文献速递乳腺US

良性病变评估:乳腺剪切波弹性成像中导致「硬环征」的因素

Benign lesion evaluation: Factors causing the "stiff rim" sign in breast tissues using shear-wave elastography.
PubMed 文献 · Br J Radiol · 2018-11-01

该回顾性研究纳入907例患者的907个乳腺病灶,均行传统超声与剪切波弹性成像,分析良性病灶出现「硬环征」的相关因素。单因素分析显示年龄、深度、形态、边缘、内部成分、CDFI、钙化及病理类型在有无「硬环征」的良性病灶间有显著差异;多因素分析显示CDFI、边缘、内部成分、深度及年龄与良性病灶的「硬环征」显著相关,而病理、形态及钙化与之无相关性。作者认为「硬环征」有助于鉴别良恶性病变。

要点

  • 良性乳腺病灶出现「硬环征」时,阳性CDFI、边缘欠清、内部成分不均、位置较深及年龄较大与「硬环征」显著相关。
  • 病理类型、形态及钙化在多因素分析中与良性病灶的「硬环征」无显著相关。
  • 作者建议对年龄较大、病灶较深、边缘欠清、内部不均且CDFI阳性的「硬环征」良性肿块更仔细检查,以避免不必要的假阳性。

核心结论

  • 「硬环征」有助于鉴别乳腺良恶性病变。
  • 阳性CDFI、边缘欠清、内部成分不均、位置较深及年龄较大与良性乳腺病灶的「硬环征」显著相关。
  • 多因素分析显示病理类型、形态及钙化与良性病灶的「硬环征」无显著相关。
  • 作者认为,年龄较大、良性肿块位置较深、边缘欠清、内部不均且CDFI阳性的「硬环征」患者应更仔细检查,以避免不必要的假阳性。

研究设计与样本

  • 回顾性研究,纳入907例患者的907个病灶,均行传统超声与剪切波弹性成像。
  • 观察并计算患者年龄、最大径、深度、距离、回声、形态、边界、边缘、内部成分、CDFI、钙化、回声衰减及病灶纵向生长,行单因素和多因素分析。

关键影像表现/征象

  • 良性病灶中有「硬环征」与无「硬环征」者在年龄、深度、形态、边缘、内部成分、CDFI、钙化及病理类型上差异有统计学意义。
  • 「硬环征」与病灶最大径、距离、边界、回声、回声衰减及纵向生长无相关性。

诊断标准与关键数值

  • 多因素分析显示CDFI、边缘、内部成分、深度及年龄与良性乳腺病灶的「硬环征」显著相关。
  • 多因素分析显示病理类型、形态及钙化与良性乳腺病灶的「硬环征」无相关性。

临床应用与阅片要点

  • 阅片遇良性乳腺病灶出现「硬环征」时,需结合CDFI、边缘、内部成分、深度及患者年龄综合判断。
  • 作者建议对年龄较大、位置较深、边缘欠清、内部不均且CDFI阳性的「硬环征」良性肿块更仔细检查,以避免不必要的假阳性。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE:: To investigate the factors causing the "stiff rim" sign in breast lesions using shear-wave elastography.

METHODS:: A total of 907 patients with 907 lesions were included retrospectively in this study. Traditional ultrasound and shear-wave elastography imaging were both performed. Patients age, maximum diameter, depth, distance, echogenicity, shape, boundary, margin, internal components, CDFI, calcification, echogenicity attenuation and longitudinal growth of lesions were observed and calculated by both univariate and multivariate analyses.

RESULTS:: Univariate analyses indicated that the age, depth, shape, margin, internal components, CDFI, calcification and pathology showed significant difference between the benign lesions with and without a "stiff rim", whereas there was no correlation of "stiff rim" with maximum diameter, distance, boundary, echogenicity, echo attenuation and longitudinal growth of the lesions. Multivariate analysis expressed that CDFI, margin, internal components, depth and age were significantly associated with the "stiff rim" sign in breast benign lesions, whereas there was no correlation with the pathology, shape or calcification of the lesions.

CONCLUSIONS:: The "stiff rim" sign can be helpful for differentiation between benign and malignant lesions. Older patients with a "stiff rim" sign whose benign masses are deep, poorly defined, heterogeneous and have a positive CDFI should be examined more closely to avoid unnecessary false-positives.

ADVANCES IN KNOWLEDGE:: The "stiff rim" sign can be helpful for differentiation between benign and malignant lesions. Positive CDFI, poorly defined margin, heterogeneous internal components, deep depth and older age were significantly associated with the "stiff rim" sign in benign breast lesions.

来源:Br J Radiol,查看原文。版权归原作者所有。

引用

  1. Xiang L, Ma F, Yao M, et al. Benign lesion evaluation: Factors causing the "stiff rim" sign in breast tissues using shear-wave elastography. Br J Radiol. 2018. PMID: 30303694. doi:10.1259/bjr.20180602

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。