULTS: The detection rate ranged from 68.7% to 79.9% for DM, 76.5% to 84.4% for DM with WA-DBT, and 73.2% to 84.9% for SM with WA-DBT. Sensitivity and accuracy were significantly higher when DBT was available (P < 0.001). Specificity did not differ significantly between DM only, DM with WA-DBT, or SM with WA-DBT (P ≥ 0.846). Wide-angle DBT combined readings did not differ between SM and DM in terms of sensitivity, specificity, and accuracy (P ≥ 0.341). Readers' confidence and image quality was rated good to excellent.

CONCLUSIONS: Wide-angle DBT combined with DM or SM increases sensitivity and accuracy without reducing specificity compared with DM alone. Wide-angle DBT combined readings did not differ between SM and DM; therefore, SM should replace DM for combined readings with WA-DBT.

来源:Invest Radiol,查看原文。版权归原作者所有。

引用

  1. Clauser P, Baltzer PAT, Kapetas P, et al. Synthetic 2-Dimensional Mammography Can Replace Digital Mammography as an Adjunct to Wide-Angle Digital Breast Tomosynthesis. Invest Radiol. 2019. PMID: 30281557. doi:10.1097/RLI.0000000000000513